Loading...
HomeMy WebLinkAbout03798. " "' " GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 109 Bth Street Suite 303 Glenwood Springs, Colorado 81601 Phone (303) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT ,J•-, .. Permit N: Assessor's Parcel No. This does not constitute ; System Location_...,.d-.Q--'-'"""'--"-~"""'U-2:=!...::!o...._:~u21£>..-1<'.1..!.kP'--'-~-'-'!o..L--t-=~~....!;;..ll.J,~.....;~'-~----- ' Legal Description of Assessor's Parcel No. --------'"--'_:_:'-'----=-S __ lf.:__-__ O_D_-_-_:~_:_tf_:_Jj __________ _ ) SYSTEM DESIGN •. -· l • • • ! ______ Septic Tank Capacity (gallon) ______ •Other ______ Percolation Rate (minutes/inch) Number of Bedrooms (or other) ____ _ Required Absorption Area -See Attached Special Setback Requirements: Date _____________ Inspector __________________________ ~~ FINAL SYSTEM INSPECTION AND APPROVAL (as installed) "call for Inspection (24 hours notice) Before Covering Installation System Installer ______________ ,_ _________________________ _ Septic Tank Capacity ______________________________________ _ SeptiC Tank Manufacturer or Trade Name-------------------------------- Septic Tank Access within 8" of surface -------------------------------- Absorption Area ________________________________________ _ Absorption Area Type and/or Manufacturer or Trade Name-------------------------- Adequate compliance with County and State regulations/requirements _____________________ _ Othe'--------------~----------------------------- Date /2-12 -0"3 ct/ Inspector /Jf fJty-t' 3 -11 -"Z~ :2 RETAIN WITH RECEIPT RECORDS AT C()NSTRUCTION SITE •CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Arlicle 10 C.R.S. 1973, Revi"ti 1984. 2. This permit is valid only for connei:tion to structures which have fully complied with County zoning and building requirements. Con· nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual se'Wage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense ($500.00 fine -6 months in jail or both). While· APPLICANT Yellow -DEPARTMENT • • • i t ' j • '" t II l . ' • ' II ' • f, " II } • INDMDUAL SEWAGE DISPOSAL SYSTEM APPLICATION OWNER_~S=h~er~i=c~k,'-"G~eo~r~g~e_-~DG'-"-C~o~n~s~tr~u~c~ti~o-n~,-I~n~c~.-------- ADDRESS OJ so c. R. 1 26. Glenwood Sprfo~s CONTRACTOR Owner -Same as ahqye PERMIT REQUEST FOR (x) NEW INSTALLATION PHONE 945-2719 PHONE ----- ( )ALTERATION ( )REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY: Near what City of Town._N.,.e,..w..__..Ca,..s ... t .... le..__ __________ .Size of Lot 4. 22 Ac. LegalDescriptionorAddress Lot 2 Adair Rippy Exemption, 31850 River Frontage Rd. WASTES TYPE: ( ) DWELLING ( ) TRANSIENT USE (x) COMMERCIALORINDUSTRIAL ( ) NON-DOMESTICWASTES ( ) OTHER-DESCRIBE _______________ _ BUILDING OR SERVICE TYPE: __ c=o=mm=e=r~c=i=al~-~s~t~o~ra=g~e---------------- Number of Bedrooms None 4-Toilets Number of Persons 32 ----- ( ) Garbage Grinder ( ) Automatic Washer ( ) Dishwasher SOURCEANDTYPEOFWATERSUPPLY: (x)WELL ( )SPRING ( )STREAMORCREEK If supplied by Community Water, give name of supplier: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:_~s<-=Mio:l=es"--------- Was an effort made to connect to the Community System? _ __.....,__ ___________ _ A site plan is required to be submitted that indicates the followin& MINIMUM distances: Leach Field to Well: 100 feet 660 FT Septic Tank to Well: 50 feet 660 FT Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet 260 FT Septic System (septic tank & disposal field) to Property Lines: 10 feet 36 FT YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table. _ __,_;P:..:rc:.o_f i;;.;lc:.e_h_o_l_e_t_o_2_3_f e_e_t_-_N_o_w_a_t_er _________ _ Percent Ground Slope _____ ~1L&...l"'--'~2"'%.___ _________________ _ TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: (x) SEPTIC TANK ( ) AERATION PLANT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) CHEMICAL TOILET( ) OTHER-DESCRIBE FINAL DISPOSAL BY: ( x) ABSORPTION TRENCH, BED OR PIT ( ) UNDERGROUND DISPERSAL ( ) ABOVE GROUND DISPERSAL ( ) VAULT ( ) RECYCLING, POTABLE USE ( ) RECYCLING, OTHER USE ( ) EV APOTRANSPIRATION ( ) SAND FILTER ( ) WASTEWATER POND ( ) OTHER-DESCRIBE·------------------------ WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? No ---- PERCOLATION TEST RES UL TS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes -20Qt+ per inch in hole No. 1 Minutes -""4.._o ___ _,per inch in hole No. 3 Minutes 6o+ per inch in hole No. 2 Minutes er inch in hole No. Name, address and telephone ofRPE who made soil absorption tests: T. Carter Page, P.E. 35161 -Gamba & Associates. Inc. 113 9th Street, Suite 214 Glenwood Springs, co 945-2550 Name, address and telephone ofRPE responsible for design of the system: Same as above Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application · legal action for perjury as provided by law. Date '6/zola3 --~-~==~•-""'"------- TE MAP TO YOUR PROPERTY!! GAMBA a ASSOCIATES CONSULTING ENGINllERS 6 LAND SURVEYORS WWW.0. .. !0•••11•111••11111<1 CON PHONE: 970/945-2550 FAX: 970/945-141 0 t 13 NINTH STREET, SUlTE 214 P.O. Box , 458 GLENWOOD SPRINGS, COLORADO 81602-1458 Friday, December 05, 2003 Andy Schwaller Chief Building Official Garfield County Building and Planning 109 8th Street, Suite 303 Glenwood Springs, Colorado 81601 Re: As-Built Drawings for the Sherick Individual Sewage Disposal System (ISDS) for the Commercial Building "E" located at 38150 River Frontage Road, New Castle, Colorado 81647. Dear Andy: Attached please find a two-sheet set of As-Built plans for this system. The system was installed in substantial compliance with the design plans. Final locations and details shown on these plans reflect what was constructed. I do not know the permit number for this system, but it should have been submitted sometime in April, I believe. The drywell was installed and inspected in April and May of this year, and the septic tank was installed later, and inspected in July. If possible, I would like to get a copy of the final permit, for my files. If you have any questions, please do not hesitate to call. Sincerely, Cc: George Sherick, owner File: 03384 H:\03384\As-Builb\AJ.-Builts 11.muaal lo GARCO.doc ----·------- Sherick ISDS -Final As-Built Transmittal -Building "E" Friday, December 05, 2003 Page 1of1 2 <IPPY EXEMPTION 1995 ON No. 4 78884 STRUCTION <IVER FRONTAGE ROAD STLE, CO. 81647 :RES± LEGEND: EXISTING CHAIN-LINK FENCE - ALSO PROPERTY LINE EXISTING DITCH EXISllNG CUL VERT EX!STlNG WATER MAIN EXISTING WATER VALVE EXISTING WATER SERVICE EXISTlNG YARD H't'ORANT EXISTING WATER SHUT OFF EXISTING SHALLOW UTILITIES EXISTING UTILITY VAULT PROPERTY CORNERS EASEMENT LINES PERGOLA TION TEST HOLES PROFlLE HOLE " , , --a --a --a --a --•--a --.. l><I ---------~ * --a --a --a --a --a --a -- c;;:J • --------------------------------- ~ - ~--v--~v~\ ) ~ ' EICISTING ltOCK STORMJE MIO ~,/~j'--~~~ ' -' ' : ~ : ~ ! I ! !i r ~ : i : . ' ' ' ' ' ' ' ' ' ' ' ~ ! --j 10.00' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ·---------------------------------------------------------------------------------------------------------------------------------------------------------------------J 'TI0N EASDIENT -SIOE ""° RE,t,R LOT LINES N00"43'i3"W flON >84 \GE ROAD 647 °)I ~'7)"' 569.66' Sherick ISDS Site layout I SCALE, ,. =II' 11 DATE, -"·-11 DRAl'»I gy, .. I I SHEET, "" II P'OJECT, -11 CHI(!) gy, .w I 1 "'1t~1!r\"r"; ..... l9 ... 111lil1A{Jl,,f..rll111>• d r, • ¥ ~ .tf. George Sherick DG ronstruction, Inc. 38150 Rlve:r Frontaqe !<bad New Castle, Colorado 81 G4 7 ~70) ~S-27/S. GAMBA Be ASSOCIATES, INC. CONSULTING IENGINKIERS 6 LAND SURYKYORS SHEET NO. 1 ;,, f" ~ CT 3 IR RIPPY EXEMPTION E 1, 1995 EPTION No. 478884 :M CONCRETE 00 RIVER FRONTAGE ROAD I CASTLE, CO. 81647 3 ACRES± 3'23"E 636.66' ' 10-FOCIT UllUTY, ORAINME. NIO IRRIGATION EASDilOff -SID( AHO R£Ni LOT LM£S -~ ~ o-cr .r ~ ~ i.ii n-n-'1"-n-rT--.,,rr -~ .U ~ ~~ 0.~n-£T-tr-cr 4•--n--0--0--n--n--n--n--n--o~ )().---------------------------------------------------------------------------------------------------------------------------------------------------------------1 HNG ' -1 : '' '1° h : ' --' EXISTING ""'mATOR BED I 4-FOOT DIA. ' "'"" -""'""-' MANHOLE SECTION S£E DETAILS. SHEET 2 00' j \_ AS-BUil T DRY'NELL 20'w X 45'1 X 19'd SEE DETAILS, SHEET 2 PAAl<ING AREA. ------Po\lt!QNG Mk.A i : 'r s 0 I iri ~ g ~ ~ ~ 0 _.,, ~i'i • en ~~ ~ ffi:z ffi g ____ ;!: &----- ;; & --r--!!l !'i __ _J__ - r,--;--' C{ IJ-- CCJ 7 ---C{ \ \ \ . \ \ \ . ' ' ' ' ' ' ' ' ' ' ' I \ •• 1---32.5'± __, ' r-.""'""''"""'"""""""""""-...'"'"""""""..,.-..,.-..,.-~,,-~~~'"""""'""''""''"""~~""""""'"''"""""""..,.-..,.-..,.-,,-~~<"""r-<'"""''"' \ \ I • I \ • I \ \ . \ \ \ . \ \ \ . I \ •• \ \ \ . \ \ \ . \ \ I • \ \ •• ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' \----19.40' --F' \ ' \ ' > > '\ '\ ' ). ). ), > ). ). ). '\ \ '\ '\ '\ '\ ). ), '\ \ '\ ), ' ). ). ' ' > '\ ). ' ' ' ' '> ' '\ '\ '\I ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' \ \ \ . L---T"-------------------------------------------------------------------------------------------------------· 10.00' 10-rOOT UTILITY, DRAI~ nnl/OS AWUIUS RfV NO. I DATE RfVISION TRACT 1 ADAIR RIPPY JUNE 1, 199 RECEPTION ~ DRT2 CONST 38100 RIVER NEW CASTLE 4.23 ACRES: " l CLEAN-OUT WITH r REMOVABLE CAP ~~~«<-?~ -Tw~ >07>;/);Y/, v;"-: >~ 3.50' >~ I (min.) ~ I I \'" '" """ '~ MINIMUM SLOPE = 23 4" PVC - 2-WAY CLEANOUT TEE 6' (min.) = DRAWING SHOWS INFLUENT PIPE FROM BUILDING ENTERING AT END OF TANK, ACTUAL CONNECTION OF INLET IS ON SIDE OF TANK (SEE PLAN VlEW) ' 24~ CONCRETE COVER / ~ 0o/' -------)~ , ~ v STANDARD 20" METER PIT SECTION ~ -13" min. R l I 1 ,.. (0.4)07 (0.4)02 DI l;;-:-J 02 L~ 4" PVC 90' BEND~ CROSS SECTION OF 1,500 GAL. SEPTIC TANK N TS. ~ BACKFILL AROUND THE DRYWELL, ABOVE THE MIRAFl FILTER FABRIC AND THE WASHED GRAVEL LAYER \S TO BE ACCOMPLISHED WITH NATIVE SOILS, LIGHTLY COMPACTtO, EXCEPT FOR THE TOP TWO FEET OF SOIL 'NHICH. SHALL BE COMPACTED TO 95% OF STANDARD PROCTOR. 4~ SDR35 PVC PIPE FROM SEPTIC TANK,MINIMUM SLOPE :. 2% 48" OfA. SOLID MANHOLE SECTIONS ---------I 12' HIGH (t,W.) IRAFI 500X FABRIC (typ.) 45' tONE SECTION • 24n CAST IRON MANHOLE FRAME AND COVER - GROUTED TO CONE 6. ROCK -RIP-RAP 48" DIA. PERFORATED MANHOLE SECTION -3' HIGH 1~-in. WASHED GRAVEL 18" AOS-N12 (PERFORATED -see detail) CROSS SECTION OF DRYWElLS LOOKING SOUTH GROUND SURFACE O' .................... " " TAN-COLORED : : ~I~~ "v.1.Tlj F~AY: : : : •• NN 0 RATIONS IN ~1 /2~ DIA PERF012 PIPE l 8-inch ADS·~~OCK POSITIONS AT 4 & 8 0 Q 18" AQS-N12 CROSS $ECTI ... ~.£ CALCULATIONS FOR LEACH FIELD SIZE PROPOSED NORTHEAST COMMERCIAL BUILDING IS TO HAVE 9,600 sq.ft OF SPACE, WITH A TOTAL OF FOUR BATHROOMS. ASSUMING 8 PERSONS PER BATHROOM, AND APPLYING 25 GALLONS PER PERSON PER DAY FOR EACH BATHROOM (SLIGHTLY HIGHER THAN THE 20 GALLONS PER PERSON PER DAY FOR A FACTORY). THEREFORE: THE QFS!GN AVERAGE DAILY FLOW: 8 per./bothroom x 4 bathrooms x 25 gol./person/day = 800 gallons/day. AND: THE DESIGN MAXIMUM DAILY FLOW: 1503 OF THE AVERAGE DAILY FLOW: MAXIMUM DESIGN DAI! Y FLOW: 800 gol./doy x 1.50 = 1,200 goL/day PERCOLATION TESTS WERE PERFORMED BY GAMBA & ASSOCIATES AT VARIOUS DEPTHS IN THE IMMEDIATE AREA OF THE PROPOSED DRYWELL IQLJ 1 2 3 DEPTH BELOW GROUND 6-FEET 14-FEET 17-FEET SOIL TYPE TAN-SILT w/ CLAY TAN-SILT w/ CLAY & SAND BROWN-SILT w/ CLAY PERCO! ATION RATE >200 min./in. >60 min./in 40 min./in. THE UNIFORM TAN COLORED SILT WITH CLAY EXTENDS FROM THE SURFACE TO A DEPTH OF APPROXIMATELY 16-FEET. THE BROWN SILT WlTH CLAY EXTENDS FROM APPROXIMATELY 16-FEET TO 23-FEET BELOW THE SURFACE. AT APPROXIMATELY 23-FEET BELOW THE SURFACE RIVER ROCK WAS ENCOUNTERED NEITHER SOLID BEDROCK NOR WATER WAS ENCOUNTERED TO A DEPTH OF 23-FEET BELOW THE SURF ACE IN THE PROFILE HOLE. THE DESIGN FOR THE DRYWELL WlLL HAVE ALL OF THE NATIVE SOILS EXCAVATED TO THE DEPTH OF THE RIVER ROCK, AND A FOUR-FOOT THICK LAYER OF CLASS 6 AGGREGATE BASE COURSE PLACED OVER THE ENTIRE BOTTOM LAYER OF THE ABSORPTION AREA. THE CLASS 6 SPECIFICATION IS; SIEVE SIZE 3/4 #4 #8 #200 % PASSING 100 30-65 25-55 3-12 MEASURED PERCULATION RATE FOR THE CLASS 6 MATERIAL BEING USED IS 16 mln./in. THE ABSORPTION FIELD STARTS ON TOP OF THE FOUR-FOOT SELECT FILL (19-FOOT) LAYER, AND WILL EXTEND UP TO 16-FOOT BELOW THE SURFACE. THE MAJORITY OF THE FLOW WlLL BE THROUGH THE CLASS 6 LAYER IN THE BOTTOM OF THE FIELD, TO THE RIVER GRAVELS. THE REMAINDER OF THE FLOW WlLL PASS THROUGH THE SIDEWALL AREA IN THE BROWN SILT/CLAY LAYER. THE DRYWELL WILL BE SURROUNDED BY 1j-INCH WASHED ROCK. THE WASHED ROCK LAYER WILL BE SEPARATED FROM THE NATIVE SOILS BY A LAYER OF MIRAFI 500X FILTER FABRIC. THE REQUIRED AREA FOR THE ABSORVilON FIELD IS CALCULATED USING AN AVERAGE OF THE TWO SOILS THROUGH WHICH THE EFFLUENT WlLL PASS: AVERAGE PERCOLATION RATE FOR DESIGN: 16 min.fin + 40 min./jn. = 28 min.fin 2 MINIMUM AREA FOR THE DRYWELL rs CALCULATED PER GARFIELD COUNTY HEALTH DEPARTMENT DESIGN CRITERIA, USING .. ' ' .... -.... "'>1 nnc_r\1.... Q = MAX. DAILY SEWAGE FLOW = 1,200 gpd t = AVERAGE PERCOLATION RATE = 28 min./in. THEREFOREo A= (120plxf28 = 1,269.96 s.f. CONSERVATIVELY, 1,270 sq.ft WlLL BE USED AS THE MINIMUM ABSORPTION AREA. THE AREA OF A DRYWELL IS COMPUTED FROM THE AREA OF THE BOTTOM OF THE DRYWELL, PLUS THE AREA OF THE SIDEWALL BELOW THE 16-F LEVEL. THE DIMENSIONS OF THE ORYWELL AREo BOTTOM WIDTH = 20-FEET. BOTTOM LENGTH = 45-FEET. PERMEABLE DEPTH =' 3-FEET. ;;T-------- ,. / 4~ PVC SEWER PIPE MINIMUM SLOPE = 23 TO DRYWELL ~" PVC ""JI:E ~ KD APPO ( BY ' TO DRYWELL Sherick ISDS Details BOTTOM AREA· 20' x 45' = 900 sq ft. SIDEWALL AREAo [2( 45') + 2(20')]3' = 390 sq ft. TOTAL AVAILABE AREA = 1,290 sq. ft HORIZONTAL DISTANCES BETWEEN SEPTIC SYSTEM COMPONENTS. ABSORPTION BED TO ANY DITCHES OR WATER COURSESo ABSORPTION BED TO POTABLE WATER SUPPLY OR SUPPLY UNEo ABSORPTION BED TO PROPERTY UNESo ABSORPTION BED TO SEPTIC TANKo ABSORPTION BED TO SPRING OR WELLo MINIMUM DESIGN 66 ft. 260 ft. 41 ft.•• 30 ft •• 10 ft. 36 ft. 6 ft. 6 ft. 116 ft. 660 ft. " NOTEo THE DESIGN HORIZONTAL DISTANCE FROM THE EDGE OF THE DRYWELL TO THE CLOSEST WATER SERV1CE IS 30-FEET. THE EXTREME DEPTH (16-FEET TO 19-FEET BELOW SURFACE), OF THE ABSORPTION AREA, ANO THE UNDISTURBED AND VIRTUALLY IMPERMEABLE, SOILS (>200 min./1n.) BETWEEN THE WATER SERVICE LINE AND THE ABSORPTION AREA, AND THE SEAMLESS NATURE OF THE WATERLINE ITSELF (1j ,n, PURECORE HOPE), WlLL EFFECTI' COMBINE TO PREVENT CONTAMINATION OF THE WATER OR INNUNOATION OF THE ABSORPTION AREA. ALL COMPONENTS OF THE SEPTIC SYSTEM SHALL BE INSTALLED ACCORDING TO GARFIELD COUNTY AND COLORADO DEPARTMENT OF HEALTH CODES, AND ACCORDING TO MANUFACTURERS SPECIFICATIONS. DG George Sherick Construction, Inc. 381 50 River Frontage Rbad New Castle, Colorado 8164 7 (970) 94!5·2719 SHEET NO. I ™' AS IOllD 11 DATE, -"· .... ==1 @RAWI< BY' .. I GAMBA & ASSOCIATES, INC. 2 I SHEET, hl2 11 PROJECT, .... 11 CHKD BY. ... I I DRAWING: ................ ..... I DIRECTORY:..,...' t\ GAMBA A AaaOCIATKa CONSULTING l!NGINIEICltS a LAND SURVEYORS 970/94S-USO WWW.GAMBAENGINl!l!RING.COM ••:a NINTN9T.,aTLat• 11'.0. 90X ..... GLIENWOOD ........... co••-