Loading...
HomeMy WebLinkAbout04455GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 108 Eighth Street, Suite 201 Glenwood Springs, Coloradof 81601 Phone (970) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY Permit Assessor's Parcel No. This does not constitute a building or use permit. Owner's Name l l ilii �!�� I ��( ��Q Present Address<%` 1 C Ci -e l Y-- `� - Y'��) le, Phone �1 �� 0401 System Location O Vri CA Mo(.9 S f Legal Description of Assessor's Parcel No /\ \L. Ys Oil \ILO 1 i V I IA 4 0 ix/ .35 �j[� A "-0-07(p SYSTEM DESIGN /240 s Septic Tank Capacity (gallon) Percolat on Rate (minutes/inch) 6 Other Number of Bedrooms (or other) ko- - f'Z Required Absorption Area - See Attached 1309 Ar Pi UC. Special Setback Requirements Date /-c241- G,gi" Inspector /- 6i ryae4. (qr ,�yy])� /,(�/,;)( fs6gga�!��' C44 . a 4 11 ‘,3,-( FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation ) A,C 299 System Installer Septic Tank Capacity c `DI Septic Tank Manufacturer or Trade Name `0'12) Septic Tank Access within 8" of surface 1 0 A1V Absorption Area 21 wtiv.,Ah11 t .A"• ���" 6 Absorption Area Type and/or Manufacturer or Trade Name Adequate compliance with County and State regulations/requirements i (-VP- 1l� Other Date Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE *CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs,alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine —6 months in jail or both). White - APPLICANT Yellow - DEPARTMENT GARFIELD COUNTY SEPTIC PERMIT APPLICATION 108 8°i Street, Suite 401, Glenwood Springs, Co 81601 Phone: 970-945-8212 / Fax: 970-384-3470 / Inspection Line: 970-384-5003 www .garfield-county. corn NLY Permit Fee: r13 ..CO Parcel No: (this information is available at the assessors office 970-945-9134) , / -.L 110. • O " 2 Job Address: (if an address has not been assigned please provide Cr, Hwy or Street Name City) or and 1 •.al description �/ b �� ii�a%�- J . -_(570-1 (Q 3 Lot Size: Lot No: Block No: Subd./ Exem.tion: ^e, 1 I" - 1%1 , 1 Building & Planning Dept: 4 Owner: (property owner) ` � �►A-At". OA cite. s� Mailing AddressAd` r l s `iC is \ k_ , C,W `�S° 9aiPh: l5 -ccfC.0 \ Alt Ph: 319-55`15 5 mtractor: . la4Ko. t Mailin Address �� as °o(,5%,90_, Ph: Alt Ph: — 6 E gineec rcan� Mailing Addresg `:j 11• .L �.yy ( Ph: a `{S � o`Yo!' Alt Ph: 7 PERMIT REQU ST FOR: OO New Installation ( ) Alteration ( ) Repair 8 WASTE TYPE: (1c)Dwelling ( )Transient Use ( )Commercial or industrial )Non- Domestic wastes ( )Other - Describe 9 BUILDING OR SERVICE TYPE: Number of bedrooms Garbage Grinder ( )Yes X)No 10 SOURCE & TYPE OF WATER SUPPLY: K)WELL ( )SPRING ( )STREAM OR CREEK ( )CISTERN If by COMMUNITY WATER, give name of supplier: supplied 11 DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: V VI Was made to connect to the Community System? AJ (i an effort YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITH OUT A SITE PLAN 12 GROUND CONDITIONS: Depth to l51 Ground Water Table Percent Ground Slope 13 TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM (ISDS) PROPOSED: (Septic Tank ( )Aeration Plant ( )Vault ( )Vault Privy ( )Composting Toilet ( )Recycling, Potable Use ( )Recycling, other use ( )Pit Privy ( )Incineration Toilet ( )Chemical Toilet ( )Other- Describe 14 FIN9L DISPOSAL BY: bsorption trench, Bed or Pit ( )Underground Dispersal ( )Above Ground Dispersal ( )Evapotranspiration ( )Sand filter ( )Other- Describe ( )Wastewater pond 15 Will effluent be discharged directly into waters of the state? ( )YES ( )NO 16 PERCOLATION TEST RESULT: (to be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes per inch in hole No.1 Minutes per inch in hole No.3 Minutes per inch in hole No.2 Minutes per inch in hole No. Name, & telephone of RPE who made soil absorption test: address Name, & telephone of RPE responsible for design of the system: address Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional test and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further unders : d that . y falsification or mi - • . - . . ay resu in e tend fof the application or revocation of any permit granted based upon said application p and l`.yafa or mi - • e Aro- . ^OOq _O O � 17 '-0 `' SSIGNATURE DATE NLY Permit Fee: r13 ..CO Perk Fee: (GO . i Total fees: I `l 3. db Building Permit #: l C91 7 Septic Permit #: Issue Date: Building & Planning Dept: APPROVAL DATE HEPWORTH -PAWLAK GEOTECHNICAL May 20, 2008 Blake Timmer 210 Creek Court Rifle, Colorado 81650 Hepworth-Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Fax: 970-945-8454 email hpgeo@hpgeotech.com Job No. 108 053A Subject: Percolation Testing, Proposed Residence, Aggard Lane, Garfield County, Colorado Dear Mr. Timmer: As requested by you, Hepworth - Pawlak Geotechnical, Inc., performed percolation testing at the subject site. The testing was done in addition to our agreement for professional services to you dated February 18, 2008. Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study for foundation design at the subject site and reported our findings March 14, 2008, Job No. 108 053A. A profile pit and three percolation test holes were excavated on May 7, 2008 at the approximate locations shown on Figure 1. The subsoils exposed in the Profile Pit consisted of about one foot of topsoil overlying silty clayey sand to the bottom pit depth of 7 1/2 feet. The results of a gradation analysis performed on a sample of silty clayey sand obtained from the pit are presented on Figure 2. The soil has a USDA soil texture classification of sandy loam. No free water or evidence of seasonal perched water seepage was observed in the pit and the soils were slightly moist to moist. Percolation test holes were hand dug and soaked with water on May 7, 2008. Percolation testing was conducted on May 8, 2008 by a representative of Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table 1. Based on the subsurface conditions encountered and the percolation test results, the tested area should be suitable for an on-site waste disposal system. We understand our Silverthome office will design the septic disposal system. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH - PAWLAK GEOTECHNICAL, INC. Louis E. Eller Reviewed by: Steven L. Pawlak, P.E. LEE/vad attachments Figure 1 Figure 2 —11,.;11 v1:'�` o: Table 1—P-'s,u.' gFi cc: Hepworth—Pawlak Geotec n Test Holes Results ults Attn: Jason Deem Parker 303-841-7119 ® Colorado Springs 719-633-5562 ® Silverthorne 970-468-1989 LEGEND: • PROFILE PIT FOR THIS STUDY. A PERCOLATION TEST HOLE FOR THIS STUDY. O EXPLORATORY BORING FOR PREVIOUS STUDY. MARCH 14, 2008, JOB NO. 108 053A IRRIGATION DITCH ACCESS DRIVE BORING 1 0 PROPOSED RESIDENCE 0 BORING 2 P2 P3 • PROFILE PIT P 1 4 TO AGGARD ROAD NOT TO SCALE 108 053A Ge~'Fc,ech Hepworth—Pawlak Geotechnicol LOCATION OF PERCOLATION TEST HOLES Figure 1 R R TAI 3r HYDROMETER ANALYSIS TIME READINGS 24H,R. 7HR 0 45 MIN. 15 MN. 60MIN19MIN.4 MIN 10 20 30 40 50 60 70 80 90 100 MIN 200 SIEVE ANALYSIS U.S. STANDARD SERIES I CLEAR SQUARE OPENINGS #100 #50 #30 #16 #8 #4 3/8" 3/4" 11/T 3" 5"6" 8" 100 ( 1 90 80 .001 .002 .005 .009 .019 .037 .074 .150 .300 .600 1,18 2.36 4.75 9.5 19,0 37.5 76.2 152 203 12.5 127 CLAY SILT GRAVEL 0 % DIAMETER OF PARTICLES IN MILLIMETERS SAND I V. FINE 1 FINE 1 MEDIUM 1 COARSE 1V, COARSE GRAVEL SMALL 1 MEDIUM 1 LARGE SAND 55 % SILT 29% LIQUID LIMIT % USDA SOIL TYPE: Sandy Loam 108 053A G &t+sch Hepworth—Pawlak GeotechnIcol CLAY 16 % PLASTICITY INDEX % FROM: Pit 1 at 3 to 4 Feet USDA GRADATION TEST RESULTS COBBLES 70 60 50 40 30 20 10 0 NT PA r' Figure 2 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS JOB NO. 108 053A Pa 1 of 2 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P 1 43 10 10 8 3/4 1 1/4 40 8 3/4 8 3/4 8 7 1/4 3/4 7 1/4 6 1/2 3/4 6 1/2 5 3/4 3/4 5 3/4 5 1/4 1/2 5 1/4 5 1/4 5 4 3/4 1/4 4 3/4 4 1/4 1/2 4 1/4 4 1/4 4 3 3/4 1/4 P 2 40 10 Water added 9 1/4 7 3/4 1 1/2 7 3/4 6 3/4 1 6 3/4 6 3/4 6 5 1/4 3/4 5 1/4 4 1/2 3/4 4 1/2 4 1/2 4 3 1/2 1/2 3 1/2 3 1/2 9 1/4 8 1/2 3/4 8 1/2 7 3/4 3/4 7 3/4 7 1/4 1/2 7 1/4 6 3/4 1/2 20 Note: Perco ation test holes were hand dug in the bottom of backhoe pits and soaked on May 7, 2008. Percolation tests were conducted on May 8, 2008. The average percolation rates were based on the last two readings of each test. ( 27 HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE 1 PERCOLATION TEST RESULTS JOB NO. 108 053A Paae 2 of 2 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P 3 41 10 12 11 1 20 11 10 1/4 3/4 10 1/4 9 3/4 1/2 9 3/4 9 1/4 1/2 9 1/4 8 1/2 3/4 8 1/2 8 1/2 8 7 1/2 1/2 7 1/2 7 1/2 7 6 1/2 1/2 6 1/2 6 1/4 1/4 6 1/4 5 3/4 1/2 5 3/4 5 1/4 1/2 Note: Perco ation test holes were hand dug in the bottom of backhoe pits and soaked on May 7, 2008. Percolation tests were conducted on May 8, 2008. The average percolation rates were based on the last two readings of each test.