Loading...
HomeMy WebLinkAbout4098/ ' -'ID, T" 1'JI~"•" GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 8th St reel Suite 303 Glenwood Springs, Colorado 81601 (303) 945-8212 J 04098 JobAddress --~0~8~9~0~(b~ur~1t~y,__,Rd,_,,,_, • .___.2Q4~1~-------"N~e~w'--'=ca,,.,,,st~-~J~~~--~------------~ Nature of Work -~Bu=il~· ~d~m~· ~g,_,P'"'enni"', =·,__,t~--------------------------"'---­ Use of Building __ Gar="-ai:"'· ,,_'.:/'"''/c.:S,,_to=ro:.:a:c:g,_,c"'------------------------------ Owner ------'J"'o,,,1_,.·a1'--"J:..:·:.....:.W::'il=S'.J=n'------------------------------- Contractor Gordon/VanHoosc Amount of Permit: $ ~1~4~2~-~7~0<---c-------­ PeYIDit $86.50 While-Treas. Canary -Office Pink-Applicant Gold -Duplicate Plan ~;56. ::10 Date: ~ 0<.."1:01:-.er 17, 1990 Clerk GARFIELD COUNTY APPLICATION FOR BUILDING PERMIT PERMIT NUMBER ~{J 9 ~ DATE JD-17-{) ---ADDRESS LOT # BLOCK # TAX SCHEDULE # LEGAL (SEC/TWN/RNG) ---- NAME"S;i~~~~';f--_.i,-~c!:;'~-'"""=""----;r-7"1c-f::=;-:~ MAIL CITY -NAME ~ ~ ADDRESS CITY ·--.. NAME 0 DDRESS ... u ~ CITY PHONE LICENSE # u Cl.ASS OF WORK NEW 7 ALTERATION ADDITION --------DEM 0 LISH REPAIR MOVE ---.,.-MOBILE IIOME (make/Model) S.F. OF BUILDING S.F. OF LOT -----------# OF FLOORS HEIGHT --.,,,-,,:-----# OF FAMILY UNITS # OF BEDROOMS ----INTENDED USE OF BUILDil)kl ~)--------,..---­ GARAGE: SINGLE_ DBL_J/_~~RPORT: SINGLE l/bBL FIREPLACE DQCUMENTS ATTACHED WATER SUPPLY NA DRIVEWAY PERM~I=T:-'"'~~-------------- SITE. PLAN ..;· BUILDING PLANS -J.?" ~-==-c:::-::---------------S ANITA RY SEWER CLEARANCE ------------0 N SITE SEWAGE DISPOSAL PERMIT ---------0 THE R DOCUMENTS (specify) PLOT PLAN Show easements; property line dimensions, all other structures, specify north, and stree~ name. For odd shapod lot:s, or i.f space is too small, provide separate plot pl~n. # OF BUILDINGS NOW ON PARCEL / USE OF BUILDINGS NOW ON PARCE-L--:{)li-,...,.o~,.-n--rf"--- t: ~_/Alf-( • FRONT PROPERTY LINE STREET NANE/ROAD NUMBER -----------CHECK IF CORNER LOT DESCRIPTION OF WORK PLANNED --------- I hereby acknowledge that I have read this application and the above is correct and I agree to complq wit:h all county ordinances and s egul ti building construction / -~r. t.FOR OFFICE USE VALUATION ,/~ sJ;,,. .... Q.,, PERMIT FEE $;fl{,,,,<;o PLAN CHECK FEE $ !>-(,7,.a TOTAL FEE $ /4 Z.,7V SCHOO[, Il1PACT FEE $ ;t/ A== DATE PERMIT fssuEU- ZONING DISTRICT ----~-L!:.J..--~7;?"--J>---~--- TYPE OF OCCUPANCY --~-~'fv"/1-...,__~~~----- TYPE OF CONSTRUCTION =-A/ S. F. OF BUILDING /I','£<, S .F, OF LOT -::~~­ MAX. HEIGHT .. .:...._ jZQ 1 ROAD CLASS. - / SETBACKS FROM PROPERTY LINE: FRONT41i ... rt •cl REAR RIGHT LEFT -----OFF STREET PARKING SPACES REQUIRED ------- F IFIED BLDG ELEVATION ---------~ SPECIAL CONDITIONS ~------------- PROBLEMS ~TITH PERMIT -----------~ ADDITIONAL INFORMATION NEEDED -------- CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR OR ENGINEER -'----------------- DEPARTMENT DATE -·---#;·---·------··-----"-·-------------·-·-'·-..... '" I ; ~ " ·····+'----. I ,. f !i ' " Ii 1- 1! i-- ' --~- --""'·-·--i-···~.:-..--" --··· -~ ~~ - ::~.-~,--: .. ~..::-.~~::.~~-~:~.,-~--~---~-~--..),. '~ '··---- -., -.__:__l ___ ~-ccce'.'-,0) ... ""--·-'·-":-. . "' ·~---~·-··--·~.~ ... -~-···-· -,_,, ---·· ---- ·.I.) I) t>q -(\ t...l f\l -b -\-.i - -~ -· ~ :J , LJ \ '/\)I fr ... ) I kt \ a I 0, )" <>q i -, ~! '? .·-·-·-- ('> < <.> 1'1-t "" --:::i:: Av.. " (" L_.,.. p 0 /ll \ ' ~---·;--- .,, ' "" . '->-\ / -'t -• 1. t-I I I I I I I :~ .... , . ~-- ·> . ':; ~ ' ' . ' ... 4" ' __.._ ... J I I I I I I I I t--\ __ I .I 1 ...... c 1 " 1\ ' lo! ---- -0 ... - \ -~ I -- I . .'Q - ;--------::-.· . ..I ~ o:· .,.1 ---- )-'I . + . " .... ·-· .; \ .......... ' ./ ......_ "'- .. ---- ._:\>. :;;;\ ·- fl' . I '> ~ 1· \ -· • •• -_., I ----l I I I I ' I I i I ' ' I r I I I I ' I ' I I I ~~ I I t: _ .. ' 'i ---I 1 .. ....--I ' / I ' --·~~ , {._. .,;i . .;. .. ... PERMlT NUMBER ---- CON'l'RACTOR I -.). 'ilA ,.1 I: it) I fl' f .f 'l'llE FOLIDWiti(: I'IBMEy')Hl\VE EITHER BEEN CMITl'ED FOCI'! YCXJR PLANS OR pro NOT CCMPLY WITH THE PROllISIONS OF TllE UNIEDFM BUIIDIN> CDDES. PIEASE OIECK ALL X' D ITEMS BEFORE BEGINNING CXlilSTRUCTION. ALL REFERENCES ARE 1982 UBC UNIBSS OTHERWISE NC11'ED. 1. Shuctural concrete for footing and foundations and load bearing slabs on grade is required to be 3000 PS! within 30 days. 2604 (c) E and Standard 26-1. 2. Reinforcerrent steel for footings: 2#4 rebars continuous. Reinforcerrent steel for foundations: 2#4 rebar at top and bottcm of wall. 3. Frost protection for footings: 30" minimum to the TOP of the footing. 2907 (a). C4°J Foundations shall extend at least 6" above grade. 2907 (a). 0? Provide for the drainage of surface/runoff water away from the building. 2905 (f) (Q.~;:~ Foundation plates on nud sills shall be redw.:xxl or pressure treated wood. 2516 (c) (L..J Foundation plates shall be bolted to the foundation with anchor bolts a rninumum of 1/2" x 7" -6' on center; 1/2" x 15" in unreinforced grouted masonry. 2907 (e) . c_~:' Solid blocking is required between joists at all bearing points. 2517 (d) 3. 9. With joists@ 24" on center: minimum plywood thickness allowed is. 3/4". Table 25-R-l 10. Joists are insufficient for the spans: Minimum x -o.c. Table 25-U-J-l 11. Bean insufficient for loads/spans x MINIMUM size all<YN8d. Tables 25 and 2304 12. A glu-lam or a steel beam is requii:-ed at Tables 25 and 2304 13. 1\11 walls bearing two floor loads are required to be a m:1.n:urrum of 3 x 4 's or 2 x 6 ___ studs with a maximum spacing of 16" on center. 2518 (q) 1,3 <1lJ Shear bracing required: both sides of each corner and -every 25 lineal feet. 2518 (g) 5 15. Brick ties; l" x 22 gauge, spaced a minimum of 16" on center each way. UBC standard 30 , Uf) Ceiling/floor headroom is required to be a min:inu:nn of 7'6" in all roorrs except kitchens, ·· halls, bathrooms and :;itoraqe areas which may be a minimum of 7'0". 1207 (a) rf7')Minimum stai:noell headrOOn rreasured from the oosing of tread is B~'. 3~05, (p) ~ ALL STAIRS: MAXIMUM rise 7-1/2"; MINIMUM nm -10"; MAXIMUM overall variation within a flight of stairs is 3/8". 3306 (c) (RESIDENTIAL EXCEPTION -J!:..ti!'l§l •• f._ ~:· tread) • l~..._, Minimum width of stairways in a single-family dwelling is 30". 3306 (b) "' ., .... _., . 29_1 Handrails: minimum height -30" ; maximum height -34" , hantlgrip portion shall be mt -less than 1-1/4" or uore than 2 inches in cross sectional area. 3306 (j) ~I) Residential guardrails: minimum height -36". Open guardrails and stair railings .... shall have a pattern such that a sphere 6" in diarreter cannot pass through. 1711 EXCEPTION -!SOI.JI.TED COMMERCIAL MAY BE 12" • 22. Underfloor/crawl space ventilation is required. 2516 (c) 6 23. Access to underfloor areas shall be a minimum of 18" x 24". 24. Windows in unfinished baserrents: 4'x 4' with a maximum sill height of 44" or area used for storage only and plans marked "STORAGE: AREA OOI,Y". 1204 (Item 26, below) 25. Windows located within 18" of the floor and 18" or wider are required to be teupered or protected. 5406 (d) 6 & 7 26. EVERY bedroom below the 4th floor without a door opening to the outside shall have at least orte window that meets the following requirements: MAXIMUM sill height: 44 inches -----MINIMUM net clear opening width: 20 inches ----- -----MINIMUM net clear opening height: 24 inches ----,--------.,..,...MINIMUM net clear opening: 5. 7 square feet 1204 27. Provide combustion air for furnace/water heater. tJMC 607 28. Provide floor drain for water heater or pipe P & T relief valve to the outside of the building. UPC 1007 ' 29. Fw:nace and water heater must each be renovable without uoving the other. tJMC 703 30. Each water closet shall have minimum clearances of 24" in front and 30" width (15" center line to nearest sidewall). Section 511 31. Bathrooms without windows shall be equipped with a fan vented to outside air. Section 705 32. Attic access required; minimum opening: 22 x 30 inches. 3205 (a) 33. Fireplace hearth: minimum depth in front of opening is 16", sides 8". 3703 -3704 34. Attic ventilation required; minim.nn l/150th of the vented space. 3205 (c) 35. One hour firewall with a self. closing 1-3/8" solid core door is required between the house and garage. 503 (d) 4 36. A "wired in" electrical snoke detector is required in all bedrcx::rn access areas; for sea:>nd story bedroans, locate the detectors at the toP of the stairway. Any other . alallll trips other alanns. Sane ai:ylies to a basement. 1210 (a) @Headers over doors <ilrl w:ind<:Ms will be on edge. Section 2517 (g) 5 38. 39. 40. 41. 42. 43. 44. 45. I AGREE 'IO CXM'LY WITH THE l\BOVE lW)UIREMENTS DATE: I ( ' ( ( '· ) <£.. I '·' ··-~t''' . _,_....· '__......---------· ~~----- ·· .. . I' .·- J I I /----· • /'. ·\. ', ,,_.;-~ \__ -j