Loading...
HomeMy WebLinkAbout5444GARJ<7ELD COUNTY BUILDING, SANITATION and .PLANNING DEl'ARTMENT 109 Slh St.-cct Suite 101 Glenwood Springs, Colorado 81601 (301) 945-8212 No. 5444 JobAdd=is, ____ _::S--'t/'-'3:..L.7 __ c_o_u_n_ty'---R-o_a_d_2...:3_3...:':_S_i_l_t_,:_An_t_l_e_r_s_o_r_c_h_a_r_d...:,_L_o_t_5_1 ___ _ Natureof\Vork ______ =B~u=i=l:.:d:.:1::;.n:.:g::....::P=e=rm~i~t=----------------------~ Use oflluildia,g__ _____ ~M=an:.:u:.:•:.:...:H::o::m:=e:_ ________________________ _ Ow Larry & Pat Tiffany ncr-:------------'--------=--------------------- Conlractor _______ __.::O:.:wn:.::::e::;r:__ ___________________________ _ Amount of Permit $ __ --=.1::0::0.:.• ::.0::.0~----"-­ Set Up Fee: 100.00 Date, ___ Ma_r_c_h'"-'-.1_7_,c.._1_9_9_5 _________ _ S. Archuleta Clerk BUILDING PERMIT APPLICATION GARFIELD COUNTY, COLORADO Aoolica,nt to complete numbered spaces only. PERMIT NO. PARCEUSCHED NO. Joo ADDRESS n R :233 /L/ I I BLOCK ' 1 LEGAL LOT NO. --"' \ l SUBDIVISION \I\ \ \_:-::.S> \. DESCR. ' 2 OWNER) ~ -"'-'\?"""'-~~-' ADDRESS~ .0 .~ 1.,,~ ~.\\;-. PH WK Pl I ... ~::!.-!.o6i l CONTRACTOR I I ADDRESS Pll<:)"l1_ 'l\I. ~LICEt~SE NO 3 4 ARCHITECT OR DESIGNER ADDRESS PH LICENSE NO. ---r-u .. ~ 'IJ{'i('"-" UCENSENO 5 ENGINEER M•AL, / l4 , , , ADDRESS PH . 6 S.F OF BUILDING 161 .. r-.2 "" j<. V'~ S_FOF1.0T \1) ........ ,. .... .,lo.~ HEIGHT NO. OF FLOORS \ . 7 USE OF BUILDING ~,.... --~ 8 ClASS OF WORK ){NEW n ADDITION D Al TERA TION n REPAIR n MOVE n REMOVE ' "~J\-...t\ .. ~~ DESCRIBE WORK: ~, ~ L -'-.\J 9 . -~. ' ' (). 10 GARAGE JM() }"~BIE CARPORT s1rJGLE DOUBLE • ",L .-.. - DRfVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN f1/r~ /-IOl't'l 11 VALUATION Of WORK:$ ADJUSTED VAL.$ PLAN CHECK FEE ---PERMIT FEE /00· , .. SPECIALCONOITIONS ff~~ 110~~ /Jtflt'/1'f,' SCHOOL IMPACT FE~oo. -NO. OF BUILDINGS ON USE OF BUILDINGS NOW ON Gl'tur. r,,,-r? 'M/9.n:tl"tty p," rH. PARCEL PARCEL · TllC P~wl" J' ltlf~"11'rl'1"./ TOTAL FEE OCC. GR. f?·J CONST. TYPE/1/:" H()h NOTICE W/\l'ERSUPPLY Df\TE PERMIT ISSUED SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, HEATING, SPECIAl APPROVAl.5 REQUIRED RECEIVE I) NOT REQUIRED VENTILATING OR AIR C0" ITIONING. THIS PERMIT BECOMf l ANO VOID IF WORK OR CONSTRUCTION AUTHORIZED IS ZONING v j/ NOT COMMENCED •Nn·. DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED ' OR ABANDONED fl. " R!OO OF 180 DAYS AT ANY TIME Af."TER WORK IS COMMENCED, HEALTH DEPT I HEREBY CERTIFY TH~ READ AND EXAMINED THIS APPLICATION ANO KNOW THE SAME TO BE TRUE: JRRECT. All PROVISIONS OF lAWS ANIJ ORDINANCES FIRE DEPT GOVERNING THIS TYPE Ot :JRK Will BE COMPLIED WITH Wl-IETHER SPECIFIED HEREIN O~ THE G~,,NTING OF A PERMIT DOES NOT PRESUME TO GIVE SOIL REPORT AUTHORITY VJC>lATE oR CANCEL THE PROVISIONS OF ANY OlHER sr,\JE OR ~'::&: "j ~"""""" "' '"' """'"~' " . .SETBACKS TR TIO S ~ 9~ "' · ~ \. .. ,(Date\ .... ~ .... ..._ • . Signature of..O...~Contre wtr!zad a~l 11'1·~~arstood norh a·bof) flOODIV\ZARD //N 1L _ _ '~'// ~_,-3 /'7. [; MANUF, F fOME t'f'oing vell'arun~pr~!')~ Lii!' Planning Deparlmenl Approval/dale OTHER -OAGREEMENT PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER; CONTnACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT IN CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREEf; TO COMPLY WITH ALL BUil.DiNG CODES AND LAND USE REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT SHALL BECOME NULL AND VOID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHEr; DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING OPERATION BEING CARRIED ON THEREUNDER WHEN 1N VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS JURISDICTION. THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST. Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND THEAGREEMENT ABOVE !INITIA~~, GARFIELD COUNTY BUILDING AND PLANNING ---------------------------------------------NOTICE------------------------------------------------------- A COPY OF THIS PLAN REVIEW IS ATTACHED TO THE OWNER'S OR CONTRACTOR'S COPY OF THE APPROVED PLANS. THIS PLAN REVIEW IS PROVIDED IN CONJUNCTION WITH OR IN PLACE OF REDLINING THE APPROVED PLAN. IT IS THE RESPONSIBILITY OF THE OWNER AND/OR THE CONTRACTOR TO CLOSELY REVIEW THE PLAN REVIEW AND VERIFY THAT ALL CORRECTIONS NOTED ARE BROUGHT INTO COMPLIANCE WITH CODES ADOPTED BY GARFIELD COUNTY. THE ISSUANCE OR GRANTING OF A PERMIT OR APPROVAL OF PLANS, SPECIFICATIONS AND COMPUTATIONS SHALL NOT BE CONSTRUED TO BE A PERMIT FOR, OR AN APPROVAL OF, ANY VIOLATION OF ANY OF THE PROVISIONS OF ANY CODE, ORDINANCE OR RESOLUTION OF GARFIELD COUNTY. PERMITS PRESUMING TO GIVE AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF CONSTRUCTION CODES OR OTHER ORDINANCES OR RESOLUTIONS OF GARFIELD COUNTY SHALL NOT BE VALID. THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE CHIEF BUILDING OFFICIAL FROM THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA, OR FROM PREVENTING BUILDING OPERATIONS BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF CODES, ORDINANCES OR RESOLUTIONS OF GARFIELD COUNTY. (Authority under the 1988 Uniform Building Code Section 303 (c). titled: Validity of Permit.) THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARFIELD COUNTY FOR ERRORS OMISSIONS OR DISCREPANCIES. THE RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER, BUILDER AND OWNER. COMMENTS AND NOTATIONS ARE INTENDED TO CONSTRUCTIVE AND IN SUPPORT OF THE OWNERS INTEREST. ~~~' Art Hougland, cfuler Building Official PRNOTICE 109 8TH STREET, SUITE 303 • 945 8212/625-5571/285-7972 • GLENWOOD SPRINGS, COLORADO 81601 '""'.-·· .... GARFIELD COUNTY BUILDING AND PLANNING MANUFACTURED HOMES Installation requirements within Garfield Cmmty .... - I. A fuel gas pipeline presstu-e test is required by the installer and the test i~ required lo be witnessed and approved by the Garfield County building inspector. Test must be at a minimum press me of 10 psi and show no appreciable drop within 15 minutes. A gage capable of indicating pressures no higher than 60 psi shall be used in the lest. 2. All stairs serving the unit on the exterior are to comply with the U.B.C. (Uniform Building Code) Section 3306 for rise, nm, handrails and guardrail's. 3. All decks and porches which are more than 30 inches above grade are required to have guardrail's complying with U.B.C. Section 1711 with a mininuun height of 36 inches. Guardrail's shall have intermediate rails or an ornamental pattern such that a sphere 6 inches in diameter cannot pass through. Grade (Adjacent Ground Elevation) is to be measured at points 5 feet horizontally from the level of the walking surface vertically to finished ground, floor or similar surface. 4. If manufactured home is placed on a basement foundatimi the foundation and the basement shall comply with requirements of the U.B.C. including but not limited to: (a) Installation of smoke detectors in the basement and in the manufactured home. U.B.C. Section 1210. (b) Installation of escape or rescue windows. U.B.C. Section 1204. (c) Providing of light, ventilation and sanitation. U.B.C. Section 1205. (cl) Providing of minimmu room dimensions. U.B.C. Section 1207. (e) Protection of insulating materials for flame spread requirements. U.B.C. Sections 1712 & 1713. (f) Forming and placing of concrete for fmmdation and floor slab. U.B.C. Chapter 26. 5. A final inspection of the placement, blocking, tie-downs, skirting, grading and compliance with above items is required and approval given by the building department prior to occupancy of the manufactured home or basement. · (see other side) 109 BTH STREET, SUITE JOJ 945-8212/625-55711205-7972 GLENWOOD SPRINGS, COLOR/\00 81601 .. f------··-···-------------, 01/----------····---------·---------·-··----· -------~ Ar"!! 0 ~~ f'\ •,tn':' 0' C ~ tJ 0 I Tl Pr li'l . LI /)e; ,,,. ~ lf'"fl''J 'l5' 1-. •• ~ C'of"/Pt.11'/l"'('-c... i,,v;TH Ptr?t/ SUDJE:CTTONOTED /?lfYt/11"-fl.Cl/If!' f-l'!Tflf('¥1'f.9' EXCi':vno:--rs .~, JN3PECTIONS I// F'O"-l1"1Ttt11' c;-J\-R_l1JI:.J,,I) (~()iJ1\l''l"Y I I , I : I , I IS i~ I I i I BUILD!~~;. DLl AinJ~JE:,slJj Dam:J_--:n_".gi B~- v11ccT D cooy '1 J~O 1w;;~~:no~ \:/lTHOUT I TH~SE flANS Ctl srri: T1rrHllY /'ltrno;µ~~ eo"'~'~ eo/> y Page__ of ______ _ , ,; ............ --r• ~UILDING PERMIT \ ' 1 GARF~D COUNTY, COLORA~i/¥1' Date Issue~/17/t/Jzoned Area ...................................... Permit No ......................................... . AGREEMENT In consideration of the issuance of this permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location; construction and erection of the proposed structure for which this permit is granted, and further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice e: ' "ldin Insp"., ~!_)IM E I Br.ii~ NULL AND VOID, Address or Legal Descrip!!.h~·o~"'""-;;::;;-;;;--~~~"--~:::!._~~.3~.....-~..J...!.1:...:'-~7~--'---- 0wne.l.ai£~, I f:'Kt.#.A( Contractor (JWIJUC, Setbacks Front Side Rear Side This Card Must Be Posted So It Is Plainly Visible FJ.·om the Street Until Final Inspection. ' •, ·r;""' -.1 .. ,, .. ,"' r., _, ,-e,5_,.,)~NSPECTIO .... ::tECORD Zoning Roof Covering ~·Ii' .. ·: ric-l-·i1L ,, -,;; :"ii'j. Footing { .; r-:;'1.5' • -// . \ < Foundation Plumbing-Underground ' ... ;:_ ' ' -. r-:i f,.'' I _i,-- Gas Piping f~ -1-<ft; f,,J Heating Ventilation Frame Insulation Plumbing-Rough Drywall /., -·7 ~ c/..t:;"'j.-{_" J·~lect rir-l·!. 11 u ~~ :1 !. b~' ~.; r \'! 1'.~ ln··,;·c, Final f.,IC/-0<:-;..(,, ·> ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING - WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND. THIS PERMIT IS NOT TRANSFERABLE Phone 945-8212 109 8th Street, County Courthouse, Glenwood Springs, Colo. ,. ;;·. ·- Certificate Of Occupancy No. 2566 Building Department Garfield County, Colorado No change in the character of occupancy of a building shall be made without a Certificate of Occupancy -(UBC Sec. 502) This certificate is issued pursuant to the requirements of Section 307 of the Uniform Building Code certifying that at the time of issuance, this structure was in compliance with the various codes adopted by the County regulating building construction or use for the following: Install Manu. Home Use Classification---------------------Building Permit No. __ 5_4_4_4 ____ _ Group R_-_3 _________ _ Type of Construction l1fg. Home Zone District ____ _ Owner of Building Larry & Pat Tiffany Address P.O. Box 68. Silt. co Building Address 5939 County Road 233, Silt, co Locality Antlers Orchard, Lot 51 /7 Contractor ----, Address same By , ~ ((. ,(7C((,~ ~..-r Date June 19, 1995 Issuance of a Certificate of Occupancy shall not be construed as an approval of the provision of this code or of other ordinances of the jurisdiction. Certificated presuming to give authority to violate or cancel the provisions of this code or of other ordinances of the jurisdiction shall not be valid. (UBC Sec. 307(a)).