Loading...
HomeMy WebLinkAbout5395GARF7ELD COUNTY BUILDING, SANITATION and PLANNING.DEPARTMENT 109 8th Strcct Suite 103 Glenwood Springs, Colorado 81601 (303) 945-8212 No. 5395 Job .Addres~ .0175 Dolores Circle, Westbank Mesa, Lot 6, Glenwood Springs NatureofWork ___ B=u"'i"'l"'d"i°'n"'g,_P=-=e-=r.::m:..:i:..:t'--------------------------- Use ofBuilding_ _ _c_:S_i.:.n:0ogo:l.::e:__F_a.:.m.:.i..:.· l:::y'--Dw'--.:.e.:.l.:.l_i.:.n::::g~_w..:./.:.T:...r_i_:p.:.l:_e:__.G_a:_r:_a:_g'.:.e::._ ___________ _ Owncr ______ W~i~l~l~i~a~m"=cE~.,,..';S~t~e~e~l~e,,__ ________________________ _ c cw t/?e'JY' c:vv If Coatractor ____ ~R~~!!n~R~o:!'.b~e~Y!1':!:B".''~t;;~o~n::0~t=r~11:=o~t:'.i~o:!p,~!La'/<:'.'..!'"-::!Y~'l'~J"C_P<A!~~_!,.B.~/~4LS2!..-/!:!;{_ ________ _ Amount of Pcnnil s_~l~3~2:..:0:..:•:..:8:..:2'-------­ Permi t: Plan Paid $524.88 11-4-94 800. 50 520.32 Datc __ ...:D::.e::.c::.e=m=b::.e::.r::....c·::.2.::l.!.,-"1..:9..:9.:.4'------- S. Archuleta Clerk 1 GARFIELD COUNTY APPLICATION FOR BUILDING PERMIT _,, /'/, / PERMIT NUMBER :J 3z ~ please print or type DATE } J • S · 'If /2-2/-<Jf- TO BE FILLED OUT BY APPLICANT 0/1 ---ADDRESS La-r-· " D•l-•llt!:r. ci1ct..E: SUBDIVISIONU) !fS"f°"i''SA Al(' JIY'i Y:SA FILING # LOT # * td BLOCK # TAX SCHEDULE # LEGAL (SEC/TWN/RNG) ------------ "' NANE N Al1E L'C'~:V Iv ADDRESS t1e.f!SA1 "'« /31u 5~ CITY t'?Lot,1 .. 1111' IPHONE Cl"/'% ;(:;i q {) LICENSE # CLASS OF WOPJZ !/Ef1 )(_ ALTERATION ADDITION DEMOLISJi REPAIR ----MOVE ----- NOBILE HOME (make/I'lodel) S .F. OF BUILDING .3 <M-0 S .F. OF LOT ),$3 t.e. # OF FLOORS HEIGHT ------ # OF FANILY UNITS # OF BEDROOMS ~$,.__ __ INTENDED USE OF BUILDING lf'.,;$10r0Jt:/,rf. GARAGE: SINGLE DBL;3 CARPORT: SINGLE_ DBL FIREPLACE ,n I 0 c ,dl,A,11 e..: c.,.,s ) DOCUMENTS ATTACHED WATER SUPPLY ------------------ p RIVE WAY PERNIT ---------------~ SITE PLAN BUILDING PLANS -~X~-~2=~$=c~'f~S:~------- SANITARY SEWER CLEARANCE ON SITE SEWAGE DISPOSAL PERMIT ? ~-~------0 THE R DOCUMENTS (specify) ....------------ PERMIT FEE TOTAL FEE _,.,.._..._,,,co='-"'-= ZONING DISTRICT TYPE OF OCCUPANC-Y--fl~.-,~.,--J'1=~.~,------- TYPE OF CONSTRUCTION · "7 IL.. /ti S .F. OF BUILDING :JTS"O S .F. OhOT MAX. HEIGHT / 1j= • -'.. ROAD CLASS. ---- SETBACKS FROM PROPERTY LINE: FRONT .., /'fJ ' REAR R -1f=' RIGHT fl • 62 'LEFT$ -&• • OFF STREET PARKING SPACES REQUIRED l?LOT PLAN NOTE: Sha easements, property line dimensions, all other structures, specify north, and street name. For odd shaped l_ots, or if. space is too smal.1, provide separate plot plan. # OF BUILDINGS NOW ON PARCEL r\)t?I!)¢'. USE OF BUILDINGS NOW ON PARCEL -------- 12'1, ~.,. ,, IS"· l't-: I~ Oii'/. or' / l~S", 3 ''·~O I hereby acknowledge that I have read this application and the above is correct and I comply with all county ordinances laws regulating building construction SIGNATURE USE ONLY FLOOD HAZARD CERTIFIED BLDG ELEVATION SPECIAL CONDITIONS PROBLEMS WITH PERMIT -----------~ ADDITIONAL INFORMATION NEEDED -------- CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR OR ENGINEER ~,------·---------~ DATE -r ... GARFIELD COUNTY BUILDING AND PLANNING MINIMUM APPLICATION REQUIREMENTS for SINGLE FAMILY DWELLING CONSTRUCTION including NEW CONSTRUCTION ADDITIONS ALTERA TIO NS and MOVED BUILDINGS In order to understand the scope of the work intended under a permit application and expedite the issuance of a permit it is important that complete information be provided. Adequate ,and complete information will prevent delays in the plan review process. Reviewing a plan and the discovery that required information has not been provided by the applicant may result in the delay of the permit issuance and in proceeding with building construction. The owner or contractor may be required to provide this information before the plan review may proceed. This causes delays because other plans that are in line for review may be given attention before the new information may be reviewed after it has been provided to the Building Department. Please review this document to determine if.you have enough information to design your project and provide adequate information to facilitate a plan review. If you do not, it may be helpful to obtain a book titled ''Dwelling construction under the Uniform Building Code. This book is available to you through this department at our cost. Also, please consider using a design professional for assistance in your design and a construction professional for construction of your project. To provide for a more understandable plan in order to determine compliance with the building, plumbing and mechanical codes, applicants are requested to review the following check list prior to and during design. Applicants are required to indicate appropriately and to submit completed check list at time of application for a permit: 1 1. Is a site plan included that indicates the distance of the proposed building or addition to property lines, other buildings, set back easements and utility easements? Yes _$.E._ No -~--eo Not necessary for this project ____ m 2. Does the site plan include the location of the l.S.D.S. (Individual Sewage Disposal System) and the distances to property lines, wells (on subject property and adjacent properties) , streams or water courses? Yes _K__ No ____ eo Not necessary for this project ____ e,, 3. Does the site plan indicate the location and direction of the County or private road accessing the property? Yes_}.__ No _____ e11 Not necessary for this project ____ e21 4. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing steel in accordance with the uniform building code or per stamped engineered design? Yes~--No _____ ell Not necessary for this project _____ e21 S. Do the plans indicate the location and stze of ventilation openings for under floor crawl spaces and the clearances required between wood and earth? Yes ____ No _x __ u1 Not necessary for this project ___ !21 6. r>o the plans indicate th~ size an location of ventilation openings for the a!tjc, roof joist..!E_aces and soffits? Yes _ts.._ No~~_e11 Not necessary for this project ____ e21 7. Do the plans include design loads as required under the Uniform Building code for roof snow loads, ( a minimum of 40 pounds per square foot in Garfield County) floor loads and wind loads? Yes..>-(._ No .__ell Not necessary for this project _____ c21 8. ' Does the plan include a building section drawing indicating foundation, wall, floor and roof construction? Yes L_ No -----<ll Not necessary for this project ____ c21 9. Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists, roof rafters or joists or trusses? Yes l.<..--No Jl._u1 Not necessary for this project _____ a1 10. Does the building section drawing or other detail include the method of positive connection of all columns and beams? 2 Yes::i__ No ____ 01 Not necessary for this project ____ 121 11. Does the plan indicate th"e height of the building or proposed addition from the highest point of the building or addition measured at mid span between the ridge and the eave down to existing grade contours? Yes .L___ No _____ 1l1 Not necessary for this project _____ 121 12. Does the plan include any stove or zero clearance fireplace planned for installation including make and model and Colorado Phase II certifications or phase II EPA certification? Yes ____ No -~-(11 Not necessary for this project ..L..121 13. Does the plan include a masonry fireplace including a fireplace section indicating design to comply with the Uniform Building Code Chapter 37? Yes _____ No _Lui Not necessary for this project -2(, __ m 14. Does the plan include a' window schedule or other verification that egress/rescue windows from sleeping rooms and/or basements comply with the requirements of the Uniform Building Code? Yes-----No -X-01 Not necessary for this project ___ m 15. Does the plan include a window schedule or other verification that windows provide natural light and ventilation for all habitable rooms? Yes _x__ No _____ 01 Not necessary for this project _____ m 16. Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking surface; sliding glass doors: fixed glass panels; shower doors and tub enclosures and specify safety glazing for these areas? Yes____ No _x __ 111 Not necessary for this project _____ m 17. Is the location of all natural and liquid petroleum gas furnaces, boil~~ and water heaters indicated on the plan? Yes ..A,__ No _____ 1l1 Not necessary for this project _____ 121 18. Have two (2) complete sets of constructions drawings been submitted with the application? Yes _x__ No _____ ill Not necessary for this project ____ 121 19. Have you designed or had this plan designed while considering buil<\.ing and other construction code requirements? Yes .)5...__ No ____ 131 3 .... --. , , . . 20. Does the plan accurately indicate what you intend to construct and what will receive a final inspection by the Garfield Building Depanment? · Yes _x__ No _____ (3) 21. Do you understand that approval for design and/or construction chan~es are required prior to the application of these changes? Yes _)L_ No -----<3J 22. Do you understand that the Building Department will collect a "Plan Review" fee from you at the time of application and that you will be required to pay the "Permit Fee" as well as any "School impact" or "Septic system " fees required, at the time you pick up your building permit? Yes _4_ No -----<3J 23. Are you aware that you are required to call for all inspections required under the Uniform Building Code including approval on a final inspection prior to receiving a Certificate of Occupancy and ocCUJ?~ncy of the building? Yes _,2S.__ No -----"1 24. Are you aware that the person signing the Permit Application whether the "Owner", "Agent of the Owner", "General Contractor", "Contractor" or otherwise, signing the application is the party responsible for the project complying with the Uniform Codes". Yes _x_ No ----<3; I hereby acknowledge that I have read, understand and answered these questions ccurately to the best of my ability .. signature //. J~qf date Phone: 0-1~· f".)._tf" (days); _q~4~{~·~·f.~:.;.~:;;.._& __ (evenings) Project Name: ~::S~~-P'_C'_J._~_~m~IE'~:s~' o~"~ll~!_c..~i::-__________ _ Project Address: L D-<' IA} lts\MAI K /YJ E" .s A. 4 .. ...,., Notes: (I) If you have answered "No" on any or these questions you may be required to provide this information at the request of the Bulldlng Official prior to beginning the plan review process. Delays In Issuing the permit are to be expected. Work may not proceed without the issuance of the permit. (2) If you have answered "Not necessary for this project" on any of the questions and It Is determined by the Building Official that the Information Is necessary to review the applJcatlon and plarts to determine minimum compliance with the adopted codes, please expect the following: A. The application may be placed behind more recent applications for building permits In the review process and not reviewed until required Information has been provided and the application rotates again to first position for review. B. Delay In Issuance of the permit. C. Delay Jn proceeding with construction. (3) If you answered "No" to this question the circumstances described in the question could result In a •stop Work Order" being issued or a "Cer~iflcate of Occupancy" not ~eing lssued. PerAppOl.94 Effective May I, 1994 s ·~ti\#1,v ~ WU1il wi~il.al.. ilU I .. ~ a1•1i1&1&; Unli.!L;,ff 0~ . THIS CARD IS POSTED ON THE JOB 24 HOURS NOTICE REQUIRED FOR INSPECTIONS BUILDING PERMIT GA IELD COUNTY, COLORADO D"' , .. ,.12.f l ··· "/:oo•d A":GREEMEN; m P"mit No . .23.lS mm ' In consideration of the issuanc<! of this permit, the applicant hereby agree~ to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and constructi of the above. d7f ibed structure, the permit may then be revoked. by notice e:m . din' ftor di~ I ELYB e_o UL DeD, 07 Setbacks Front Side This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection. INSPECTION RECORD Zoning Roof Covering :fe . fi;· + /'f-"?c'-)<f-2,~ Electric-Final (by STATE inspector) , k!f',~·"7Z ~ F ootmg / «7. ") <;"" · ,;,7 ..___, ;;'::\{ 11{ //-7-9S Foundation 2 n'c;"7 ZJ~:~ · :f;-!;,~'/"tftu'L- . u "'""'"'~"//'$YT Plumbmg-nderground 'l/'llrs <r""'-6' Gas Piping 7/7/r..-Heating Ventilation Frame 7-:Z? -'? S" -~0"11. / Insulation 7-.3 J-'T £"" ';.;./::, ., Plumbing-Rough Z/'J"fS ;JM:£ Drywall 9/=lfs" J'A.t.e . Electric-Rough S' ;?...,'-L-- (by STATE inspector) 7 v_~.' (_I-CI \ Final 11~7 'J'-')"" ( ~ '\_v1 ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 10 9 8th Street, County Courthouse, Glen''l'OOd Springs, Colo. Certificate Of Occupancy No. 2669 I )"io change in the character of occupancy of a / building shall be made 'vithout a Certificate of Occupancy -(UBC Sec. 502) Building Department Garfield County, Colorado This certificate is issued pursuant to the requirements of Section 307 of the Uniform Building Code certifying that at the time of issuance, this structure was in compliance with the various codes adopted by the County regulating building construction or use for the following: Use Classification Single Family Dwelling w/Triple Garage B .1d. p . N 5395 U1 mg enmt o. _______ _ Zone District ----- R-3, M-1 Type of Construction ___ v_-_N ______ _ Group Owner ofBuildincr William E. Steele o----,----'-_.::__.::_::..::_ ______ _ A.ddress P.O. Box 1507, Glenwood Springs, co Buildincr A.ddress 0175 Dolores Circle, Glenwood Springs, CO 0 Locality West bank Mesa, Lot 6 Contractor Owner Address same ------ By ~~ Chief Building Official · Date November 9 1995 Issuance of a Certificate of Occupancy shall not be construed as au approval of the provision of this code or of other ordinances of the jurisdiction. Certificated presuming to give authority to violate or cancel the provisions of this code or of "J I other ordinances of the jurisdiction shall not be valid. (UBC Sec. 307(a)). 1\