GARFIELD COUNTY
BUILDING, SANITATION and PLANNING DEPARTMENT
' .. 109 8th Streat Sulla 3o3
Glenwood Springs, .Colorado 81601
(303) 945-8212
JobAddress _____ 14_9-:-1_3_H_1..;:;g:..:li_w_a.:_y_82_.:_•_',R.,..a_•_c_h-:a_t_B.o_:_ar_i.._ng...::.._F_:o_r_k~,_:_Ca_r::_b_o:..:n:..:d:..:a_::l_::e ___ _:_~----
Nature of Work Bu1lding Permit
Use of Building ---~R".'e"'nn=d:.::e':l'-W"-o':"r~k::....:•:.;t:......:U:.=n:=i:.=t-=2::.5::.1 __ ~-------------------
0wner _______ }_la_:r_:t_a_:_:S::u=n=d::;be,::.::_r~g-----,---------:------------------
Contractor _____ R_i--'c'-'k'-' -"Lawr'-'-"=•:.:n:.:n:.:•...:' ::Co:.:=1111:=...:t::ru.::.:e:.:t=i:::ou=-------------'-----------
Amount of Permit: $ -~3,_,7_,.'-'9"'5'-------'-
· White -Treas.
Canary_-Office
Pink -Applicant
.Gold -Duplicate
Permit:
Plan
2.3.00
14. 95
Date: Karch 11, 1993
S, Archuleta
Clerk
,
1I'.i~~;,i rt);L_,~,1;· \',i;z::• ~rr 1~,
I W'. r1K11 " ~ 1993' !H !I JJ.',~---. '·:_~~----~-ii.VJ
(?.;.,r:u::. ! ;:_~·t r,i ...-·.,:-cf.~)f'ir·r
GARFIELD COUNTY
APPLICATION FOR BUILDING PERMIT
please print or type
--·-----------
PERMIT NUMBER Lfk ? ;).._
DATE ._3 -j/ -9 3
TO BE FILLED OUT BY APPLICANT _J_ PLOT PLAN
=--1ADDRESS \i\~ \":> \\>->
1
'cil ....
1
~L> \,__ -u;J;f J;it;;.'f-io2'E: Shm1 easement:s, propert:y line dimensions,
H SUBDit'ISION~~d-:..+"to.v~v:cifu b _ all otl1e.r structures 1 specify north, and street
23 rF'ILiiVG # LOT # \ BLOCK # name. For odd shaped lots, o.r if space is
~ 1TAX SCI-JEDULE # ____ too s1r.all,. provide sepa:rate _plot plan.
LEGAL (SEC/Tr4N/RNG) # OF BUILDINGS NOW ON PARCEL A/un..e,r .. vS
LICEll!SE #
CLASS OF llOPJ(
NEVI ALTERATION ')( ----~,._-
DEMOLISH REPAIR _ ")(.. ___ MOVE
ADDITION
MOBILE HONE (make/P10del)
S .F. OF BUILDING S .F. OF LOT
# OF FLOORS HEIGHT
# OF FllMILY UNITS _____ # OF BEDROOMS _7.. ____ _
INTENDED USE OF' BUILDING
GARAGE: SINGLE DBL CARPORT: SINGLE DBL
FIREPL11CE ['\.,.,Ai;\;.,~ G\~
DOCUMENTS ATTACHED
WATER SUPPLY --~15=&~· c,f,.f~f-~i~'"l~J>---------·
DRIVEWAY PERMIT
SITE PLAN /II re ,
BUILDING PLANS ;:Se_e_ q,B;...L.f..LJ/i.-0·1/>fu.;
S11NT2'ARY SEWER CLEARANCE E'"X c S ti;,_~ __
ON SITE SEWAGE DISPOSAL PERMIT AfA-
~~~------
02'HER DOCUMENTS (specify)
------------------------------
USE OF BUILDINGS NOW ON PARCEL
c,.;,~../.~~ -----
FRONT PROPERTY LINE
STREET NAl1E/ROAD NUMBER
CHECK IF CORNER LOT
DESCRIPTION. OF WOIJK PIJlNNED
Sef>ea./~d.
I hereby acknovJledge that I have read this
ap[Jlica.tion and the above is correct and I
agree to comply with all county ordin.ances
~~~Cl~gulat:ing building const:ruct:ion.
s:rGNATURE
·------------------~----~~-
FOR OFFICE USE ONLY
V,1LUATION
PERMIT FEE
T01'AL FEE
$ 7-J,ko 0 PLAN CHECK FEE $ #. qs-
$37. 'tS-SCHOOL IMPACT FEE$ NA--
DATE PERMIT ISSUED
---~·----
ZONLNG DISTRLCT e (_/D
TYPE OF OCCUPANCY ---~J'C.'-"'-c_...,,3..L--~----
TYPE OF CONSTRUCTION v>~ \
S.F. OF BUILDING#~.e__S.F. OF LOT Nk{>llt>)
M,1x. HEIGHT No ~ ROAD CLASS. --....;
SETBACKS FR011 PROPERTlLINE: FRONT No ch;... J e ~ I
REAR RIGHT LEFT
OFF STREET PARKING SPACES REQUIRED
3
F.cOOD H.~ZARD ---·
CERTIFIED BLDG ELEVATION
SPECIAL CONDITIONS
PROBLEMS f'!ITH PERMIT
----------------------
ADDITIONAL INFORMA~'ION NEEDED
CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR
OR ENGINEER
APPROVED: J' --l 1-
DATE
•• Rick Lawrence Construction Co.
Box 1055 •Carbondale, Colorado 81623 •Phone 963·3143
2/23/93
Scope of remodel work at Sundberg condo, Unit 251, Ranch at Roaring
Fork
Existing kitchen cabinets, bath vanities, carpet., appliances, and
bath fixtures will be removed.
The unit will then have:
all drywall repaired to a new finish
all new paint through out
all new kitchen cabinets and fixtures
all new bath fixtures including new bath tubs
all new carpet
new kitchen and bath floor tile
install a new Mendota wood burning stove
I ··..,r
,
..
I ;/
. ,,
~. ' •, 'I
PERMIT ·~~~~ OWNER/11.{(USti~/JflCf LOCATION J.j='J/3 tjry 8 '2--
CONTRACT R u /r// r .z_. s-/
THE FOLLOWING ITEMS MAY HAVE BEEN OMITTED FROM YOUR PLANS OR MAY NOT COMPLY WITH
THE PROVISIONS OF THE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED ITEMS
BEFORE BEGINNING CONSTRUCTION. ALL REFERENCES ARE 1988 EDITIONS OF THE CODES.
THESE ITEMS ARE REQUIREMENTS FOR R-3 OCCUPANCIES ONLY (ONE AND TWO FAMILY
DWELLINGS) AND ARE NOT ALL INCLUSIVE OF THE CODE REQUIREMENTS, BUT ARE MEANT AS
A GUIDE TO SOME OF THE MOST OFTEN ENCOUNTERED QUESTIONS RELATED TO CODE
REQUIREMENTS. THE APPROVED· PLANS RETURNED TO YOU SHALL BE KEPT AT THE BUILDING
SITE DURING CONSTRU~TION. FOR ANY REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE
CONTACT THE COLORADO ELECTRICAL INSPECTOR.
THERE SHALL BE A PINAL INSPECTION AND APPROVAL OF ALL BUILDINGS AND STRUCTURES
WHEN CO~ETED AND ~l /l,R&C7AN~ AN~ USE -UBC SEC.ti05 (d). 1.,c f ' h el. 1~/{cf~c~~! t'!::"1ou~7ans11 ~nd 'f~a/~~a~i~:~:t~"rJ'Ji~!l~o 1be ~~o /;(l•e ~ '
in 28 days -UBC Chapter 26. Mortar and grout shall be ~n accordance with
UBC Chapter 24 & Table 24-A and 24-B.
2. Masonry units, mortar, and grout shall be Protected during cold weather in
accordance with uBC Sec. 2404 (c). Concrete shall be protected during cold
or hot weathe.:r::,in' accordance with UBC Sec. 2605 (f) a.hd {g) ~
3. Minimum concrete and/or masonry foundation reinforcem.ent requirements are
shown on the attachment. (Note~ these minimums apply only if a foundation
soils investigation is not performed and the soils a~e assumed to have an
expansion index of 20 or less and footing loads less than 2000 lbs/linear
foot -UBC Sec. '2904 (a) and (b) and Sec. 2906. . .
4. Foundation trost .. Protection is 30" from finished grade., 'lo· top of footing -
UBC 2907 (a). . . .
5. Foundations shall extend a min. of 6" above finished grade -UBC 2907 (d).
6. Provide for the control and drainage of surface water away from the building
-UBC 2907 (f).
7. Foundation walls enclosing a basement below grade shall ~be dapip-proofed on
the exteriorlwith approved materials -UBC Sec. ·1101 (d).
B. Foundation plates or sills shall be redwood or pressure .treated wood (UBc·-
2516 (c)), anQ 'shall be bolted to the foundation with not less than 1/2" dia
bolts embedded, at least 7" into concrete or masonry, spaced not more than
6 feet apart·, rilin. ·of 2 bolts per piece and within 12" of each end of piece
-UBC2907 (f).
9. Exterior conC"rete or masonry piers shall extend B" min. above· grade unless
the posts or. Columns which they support are treated or decay resistant wood.
Columns and posts located in basements shall be supported by concrete piers
or metal ped.estals extending 6" min. above earth and 1 11 • Inin. ,above floor
unless treated· o'r decay resistant wood -UBC Sec. 2516 ( c) 4.
10. Manufactureq trusses, and manufactured joists and beams (i.e. TJI/Micro-
Lams, BCI /Versa-Lams, Glu-Lams, etc.), shall be sized itnd installed in
accordance with the manufacturers requirements •.
11. Wood joists or floor beams located closer than 18" or wood girders closer
than 12" to the ground in crawl spaces shall be treated or decay resistant
wood -UBC Sec. 2516 (c) 2.
12. Girders supported by masonry or concrete shall have 1/2" air space at top,
sides, and ends unless treated or decay resistant wood -UBC Sec. 2516 (c)
5. Ends of beams and girders shall have min. 3" of bearing on masonry or
concrete -UBC Sec. 2517 (c).
13. Floor joists under and parallel to bearing partitions shall be doubled UBC
2517 (d) 5.
14. Floor joists require full depth solid blocking and ~must lap a min. of 3"
over bearing s~pports -UBC 2517 (d) 3.
15. Beams, roof rafters, and ceiling and floor joists shall be supported
laterally in accordance with UBC 2506 (h).
16. Columns, posts, beams, and girders shall have positive connections provided
to ensure against both uplift and lateral displacement -UBC Sec. 2516 (m) .
17. Ends of floor joists shall have 1 1/2" min. bearing on wood or metal and no
less than 3 11 on concrete or masonry -UBC Sec. 2517 (c) and (d) 2.
18. Notches on the ends of floor joists -max. 1/4 joist depth. Bored holes not
within 2" of top or bottom of joist and hole diameter no larger than 1/3
depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not
located ~n middle 1/3 span -UBC Sec. 2517 (d) 3.
19. Floor joists and/or roof rafters are insufficient for the span -UBC Table
25-V-J-l and UBC Standards.
20. Roof live load (snow load) shall be 40 psf below 7,000 feet elevation -UBC
Sec. 2305 (d)-dead loads shall be as required in UBC Sec. 2305.
21.
22.
23.
24.
25.
26.
27.
2B.
29.
30.
31.
32.
33.
34.
35.
36.
37.
3B.
39.
40.
41.
42.
43.
44.
' l .~· .:]
I
Floor live load shall be 40 psf -UBC Sec.2304 (a) and Table 23-A-l -dead
loads shall be as required in UBC Sec. 2304.
Basic wind speed shall be 80 mph -UBC Sec. 2311.
Headers over wall openings 4' wide or less shall be doubled 2" framing
lumber on edge. Over 4' wide the header shall be sized for the span -UBC
Sec. 2517 (g) 5.
Bearing walls supporting two floor loads are required to be a min. of 3" x
4"or 2"x 6" studs with a max. spacing of 16" on center-UBC Sec. 2517 (g) 1.
Wood studs may be cut or notched to a depth not exceeding 25% of width in
exterior walls and bearing partitions and not exceeding 40% of width in non-
bea.ring partitions -UBC Sec. 2517 (g) 8. .
Wood studs may have bored holes no greater in diameter than 40% of stud
width, 60% of width of doubled studs (but not more than 2 successive doubled
studs). No holes shall be bored nearer than 5/8'~ to· ectge of stud -UBC Sec.
2517 (g) 9.
Wall bracing required both sides of each corner and every 25 lineal feet -
the braced panel must be a min. of 4 8" in width perpend.i,:cular to studs -UBC
Sec. 2517 (g) 3. ·
Approximate min. insulation values are R-19 walls, R-25 roofs, and R-11
floors over unheated space -see plans for more specific requirementa -
"Colorado Energy Conservation Standards." ·
Foam plastic insulation shall be separated from the · .. building interior,
including attics and crawl spaces, in accordance with UBC Sec. 1712. Other
insulation ·(including duct and plenum insulation and· coverings per UMC
Chapter 10) including facings shall meet the requirement.~ of UBC Sec. 1713.
Masonry and,.stone veneer units (5" max. in thickness) shall have min. size
of No. 22 gauge by 1" galv. metal ties or No. 9 gauge ga.lv. wire ties and
spaced to support not more than 2 sq. ft. of wall area but not more than 24"
on center ~orizontally. When applied over stud constrllction, the studs
shall be m\9,x. of 16" on center. Approved building paper must be applied
over the sheathing or studs -UBC Sec. 3006 (d).
Ceiling height is reqµired to be 7'6 11 in all rooms except kitchens, halls,
bathrooms / and storage areas which may be 7 '0" min. -UBC Sec. 1207 (a) .-----
Min. stairway headroom clearance is 6'8" -U~C Sec. 3306 f:p).
Min. stairway·, width is 36" -UBC Sec. 3306 (b) and min. landing dimension
in the direct.ion of travel must also be 36" -UBC Sec. 3306 ( g).
Stairways ui~;;·. run 9"; max. rise 8"; max. variation in rise and run 3/8" -
UBC Sec. 3306· (c).
Enclosed usaQle space under interior and exterior Stairways shall be
protected on -the en.closed side as required for one-hour .. fire-resistive
construction UBC Sec. 3306 (m). Fire stops shall be provided in
accordance wi.;th UBC Sec. 2516 (f) 2c. .
Stairway handrails: min. height 34"; max. height 3B"; handgrip. portion shall
be not less than l 1/2" nor more than 2 11 in x-section dimension. Min. of
one handrail ~Squired on all stairways with more than three risers. Min.
1 1/2" space required between wall and handrail -QBC Sec. 3306 (j).
Guardrails of· 36" min. height shall be installed at unenclosed floor
openings and open sides of stairways, landings, ramps, decks or porches more
than 30" above g·rade or floor below. Open guardrails shall have a pattern
such that a spheire· 6"" in dia. cannot pass through -UBC Sec. 1711.
Under-floor (crawl space) cross ventilation is required equal to 1 sq. ft.
for each 150 ~tj. ft. bf under-floor area -UBC Sec. 2516 (c) 6.
Under-floor areas shall be provided with a min. 18" by 24" access opening -
UBC Sec. 2516 ( c) 2. 30 11 by 30" min. if mechanical equip. in under-floor
area -UMC Sec. 709.
All sleeping rooms below the fourth story without a door opening to the
exterior shall have at least one operable window that meets the following
requirements; MtNIMUM clear opening: 5.7 sq. ft.
MAXIMUM sill height: 44"
MINIMUM net: clear opening height: 24" (x34 1/4•: = 5.7 sq.ft.)
MINIMUM net clear opening width z 20 11
( x41" = 5. 7 sq. ft.)
This also applies to basement sleeping rooms -UBC Sec. 1204.
Glazing in hazardous locations as defined in UBC Sec. 5406 (glazing in doors
and adjacent to doorways, and glazing in. windows located within 18"
vertically of a walking surface) ehall be safety glazed or protected.
Glass in sloped glazing (more than 15 from the vertical) and skylights
shall meet the requirements of UBC Chapter 34. Skylights and roof and wall
panels of light-transmitting plastics shall meet the requirements of UBC
Chapter 52.
Provide combustion air for fuel burning equipment per UMC Chapter 6.
Pressure relief valves and/or combination pressure/temperature relief valves
shall be provided with a drain line to a floor drain with min. 1" air gap
' ,. .'•~:
~· ' ' '
·.-=
. l
0
46.
@
48.
49.
§>
@
@
53.
54.
55.
56.
59.
60.
i
or extended to the exterior of the building -UPC Sec. 1007.
Domestic dishwashinq machines shall not be directly connected to a drain or
waste disposer without the use of an approved airgap -UPC Sec. 608 (d)".
Fuel burning appliances shall not be located in any room used or· designed
to be used as a sleeping room, bathroom, or closet or any enclosed space
opening into such room or space* UPC Sec. 1309 and UMC Sec. 704 (unless
listed for such use).
Appliances (including space heating and water heating equipment) shall be
accessible for repair and removal in accordance with the UMC.
LPG fueled appliances shall not be installed in a pit, under-floor (crawl)
space, or basement -UMC Sec. 504· (f).
Appliances located in a garage (or in an enclosure opening into a garage)
shall be located out of the normal path of vehicles or protected from
damage. Any portion of the appliance creating a flame, spark or glow shall
be installed a min. of 18" above the garage floor -U!1C Sec. 508.
Each water closet stool shall be located in a clear space not less than 30"
in width and 2·4" in front of stool -UBC Sec. 511 (a).
Toilet rooms' wit:t;iout operable windows shall be equipped with an exhaust
system ducted to ·the exterior -UBC Sec. 1205 (c). ·
Showers and Tub/Shower enclosures shall have a smooth, hard, nonabsorbent
surface to a height of 70" min. above the drain inlet -UBC Sec. 510 (b).
Water-res is tent <jypsum board shall not be used over vapor barriers / in
saunas. or steam rooms, or on ceilings -UBC Sec. 4712 .. '·
Attic access' opening of not less than 22" by 30" is requir.ed -UBC Sec. 3205
(a). 30" by 30" if mechanical equip. in attic space -UMC-Sec. 708.
Enclosed attic and rafter spaces shall have cross ventilation of min. 1/150
of the area o.f the space ventilated. The area may be .. 1/300 if provided
equally at lower and upper portions of the space with-min. 3' vertical
separation of _locations -UBC Sec. 3205 (c).
Garage side of common wall between living space and garage shall be finished
with materials,· approved for one-hour fire-resistive construction, This also
applies to ceil.i.ngs and bearing walls if living space above the garage.
Self closing mln. 1 3/8" solid,, tight fitting door is require·d between house and
r;arar,e lIBC 503 (d) 3. '
Electrically wired, interconnected smoke detectors are required in all
sleeping room· access areas, near the top of stairways in upper levels, and
near the bottom ·of stairways to basements -UBC Sec. 121~ (a).
Wood stoves an~ factory built chimneys, and manufactured .fir~place units and
venting systems shall be installed in accordance with the manufacturers
listing requirements and inspected during installation UMC Chapter 9 and UBC
Chapter 37.
Masonry and concrete fireplaces and barbecues shall meet the requirements
of UBC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any
structural load·other ·than its own weight unless designed as a supporting
member -yac Sec. 3703 (a).
COPIES OF THE ITEM( S) CHECKED BELOW ARE ATTACHED (Copies of any of the items
above or below are available upon request).
Excavations, fills, foundations, and retaining walls -UBC Chapters 23 and
29.
Retaining walls -UBC Sec. 2308 (b) and 2907 (g) 4.
Roof coverings and drainage UBC Chapter 32 {Roof drains sized in
accordance with.UPC Appendix D).
Roof sheathing -UBC Sec. 2516 (i).
Wood combined with (supporting) masonry or concrete -UBC Sec. 2515.
Floor sheathing -·use Sec. 2516 (h).
Wiring in plenums -UMC Chapter 10 and NEC.
Fire and draft stops -UBC Sec. 2516 (f).
Nailing requirements for connecting wood members -UBC Sec. 2516 (j).
Enclosure of elevator, vent, and dwnbwaiter shafts, and clothes and rubbish
chutes -UBC Sec. 1706 •
Exterior wall coverings and exterior weather protection -UBC Sec. 1707 (d)
and 2516 (g).
Interior application of gypsum wallboard and interior and exterior
application of lath and plaster -UBC Chapter 47. Manufactured wall and :•
ceiling covering systems (simulated stucco, etc.) shall be installed in
accordance with manufacturers requirement.a.
Landings and floor level at doors -UBC Sec. 3304 (i).
Cross connection control and back flow prevention -UPC Sec. 1002 and 1003.
Treated Wood Foundation Systems -UBC Standard 29-3.
i
INSPECTION WILL NOT BE '~ADE UNLESS
THIS CARD IS POSTED Od THE JOB
24 HOURS NOTICE REQUIItED FOR IN,"':;'l' CTIONS
~~~~~~~~-'
BUILDING ij:~.RMIT
GARFIELD COUNTY, COLORA~ .
Date Issued3/!//fJzoned Area .... f?t.(./?Permit No.. ~ ~ ~.
AGREEMENT
Use L-J,..JC_iLLLJl,.Jl:,.A._5;.,-J--c~C""""11:;.l_.!_.:_}---'l1~-::oo~-'-~"-)~'.._J;;l!J3'LJL_-::---.
Address or Legal Description /u"=-.Lu..::l _ _f_L'~~'/-,..J~~-1;~..;;'~LJl.lW~:.J.!ii!-,l,.
owncnlo '{ · ~. Su
Setbacks Front Side Hear
This Card Must Be Posted So It Is Plainly Visible From the St~et Until Final Inspection.
INSPECTION RECORD
Zoning
Footing
Foundation
l)lu1nbing~U nderground
Gas Piping
Fraine
Plumbing-Rough
Roof Covering
Electric-Final (hy STATE inspector)
MASTER PJ,UMJ~ER LICENSE If ft7<J~34--
Heating Ventilation
Insulation
Drywall
Electric-Rough f!'I ·7 0) .\
(hy STATE inspector) J-/S'l J" .5L Final
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 945-8212 109 8th Slree1, County Courthouse, Glenwood Springs, Colo.
A~Pf/,~0 I"? NOJfK'<l'ROY TH. IS CARD
Dote • By {) 1 ~ /::J.{),/ktJ I SI(
. IF PLACED OUTSIDE -COVER WITH CLEAR PLASTIC
/
.' ls9ued Wllhoul fee
Building Permit No·. --'---_Ji.~£. _____ .:._____------Zone Dislrict ~lill'-------
si tuated al __ l~J__ll;llibWJU-1t2_.__t_~:r:_b_Q.ridl!le Lot ___ Blk. ___ Addilion -----
for Lhe following purpose Reut<'.'de!J:!gxk __ ~t Unit 251 jS\nla N"ture of U9B)
Contractor._ Rick Le.wren.~ CoE_.~:;-uetJon
: 'l
\
I
J
1
I
._._ .• ~,,,....;_,._,_,., ~,_'..,.,,,..L•··"""'.W.>"-'-'~1"·"-"'~"-;-'.i.'-"'-'.!.......;..•,;,..;,i..,...,_, .. ,".......'...i'l,...,·.J.O'.,;w~~·~~'-""\...,.C..,. J..~~~~:;~·1,.....:..u,( • .i:,:.'.•,",.U.....•-"'·~·-';;~~•'-'--"..U:.;....,.,:.l ___ ,_.,:,.,:_..,,,.,J