HomeMy WebLinkAbout4933--.,::--\"' __ \--·;
GARFIELD COUNTY·
BUILDING, SANITATION and PLANNING DEPARTMENT
109 8th Street Suite 303
Glenwood Springs, Colorado 81601
(303) 945-8212
04933
1293 County Road 117, Glenwood Springs JobAddress _________ _:____: _____ :__ _____ _:___ _ _.:::.. ______________ ~----
Nature of work ___ B!'..'!u=i=l~dc::i:!!n"'-_oP-=e~rc"m~i~t'--------------------------~------
Use of Building __ __llBJie(llptJl.;;au;c:J:eu}'.ll!ol.Jb;z;11..' lwee....JH'1.!0llJm111ee_ ______ c__ ____________________ _
Owner _____ ____oTEa~n~b~e~r2g;__,&~B~l~e~v~i~n~s~,-=In~c~.------------------~---;-----
Cc itractor ----~OWn~~e;.=r'---------------~----------------~----
An.cunt of Permit: $ --'l"'O"'O::..:..• 0=-0-~------
Permit: 100, 00
White -Treas.
Canary-Office
Pink -Applicant
Gold-·Duplicate
S. Archuleta
Clerk
GARFIELD C:OUNTY
Af'PLICATION FOR BUILDING PERHIT
P!llti!IT NUMBER 19 33
DAT!l /lJ-jf-93 lJleuse print or type
, TO BE FILLED OUT JIY APPLICANT
-· -ADDREss l'ZS3 a:..~o l 17; G . .S.
SUBDIVISION----------------~
F' II.ING II 1;0'.l' II BLOCK II -----c----
7'AX SC II EDU r.E I/
LEGAL (SEC/7'1vN/f<NG)
:r: t'>d Nl111E
~ ffi ADDRESS CITY ------
"' NAME ~ l!DDRE_S_S ___________________ _
;,! CITY ~ --------
0 !'//ONE LIO:NSE: /I u
CLASS OF HORK
'/Eli AL1'ERAT.fON llDDI7'ION
-~--
IJEMOLISll REPA Ill MOVE:
!IOBILE l/0-/l_E___ -c:----'f](,.
.'>.F. 01' BU.TLDING fJ.S.l'. 01' L07'
II 01' F'LOORS I /IEIG117' ~1_3~'------
1! OF' FAMILY UNITS fl_ OF BED/WONS 3 ~=--
1N7'ENDED USE OF BUILDING MANAfA?'S Gt11Ag::fEp-S
r;ARAGE: SINGLE DBL CAil PORT: SINGLE DlJL
FIREPLl!CE
IJOCutlliNTS ATTACHED
rv-,1-1-'E_ll_S_UP_P_L_Y_.:.:.:.:.:1 ... A-~'r-a=.,,~~~L-:~:.:.:;:.:.:~.:·.:.:.:.:.:.:.:_-_-_-_
DRIVEl1AY l'ERM I7' -~E)l._..,..,l_S"-..--'-1 _,_l_,_W""""---------
S I7'E l'LAN aJO,,Q?EO
DUIT,DLNG l'LANS eNCl.p?£.J>
SllNLTllRY SErvEll CLEllRllNCE 6@\\01P SV'@.!Nl:sS
ON SITE SElvllGE DISl'OSJIL l'E:RMI'I' ~N-·_1'_. ______ _
OTllE:ll DOCUMEN1'S (specify)
_Cc$[ or ~ ~KlDN $ 2i.'S""t:D'
X:-11-s,o.epadr jl--Cav1/lff2/ /-o?C[Jt.oc r<t~~-r
S-Krri nro
PLOT PLAN
NO'l'E: Shah' easen1ents, property line dimensio1
al.l other structures, specify nortl1, and stre(
n~1111e. For otid shaped Jots, or if space is
too srrtcJl_Z, l'rov_idc se}Jarate plot J'lan.
,II OF BUILDINGS rvorv ON PllRCE[,
USE Of' BUlI.lJINGS NOW ON PllllCEL
---------------------~~--oJ i
FRONT PROPERTY LINE
S1'1ll<:ET Nlll!E/flOllD NUMBER
Cl/ECK If' CORNEil L07'
DESCRIPTION OF rvORK l'LllNNED ~1'L~t1EWI"
o,: H0/!3//,. !-MMC.
I he.reby acknowledge that I 11ave read this
al]Plicatio11 and the al)Qve is correct and I
il.gree to co111pJy l'li th all county ordinances
st te laws regulating building constructir
FOil OFFICE USE ON!,Y ·---~&"'--~--------------
\!llLUllTION ~-------------------
/'EllNIT FEE $ l'LllN Cll/i'CK f'E:E $
T01'JIL f'EE $/CJ().-SCllOOL 1/11'AC1' f'EE $
1Jll1'E l'EllMIT ISSUED ----------------ZONING DISTRICT .,.---,-,-;o,-----------·
TYPE OF OCCUl'llNCY _,_,_,-_,"3'--------~--·
TYl'E OF CONS1'1lUC1'ION ~lf~C/~/~?-~;v,_1_o_v_··_u_~_-/J~·-/1_( ______ _
S. F •. OF' lJUILDING /_,SJ"'J. 2 5 S. F. OF L01'
NAX. llEIGl/7' ( 3 ' ROJID CDJISS, --------5E7' BACKS FROM 1'1WPE!l7'Y J;INE: f'IWN1'
llE"llR RIGl/T LEFT ----
OFF STllEET !'/IRKING SPACES REQUlRED
F' LOOD llllZlllllJ
CEll7'.fFIED DLDG ELEVA7'ION
Sl'ECillI. CONDITIONS
PRODI,E:MS NI1'1/ PEll/U1' -------------
-------------------------llDDI TIONJIL INFOllMllT ION NEEDED
CEln'If' IED Dl' COLORADO REGISTERED LlND SURVEYOI
OR ENGINEER
/
:1~"3~c4.c,~,~,-,t7h_e_ri-,.~•'-<~~,~,. 'l ~ i··-w----:-.r6 ~or;----:
. thence S. 45°23' W. 73.58 1 ; thence N. 27°.
·13' W. 457.84';thence N. 44°19' E. 92.37'"
·;thence· N. 51°59' E. 1S0.87';thence N.
'41°32' E. 144.39';thence N. 36°50' E.
:Iii"~ = '2 s ~~
CARD OF CARDS
;I.~7 __ ._4;}~ _ _'._Jthence N._ 29°40' E. 73~09'1
thence N. 22°09' E. 183.98';·
thence N. 03°26' E, 106.62'
'to the P.O.B.
Total: .---9:"99.Ac."
---
Convenient yel. secluded location,
this RV Park with cabins is graced by
the meandering Three Mlle Creek. •
Heavily '\.VOoded 9+ acres includes 59
campsites, most with water, sewer
and elcctrkal hook-ups, and 12 rental
units. A beautiful utmos/Jhere fur o.
career whkh i']-really a lfestyle,
$975,000. '1t9'0. ..
:•8#8•
,C° >;:!',;.,~,_,,, +> ...
. ::, . ! . f · ·w · rn ,,.-'.
: :._l:)r11t :~~
. "" ... .-.-.-.-.---,---..,.._,
··----. . ..
.,·. ,., ..
~ .. . . . . , ..
H ·~ ·.···• .. 6J'1 <i10J • -=-;: __ :: -.: .... -..
H · ·I c,;;;1;.~ . .,..,----:---·~ ._,c,----;-;·-· -·
i @2lJ<~
:~1~ :~~~ :·"":-::
· 1· !4 ~
-.. -. -. ·ccc..c-. -. :~---.. -.-: ~-·--~-c~;:: '. 2?.,r;,; < • ) •t j . .. .. .. .. . .. .. .. . --·-'] \.i I . . : ....... : : : '.:::: : : : '
--------~-. -
......
-~· rfJ'.
-· ',
1.0 F.RAME
1.1 Main Beams:
'·'-·
SPECIFICI\TIONS fOR
Clll\MPION HOME BUILDEHS CO.
DOUBLE SECTION Ml\NUFI\CTURED HOUSING
J"l\NUI\RY 19 9 0
rr11e fran1e v1ill l)e cons trt1cted in-accord-
ance with third party approved structural
drawings from the following 1naterials:
'l'J1ere a.re th'O n1ain steel I l1ea1ns, sized i11
accordance witl1 the lengtl1 and weight of
the home. Beams shall run the full length
of the home, unless the optional foundation
installation is ordered, which shortens tl1e
frame 8" to 16" on each end to allow for a
block foundation. Beams shall be spaced at
either 80" or 96" o/c. Steel shall meet the
requirements of l\STM/A-36.
1.2 Cross1nembers: Crossmembers shall b" \qeldecl to the bottom
flange of the I-Beam, as required by loads.
Cross1ne1nbers shall be a 1nini1nu1n of 1-1/2 11 x
1-1/2'' x 11 gauge steel angle. Tube out-
riggers (if required) align with cross-
members per approved structural drawings.
1.3 Front
C~1nen1ber:
1.4 llitch:
1.5 Finish:
1.6 Axles:
2.0 FLOOR
2.1 Floor Joists:
2.2 Bottom Board:
HUD
Front crossme1nber shall be tl1e sa1ne 1naterial
as 111ain steel I-bea1n.
llitches will be made of steel I-beam, sized
for the applied load, and welded to the
main beam and front crossmember. Detachable
hitches are avail.able as an opt.ion.
l\ll exposed steel shall be finished to
resist rusting.
Axles shall be as required for transportation
from the manufacturing facility to the site.
The floor will be constructed in accordance
with third party approved structural draw-
ings from the following materials:
Joists sl-iall be norninal 2 11 x 6 11 at 16" o/c.
Joist grade and species sl1all be as
required for roof load, floor load and
frame spacing. Rim joist will be the
same as floor joist.
The bottom side of the floor shall be covered
with a continuous roll bottom board, which
1
2.4 Floor
2.5 Floor Coverinq:
3.0 EXTERIOR WALLS
HUD
3.1 Interior
Finish:
3.2 Wall Heicht:
3.3 Studs:
3.4 Top Plate:
3.5 Bottom Plate:
3.6 Insulation:
3.7 Exterior
Finish:
r'J<::;c_,r sl1ull be insulat.e:~d \·l.i 1-.l: a D.Lar1k:~t of
fiberglass insulation having an uncompressed
R-value of 11. An optional upgrade to R-22
is available at some locations.
Floor joists shall be cove>cccd wi.th 5/3" thick
by full width particleboard or wafer board
subfloor, exceeding the structural require-
ments of 2B-2 decking. Some locations in the
south offer 5/8" T&G plywood subfloor, applied
perpendicular to the joists as an option.
Decking shall be covered with a finish floor
of either vinyl roll goods or wall-to-wall
carpet with pad. Upgrade carpet and pad are
available options.
Exterior walls will be constructed in accord-
ance with third party approved structural
drawings from the following materials:
Walls shall be finished with 5/16'' prefinished
gypswn, glued and fastenc=d to wall studs.
All extc=rior walls will have a minimum height
of 7 '-0 11
• In son1e locations, I' -6·,. v.,;all
height is standard.
E;{terior \·Jalls are const:::::-ucted of 2"~.,:4 11 stc.ds
at 16'' o/c, and shall be from a material
having a minimum Fb rating of GOO PSI.
Ileaders shall be as required for the roof
load. In SOine locations, 2 11 x6 11 r,valls are
available as an option.
Top plate shall be a single l"x4" 'having a
Fb rating of 400 PSI.
Bottom plate shall be a single l"x4" having
a Fb rating of 400 PSI.
Walls shall be insulated with fiberglass
insulation having an R-valuc= of 7. Avail-
able options are R-11 insulation and R-19
insulation with 6'' walls.
Exterior walls will be finished with pre-
finished metal siding or 7/16'' wood-type
siding, applied direct to studs or over
optional Fome-Cor or Dowboard. Other exterior
finishes are available as options in certain
areas ..
2
.. \ . 0 \•/T,LLS, -IN'l'E'RI OR · Interior walls will be constructed in accord-
ance with third party approved structural
drawings from the following materials:
·1.1 Finishes:
~. 2 \</all Eeiqht_:_
4.3 Studs:
;·/all.r, shall be finished with 5/lG" orefinished
9y}Jc;um, glued iU1cl fastened to wC<ll s'L·.:,is.
All walls will have a minimum height of 7'-0''.
In some locations, 7'-6" wall height is
standard.
Studs shall be of a material havin9 a Fb
rating of 600 PSI, or ripped from a material
having a minimum Fb of 550 PSI. Stud size
and spacing will be determined by loading
requirements as specified by the structural
package.
5.0 ROOF The roofs will be constructed in accordance
with third party approved structural drawings
from the following materials:
5.1 Trusses: Roofs shall be constructed using pre-
engineered tested wood trusses, designed
~or the roof land required.
5.2 Ccilina ~inisl1: Ceilings shall be finished with 5/16'' ~r~
finished gypsum ceiling panels, or l/2"
gypsum ceiling panels, fastened to t~e wood
framing with an approved structural ~oarn
adhesive system.
5.3 Insulation:
5.4 Sheathina:
5.5 Roofina:
Roofs shall be insulated with material having
an uncompressed R-value of 11. Optional
additional insulation is available.
Insulation shall be either blown-in mineral
wool or fiberglass batts.
Roofs shall be sheathed with minimwn 5/16"
CDX plywood sheathing or equivalent ~or
shin9led roofs. Sheathing shall be srapled
to roof framin9. Homes with galvanized roofs
do not get CDX plywood sheathing.
Roofs shall be covered with a continuous
galvanized steel roof. Or, if shingled,
either organic self-sealing shingles or
fiberglass shingles shall be applied over a
one-piece approved shingle underlayment.
6.0 DESIGN-LIVE LOAD All structural components shall be designed
to withstand the following loads, as required
by Federal Standards:
llUD 3
.......
6. 2 \•/alls:
G.3 Hoofs:
7.0 HEATING SYSTEM
7.1 Ecuioment:
7 . 2 Ducts:
8.0 PLUMBING SYSTEM
8.1 Drain Lines:
8.2 Water Lines:
8.3 Water Closet:
8. 4 Lava tori,r:
HUD
Floors shall be designed to meet a 40 PSF live
load. In addition, the floor shall support a
200 lb. concentrated load on a l" dia. disc
at any poi11t on the floor.
Exterior walls sl1all withstand a 15 PSF wind
load. Homes designated as hurricane zone
construction shall withstand a 25 PSF wind
load. Interior walls shall withstand a 5 PSF
horizontal load.
Hoofs shall be designed to withstand the
prescribed roof load for the area where the
home is located, usually either 20, 30 or
40 PSF live load.
The home's heating system shall conform to
the applicable Federal Standards in effect
at the time of manufacture.
The furnace shall be sized to heat the home to
70.F when the outdoor temperatu=e reaches the
temperature shown on the compliance
certificate. Stan~~rd equipment is gas f~~ed
forced air, with oil fired forced air, or
elect=ic forced ~ir available as option.
Eu.ch fleer shall Lo.ve a metal l'eat cuct
instnll~d below the floor joists, ~~ith duct
connectors thru the floor for adj~stable
floor registers. Duct will te S 1':{l2'1 and
sized for air conditioning as s~ecified on
the data plate.
The plumbing system shall be designed and
installed in accordance with the applicable
Federal Standards in effect at the time of
manufacture.
All drain piping and fittings shall be
schedule 40 ABS, installed in accordance
with approved illethods.
All water lines shall be polybutyl pipe with
clamp ring insert fittings, installed in
accordance with approved methods.
Water closets shall be floor mounted viterous
china with close coupled tank, complete with
seat and cover.
Lavatories shall be plastic oval mounted in a
countertop with a 4'' centerset faucet and
standard stopper.
4
8 .. 5 .Tubs:·
8.7 Kitchen Sink:
8.8 Water Heater:
Tubs shall bte 27"x5•l" plastic with filucet
ilnd shower rnixing Villve. Garden tubs shall bC>
42 11 -44 1
' :-.: 54 11 plastic witl1 sa1ne t:{pe of
faucet.
Sl1c\.;ers sl1dll 11e 32":-:.3 11n •.v.i t 11 µl.=.i.st._~_.:: t=' !.:1 ~1.1~cl
wall mounted mixing valve and shower head.
Kitchen sink shall be 32"x21" stainless steel
with bac·k ledge for mounting of an 8" center-
set faucet.
Standard water heaters can be 20 or 30 gal.
electric. Optional water heaters are 30 gal.
sealed combustion gas and 30, 40 or 50 gal.
electric.
9.0 DOORS & WINDOWS
9 .1 E;{terior Doors: E~{terior cloors shall be 32 11 :<76'1 met~l or
fiberglass clacl ioan1 filled doors cc:nFlet~
with a keyed entry locksec. Opt~o11a~
combination storm/screen doors or insulated
steel doors are available in many ~reas.
9.2 Interior Doors: Interior doors shall be prefi11ished hollcwcore
doors with a honeycomb fill. Doors shall l1ave
passage locksets, with a privacy lockset in
the bath:::-com.
9. 3 \'iindows: Windows shall be aluminum frame vertical or
hcri=ontal sliding weatherstripped windows,
glazed with SSE glass. Clip-on storms or
self-storing inside storms available. All
bedrooms shall have an egrass window.
10.0 ELECTRICAL
HUD
10.1 Service
Entrance:
10.2 Wirino
Devices:
....... ,.., .. ~·-···· .,.. ...
All homes shall be equipped with main circuit
breaker panelboards with all required branch
breakers installed. All breakers shall have
a 1nini1nuw 10, 0 0 0 amp interupti11g capa.c :!__ t·i.
Service entrance conduit shall terminate
below the floor. The main breaker capacity
shall be sized for the equipment in the heme.
Receptacles and switches shall be
self-contained UL listed devices installed
directly to the wall finish. These devices
allow fer a continuous loop of wire from the
breaker panel to the last receptacle in the
circuit.
5
11.0 CABINETS
11.l Countertops:
11.2 Cabinets:
l:'..O CODES
HUD
,. ......
All 115V/230V wiring shall be done with
copper Romex with ground. Minimum wire size
will be #14 AWG. Wires shall be sized in
accordance with the National Electric Code.
(1984)
Countertops shall be made from 5/8''
particleboard, laminated with high pressure
plastic laminate on tops and edges.
Cabinets shall be constructed using 3/8''
prefinished wood fiberboard approved for use
as cabinet material. Cabi11et doors shall
have self-closing hinges. Drawers shall have
a metal track with nylon guides.
All homes shall be built in accordance with
the design reauirements as found in the
Federal Manufactured Housing Construction &
Safety Standards and third party approved
structural design package. Quality control
~rog~21n shall be followed at t!1e plant level,
and independen~ third party iDspectc=s will
monito= tl1e entire program.
6
I
I
I
I'
I
j
.I
L I
-r---
08GV8 ii .... :i 1~~ \, .... i: Ii~ m li~11i-1 m li~I 1
"' ~ -~~~~~~~~~-.,..~~-1
>-'_J 'z ;o w z 0 l'-l
-·
, ,, '
"THESE , , ES TO 8E~~1 \
\ "10VED WITH SHORTER ~
1
---\ ___,----
\ QV E RHA~I 6-\ -,---; yn_'
~-;~·-.
I 2 • 3 I\ L\..."_:-::--~ _-1 -------:--.-----1
3" ~ r-~-~
j ~ ,---;~;,"--:+-\J'.:ZJ _ _:_J~ --11 I 5
1
/: ["'---'----f I 6 o" 3 -~ I ~
£___1 :r-\
\
'\\
l'r-lf.
5
I ~~1~\
,-----~-3_ay~\ ~ 8J
~r~~\\ ~2~~ \ \;+) '\ ~·
" '!. ----
18
® ~I\ _ ,_--~\\=__i
:1J 2------i----
®
1146'
130' 0 '::~~ i§~· •. ~\\ -~ -11 le__( L~~ -_T2'1:
(i) ~~-!--jf' o·~I~ ,,.
1-1 1131/2'~ _j£Q" . -·--------··---J~'
1 I 5 '1.· r 1 7 3 ';, --, I I~ . -----. --
"" :]3/4"
N 0 TE:
MAX OVERHANG~ 16",
OVERHANG MAY 13E CUT
FLUSH WITH EXTERIOR WALL
OP, ANY 0 IM ENS I 0 N
BETWEEN FLUSH AND 16" i· .. -s
-fi-LfD /1. SNoLU l.DA:D bP'TTD~ VJ k::>
'PuRd-1166t).
"r-
---"
5"
;r:===t:~:.L---. ~
s I
APPROVAL
C) ~~;., ·~~:~:~~~~ 8
< s,Mlll ~TM;O~.,l :::>
'-" 0
O ALIG ~ \9SS o::
""' 23 ""
a.. a..
""'
FOR TEST REPOR. .o.202.A
THIS DRAWING TO BE USED
WITH DRAWING NO. R-___ _
LIVE LOAD=~_:3Cl_ P.SF. ~
DEAD LOAD=~ P.SF. 7'-
TOTAL LOAD= 2 8 I 3 8 P.S.F.
WIND LOAD=~ P.S.F.
SPACING =~"o.c.
CLEAR SPAN= !'54 inches
OVERHANG TO= 3flSTANDARD)
OVERHANG= UP TO 16' inches
FRAME MEMBERS :
SIZE
SPECIES ________ _
GRADE ---------
TRUSS MEMBERS:
11 ' t "
TOP CHORD SIZE I '2 :r: I I c..
BOTTOM CHCRIJ SIZE I 112 ·• l I V 4 '
WEBSIZES 1 1lz1 x l 1tti'
END UPRIGHT SIZE 2 .::.
LUMBER IS RIPPED FROM 2" X 6" NO.:;; S.i:i-.
-875 P.S.I. SGL. M8118ER USE
ALTERNATE MATER!AL:
tlQID,
I) FRAMES (CAT>iEDRAL"""" ~)
MUST BE AS DETAILED.
2) ALL TRUSS PLATE-S ARE 20 GA. GANG NAIL
OR EQUIVALENT. SEE R-24.99
3) ALL PLA.TES SHOWN AF..E 80nt SIDES
UNLESS OntERWlSE NOTED.
4) ALL WMBER TO BE SQUARE CUT UNLESS
OTHERWISE NOTED.
5) SEE R-24.94, R-24.95, R-24.96 FDR
CHAMPION TRUSS AND FR.AME PROO.RAM
AND CROSS REFERENCES.
6e.).l .. i2Ev1<;./0N _f'=.i<."T.t;.!>T _·-·1::=5.~.88 ··---~iz.:.: .. : .. ::.: .. 1·I ---•~U33 ~i-iLi n...:..;v;;: ~;:7,:.;;_:; I : .. ~: ~:: -:.-·_-.-:: :_ -· ••. - : :::..:::: R~;~~ 23 A
~ ADPt:D _1_[,.;,_J_.,('OfO~D •. Dlh€.Hffo('fJ ___ =~.:J=l'f,88 ... [
I· [IB_~ j ~ TITLE; 1 11 1, 4 Q/ PRAWIN(l No ..
MOClfl·:ATIONS
CHAMPION HOME BUILDERS CO.
~ ~
MUNU ~Al H~DRAL TRUSS
~-~
1' APPROVEDBY· 1~ 1 21-a, 2s-r15+1s x /18 ~ R75.23A
'1·
••• -~ '< -... ..... "'' •• ~-~ ... , ,,. •• , .... ~<": ........ _,., ~ ............ ~ ... , .. ..... "· ., ... ,, ..... ,~··· ····~"'"'~'
' ( .
L ----
.: •....... 1..:.··: _;_ .. : ... .::: .... ____ --~--·. ...,,._. ____ .... ___ .:._; _____ • _ _;_, ___ •" _,.i._, _: ~: ... ·--··-:.: --·-•·•'.. ...... ~ •• --LC•;,'••••• •
I l I I l I I I i i
. . "~ ,.,. ···-., ~ ---····· .,., ., ', ... ~··-••r-.,, ...... , ..... ···--··· .. ~ .. -~ .. y
I 11
t
!
. '
. ·--!_, __ _
·-.
. " ............. ~""' ............... . ..... ~, ... ~ ~ ..... ,,.., -~ ., ........ _, ... -....... ~ ..
r-------·----- -----· ----·· -·---------·-----·--------··-------------··-···-------· -~·
,
" ·' ,
'\
c
L
·a:..-
"' w cr:
c
~_J --fj-·
'
' ' 1-B-----B--
' ~ . I
-!p------~
U'.~1'1TH CF 1-!0~1E -------
?~1>-M.UIElii" '.:l(!f'Tl.'o~ i3Y ~THER5. -
\\
Ill ;..1 Cl 8-l>A Ill---, \\ ____CJ___ -a --, __ ----\:\ ___ ·~ . ---
~\\ !'ilQi;.E?EAM 5.UPPCHT OVER
\ \ MARR1 .. GEWALL 'JPEJ'l!NG
\\ FOR LCCATION SEE FLOOR
13..E'._ -"'" "'"~=----\ E~ D ~
r
u
~
r I \\ 7
p___c ----8---"'" "'·' 7 \ \-_f±: -_I --8---~
I ,., ,. : \ \ ii'
14, 4' ~ · I \ i..1...
D~ \. Z
_...,___ I A
l;I -TY<'-::. • -. D
· · -··--0 MAIN c::EAM---ttt-=--=EE}-. --~J----B--D -~\_. -''-8--"' ' -··--· . . ; ' ' : -\ __J
.-+12~ _J. • • A
L a-0 B-0
~e·~
a'...o • .,, i-t:/H i'l'P
TYPICAL CRAWL SPACE FOUi'ICIATION
i'"OR L0CA1"10NS CF Pl£fi$ :;ES: CHAMPION -5 S~f-· UP 1;15TP.U~Tl OHS.
GENERAL 1'~C.TES;
).l..L DES1C:-.N. DETAILS -"-.ND '.·!CrT~'""
A~E 5UbGE5TlVE CNLY AND Ahe.·,
$U6JC:CT i0 THE ..;;JR15Ci(TION
OF 5TATE ANO Oh L·:·C.AL C'.:':DES.
(i1ANGES ~EE i1t-'.l-.DE ACCC'!?.Clf\GLY.
CONTACT YCUR LOCAL EUILDir.;,_;
DE PAR TM ENT FOR FRQ;,7u NE
AND SOIL h.EQIJIREMENT~-
CHAMP10N HOME 6l!1LDERS CG
WARRANTS H~ME ONLY ;:~GM
MAIN 13EAM UF.
FOR. '/EN7iLATION RE':U1Rt:.'.1ENT5
SEE STATE CF.. LOCAL COCE::.
:r _,---MAIN SEAM \:;3·:~~CT WEL~\
;:;:'?i::,::-~ -=tyi i '! '~
SUGGESTIVE . .;.NCHOR ::·ETAIL
TO 6E CHECKED CY OTHERS 1"0
(Qi.FORM ro LA"TEfiAL c:,:;::.1.::. ....
Fk0NT llALL -rT
~•CE WALL r ..... ", :::::~b---WALL
..,.Al N SEA).! --
"· ~;:·.:. .·
' I• ""'-I_. • \, :. _ _J ~ _l\_Jrr;
V-'FJM.Gl'l.ADI:: _ __ ' _, ·-·*"'' ·
, w'N~ • ; '"'7' ' ~\!;', : :~ ~, ,I :;:("''" '" ,
,_ j T' ~"'~"·· 1 ' ·~~·
. ~:'.'.,: 'i"· 1
1!_ ['~
B -B -. --·-
A -A E
' l.IA!N l::EAl.I 11-----,
-.-·.:..:
" 3
"' -· _,
"" <"
; -
"
FUXJR /
FIN GilAQf::
/~'=--"°/''-..... /.-.·· /_,, .--~-... ~
'
1--:-_--,·.·1 /-------
c c D
·•>;: /'i"'
r.
D
s" im•n
~
2 a
~
> < • v
'° •
• 0
~
CHAMPION HOME BUILDERS CO. ··~~·"""---"! ~1-H·!Jf .. !:~ I~ -:-( Fi-::-. -I i~ .. ~£'; I
""-"'-"-""""' ~-~ ii.•~WNI'!' PB•w•...-.-~_IJ... 1~ ~~-·.~cr,;11:._ ~~FAC:. FC:Uf;;OAT!CI~ .!.".'!.."9!!Y!..!!!;.
/ -. ·--•a•...,, v ~----
/' ' i~
i
i
' "· 'I
'
,.
i a1
I I
....1--SIDE '!!'ALL I
r.!All.Rlt.bE
" 11 FLCC:;. ---
"""1ll
111
,f/:-r··.,.;,,.~------------.;,4+~£ ~kw~· s !I i::.:.o<::; Gt:<l.f.IS-
1 'J -
i=<:At.15 1AAI N
8EAM POCKET
c
TO LALLY
4-~-':c.' ::>Ci..TS
"~ • j!I '3 or 4 LALLY COLUMN ., REQUESTED
ALL 8Y OTHERS
I
l' ,, ' " ' ' JU; -' . .-. 'CC ' 'I 1··-· .. ·' ··········I l ·. ~~.:;-..... ~._.__,,·~·,
FLGORf w
'!. ·'.
tCH(fiETE
.,.-
J..-1~·--'-15·_;
SECTION A-A SECT ION B-8
T . lr MAIN 6£Ai.1
~ib
1
" : ! ' L 1-BAC. I ,. I 12.' ;.........:..._ z-A B
=rCRO~SSEAM I
. . I ' . ' . . ' ' lJ),t' ; -1h.--+-l"'·1,'
sxl< ., · 1/4
x I 5. 3. • I j'1 -I . 114 . ~tn I 3 '
\ -· CR0±6EAM A
'' 4-12 60LTS 6Y OTH EAS
I
~I
~1· ·o
~
"' ~
:o1
>I
<D·
'"
,, .
Ei;is ~ H .<, r,.
=-~ ,. -SUGC:ESTl'/E ANCHOR DETAIL
.DETAIL C
SUGGESTIVE ANCHnn OCTA!;_
DETAIL 8 SE':: Sf-!r lJf:;_ Fr.;:_ FLA.N .AND CTHER DETAl'LS
'U' su:LT:Jp BEAM (H:::l~H T 7"0 EE
OETER~INED 6Y C~C~SEEAM A
ANO size. TO E;E CHEC!<EU) IS
FOR H!DEE6r::AMSUPPC'hT.
lT MUST 13E GLUED AND NAILED·
SEE SPECIAL LAYOUT SKE r-CH
FOR LOO:ATION ANO LENGTH.
.tlQll
IF CRO':.SMEMBi:R FALLS OVER
c;:;:ossi=iEAM A -IT MJS.T BE REMO</ED-
MAIN BEAM MUST OEAR ON (R05'.;.8EAM.
6 GENERAL NOTE,
HOLD BACK FOUNDATION
WIDTH UNIT.:o2"!'-~'· , •
WIO"TH FOUHOll-TI0/'1..,2"! "!
LEN;lH UNlT:. ~G'-0
1
'!' 2
LENGTH FOUHOATIOH -\;~'...!!'
I CHAMPIQ~ME 8~ERS CO. l"'~'-"~"~,,.:'~0'~".' __ ,_ >< -~-:11:~ -----------------~ 7Y Pi (AL 2 ~ ~
~-!:Am ~E!.0..!!.!;. fill,~ .!.!!lo!;.. ~
........ ,,;:oe..r: ~t;. .:. ,, ~: ~AS~:.;f~NT Fr-U~JDATiON
~-----~-------------------
•
--~ -----t--·-~ ~
ro
(])
z
~
r-u w
"'
z
0
f---u w
"'
~
i;
i
L---
'
! • u ; . ~
~ -" r-
'.s. w
0
-
~
0
(])
1 ~ ! -"' r-w
0
\ ~ !' i -,-_ ' 0
Ii
I
I
' I
I
: ~I
fil
I I
I
'"' : I I 31
'11 iii
I
I
~ "' u 0. >-r-
~
~-
~ " --1
' ~ r-I-
g
:
, ·1 fi f,
~ glii
;li ~· ~ ~
'
~ < ~ ~ ~ !:! ~ v~--=--==
" _,,.._...._.,,..
., ~
' " l l
r
.. .,::-.. ~ ...
'I ~ ~ 1
i ;1 M
!
!
!
' ' '
. .
~
'''----------------------
--·-----,, I I 'I; l . ,_ ~ <{ u 0. >-~
iii
I
u
u
ii
!
w
I l w
J
~ §
--i
~ z '2 ~ <{ 0 z 0 0 u.. 0: w a:
~
~ ..
~ ~
"
0
~ i
I
I
I
I
I
I
i ;
~' ' l
' (.;") ~
°'' w'
' .'2 0 w U)
~ii :'>j
~i ~:"
i---------
}
~
~
~._J 'l ~ ~-i i I " ;::: -~ ~ -' re I ::J ~ ;;: .._ )-8 ,., .:: JI , ~ ~ ~~
0 ' ·--i " 1·
~ . ~ [1
~r
i ~~ I~ ' ~ " ~-·1 11
·• ~ I il ~ it:
""'"""='
I
I
,.I, ...
. ·J1
j
'·
I
I
El
:0 cc,
c~ 11
f ~Ll~
l _
;
!
l
'
I
;
l
ri
i
j
II
0
·! ~
·; -2
~ "
~ ~
~
1
" 'I ~ . ! ~
IL ______ ~ l
l
-_, ___ -·---·~·
·-~
lbJk,,.,,.=~1-\:tl·-1 1----''-"-="-"~l--J ~ .~
0
··---·~-·----.-
r
L_
' ' J ~ 1 ' I ~ 1 I_, II ii=---------• .
r~ • . ~-.-:;--_ ... -.-: .. -,~IT;:.~.
~
~
•. l
11 "'
I i r1-I r 0 ' i ' ! I ;,
' I i
f. ' I fr! I
I
:
I I
l
~ '
"-~r-;:. ~1'::1~ •• ,
•
' •
'
' ' ..
•
•.
u
Tanberg & Blevins Inc.
1293 C.R. 117
Glenwood Springs, CO. 81601
Attn: Jeff Blevins
GARFIELD COUNTY
BUILDING AND PLANNING
This letter is an attempt to formalize our discussion on March 12, 1994 when I visited 1293 C.R.
117 to update an outstanding building permit for the installation of a mobile home. At that time I
spoke with you while you showed me the installation in question. I noticed only on item missing
which prohibited me from granting a Final Inspection. That item was the absence of steps out the
back door of the unit. At that time I told that I would return on April;( 1994 and you assured
me that the steps would in place. pY ff j//tZJ
Michael E. Watts
71/~/f/j/d?
p~
109 8TH STREET, SUITE 303 945-8212/625-55711285-7972 GLENWOOD SPRINGS, COLORADO 81601
. INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
BUILDING PERMIT
GARFIEL,D COUNTY, COLO,RA9,Pq.3 3 Date lssuedU>f J.l.P3 ... Zm\~d Area ...................................... Perm1t No, ................................... .
1··• AGREEMENT
In consideration of the issuance o[ this per1nit, the applicant hereby agrees l.o con1ply v.·ith
all laws and regulations related to 1he zoning, location; construction and erection of the
proposed structure for "\\'hich .this pcrntit is granted, and further agrees that if the above
said regulations are not fully co1nplied with in the zoning, location, erection and
const~·µ'<p~th. e above described· str. ucture, the pern t 111ay then he revoked by notice
from e oun ~Jluilding In. r a.'.d :fl\ EDI , . BEC 1E NULL AND VOID,
Use . l{(' Vt · iJ'J
,, ~·
Setbacks 'rout Sidl'. Side Hear
This Card Must Be Posted So It Is Plainly Visible From the Street Until Final Inspection.
INSPECTION RECORD
Zoning Roof Coveting
Electric-Final (b S'f1\'IE ins Jector
,/ Footing
,/ Foundation/;-)-'1.3
Plun1bing-U ndergronnd
Gas Piping Heating Ventilation
Frame
Plnmbing-Rongh
Electric-Hough
(by STATE inspector)
Insulation
Drywall
Final
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
TllIS PERMIT IS NOT TRANSFERABLE
Phone 945-8212 I 0 9 8th Street, County Courthouse, Glen\vood Springs, Colo. AP; ~:0 DO NOT DFBTROY THIS CARD
oate ti!· ·· . evt!Z,&d~
IF PLACED OUTSIDE -COVER WITH CI,EAR Pl~ASTIC