GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT
108 Eighth Street, Suite 201
Glenwood Springs, Coloradof 81601
Phone (970) 945-8212
INDIVIDUAL SEWAGE DISPOSAL PERMIT
PROPERTY
Permit
4163
Assessor's Parcel No.
This does not constitute
a building or use permit.
,, [ 95''t— Sri
Owner's Name d -v 11f -Y\ i s Present Address r r I 1 r� Phone
y
System Location t�it,p t•-, �'--
r
3
Legal Description of Assessor's Parcel No 0+ / J 5.x .1 l
e`6
SYSTEM DESIGN
Septic Tank Capacity (gallon) Other
Percolation Rate (minutes/inch) Number of Bedrooms (or other)
Required Absorption Area - See Attached
Special Setback Requirements:
Date Inspector
FINAL SYSTEM INSPECTION AND APPROVAL (as installed)
Call for Inspection (24 hours notice) Before Covering Installation
System Installer
Septic Tank Capacity
Septic Tank Manufacturer or Trade Name", 11L
Septic Tank Access within 8" of surface
Absorption Area
Absorption Area Type and/or Manufacturer or Trade Name
Came-ik, b 7 07
Adequate compliance with County and State regulations/requirements
Other
Date 2-7-07 Inspector KJ p ottos-4')
RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE
*CONDITIONS:
1. All installation must comply with ail requirements of the Colorado State Board of Health individual Sewage Disposal Systems Chapter
25, Article 10 C.R.S. 1973, Revised 1984.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Con-
nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a
requirement of the permit and cause for both legal action and revocation of the permit.
3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material
variation from the terms or specifications contained in the application of permit commits a Class 1, Petty Offense ($500.00 fine --- 6
months in jail or both).
While - APPLICANT Yellow - DEPARTMENT
INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION
OWNER ET r ,` c ) C 447 C f 6,E., q)51—g161- Zit / t3
ADDRESS 3 701 5W / r' S'4 J r,/i i44- re' 3 302 PHONE yy1- Z t(5
CONTRACTOR Z 4144 r / lc ✓�' �'
ADDRESS t c7 J D .\--75-1/ cAv.i.,,tii4 60 Sl(0ZS. PHONE c ?() '63—f 359
PERMIT REQUEST FOR (4 NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable
building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4).
LOCATION OF PROPOSED FACILITY:
Near what City of Town 62/ill w0o4 Sfl ci i5 S Size of Lot 3 7. CA-tft s
Legal Description or Address j 7 H, c4 ,/ 3 ' e'i 1,0/- . 6 (i s (c. C 6 ca
WASTES TYPE: (X) DWELLING ( ) TRANSIENT USE
( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES
( ) OTHER - DESCRIBE
BUILDING OR SERVICE TYPE:
Number of Bedrooms
Number of Persons -t
( ) Garbage Grinder (x) Automatic Washer (4 Dishwasher
SOURCE AND TYPE OF WATER SUPPLY: (y) WELL ( ) SPRING ( ) STREAM OR CREEK
If supplied by Community Water, give name of supplier:
DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM:
Was an effort made to connect to the Community System?
A site plan is required to be submitted that indicates the following MINIMUM distances:
Leach Field to Well: 100 feet
Septic Tank to Well: 50 feet
Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet
Septic System (septic tank & disposal field) to Property Lines: 10 feet
YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT
A SITE PLAN.
GROUND CONDITIONS:
Depth to first Ground Water Table
Percent Ground Slope
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
2
g<)
SEPTIC TANK ( ) AERATION PLANT ( ) VAULT
VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE
PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE
CHEMICAL TOILET( ) OTHER -DESCRIBE
FINAL DISPOSAL BY:
ABSORPTION TRENCH, BED OR PIT ( ) EVAPOTRANSPIRATION
UNDERGROUND DISPERSAL ( ) SAND FILTER
ABOVE GROUND DISPERSAL ( ) WASTEWATER POND
OTHER -DESCRIBE
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE
STATE? PERCOLATION TEST RESULTS: (To be completed by
Registered Professional Engineer, if the Engineer does the Percolation Test)
Minutes per inch in hole No. 1 Minutes per inch in hole NO. 3
Minutes per inch in hole No. 2 Minutes per inch in hole NO.
Name, address and telephone of RPE who made soil absorption tests: /il) C•r7 -Ice/
f12 O Ccr 4 gel ISS( C--(011(..44 poci 5,�, Co / o1 el - .5 79g '
Na/me,( �a�ddrress and telephone �off RPE responsible for �design of tthe system: Sctime1,�s,9,:/r�/v,4/r%ycf�,.-
Ii (V U 1I51 5-0, Z C) C:Lptcu igv €/' 6, Y(60( J -7()"'94S_ 100 '7 C.. IAy V-6 fJt' `e,,
Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and
additional tests and reports as may be required by the local health department to be made and furnished by the applicant
or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is
subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made,
information and reports submitted herewith and required to be submitted by the applicant are or will be represented to
be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of
health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any
falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based
upon said application and in legal action for perjury as provided by law.
Signed
Date R(43/(7c
PLEASE DRAW AN ACCURATE MAP TO YOUR PROPERTY!!
3
HEPWORTH - PAWLAK GEOTECHNICAL
September 14, 2005
Eric Schmidt
3401 SW 195th Avenue
Miramar, Florida 33029
f-Iepworth-Pawlak Geotechnical, Inc.
5020 County Road 154
Glenwood Springs, Colorado 81601
Phone: 970-945-7988
Fax: 970-945-8454
email: hpgeo@hpgeotech.com
Job No.105 360
Subject: Subsoil Study for Foundation Design and Percolation Test, Proposed
Residence, Lot 16, High Aspen Ranch, Garfield County, Colorado.
Dear Mr. Schmidt:
As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and
percolation test for foundation and septic disposal designs at the subject site. The study
was conducted in accordance with our agreement for geotechnical engineering services to
you dated May 2, 2005. The data obtained and our recommendations based on the
proposed construction and subsurface conditions encountered are presented in this report.
Hepworth-Pawlak Geotechnical, Inc. previously conducted a preliminary geologic and
geotechnical study for development of the subdivision and presented our findings in a
report dated March 4, 1996, Job No. 195 531.
Proposed Construction: The proposed residence will be a residence will be a two story
log structure over a walkout basement level located on the site as shown on Figure 1. The
attached garage and basement floors will be slab -on -grade. Cut depths are expected to
range between about 3 to 10 feet. Foundation loadings for this type of construction are
assumed to be relatively light and typical of the proposed type of construction. The septic
disposal system is proposed to be located downhill to the south of the residence.
If building conditions or foundation loadings are significantly different from those
described above, we should be notified to re-evaluate the recommendations presented in
this report.
Site Conditions: The site was vacant at the time of our field exploration. The ground
surface in the building area slopes moderately steep down to the southeast at grades of
about 15 to 20%. There is about 15 feet of elevation difference across the building area.
Vegetation consists of scruboak, grass and weeds. Scattered cobbles are exposed on the
ground surface.
Subsurface Conditions: The subsurface conditions at the site were evaluated by
excavating two exploratory pits in the building area. Pit 2 was located near the septic
disposal area and was also used as the profile pit. The approximate locations of the pits
are shown on Figure 1. The logs of the pits are presented on Figure 2. The subsoils
encountered, below about 1 to 2 feet of topsoil and 21/2 to 3 feet of silty to clayey sand and
gravel, consist of relatively dense, silty sandy gravel with cobbles and boulders to the pit
depths of 6 and 8 feet where refusal to the backhoe was encountered. Results of swell -
Parker 303-841-7119 • Colorado Springs 719-633-5562 • Silverthorne 970.468-1989
-2 -
consolidation testing performed on a relatively undisturbed sample of the sandy clay
matrix, presented on Figure 3, indicate low compressibility under existing moisture
conditions and light loading and a low expansion potential when wetted. Results of
gradation analyses performed on samples of the gravels (minus 5 inch fraction) obtained
from the site are presented on Figure 4. The laboratory test results are summarized in
Table 1. No free water was observed in the pits at the time of excavation and the soils
were slightly moist.
Foundation Recommendations: Considering the subsoil conditions encountered in the
exploratory pits and the nature of the proposed construction, we recommend spread
footings placed on the undisturbed natural soil designed for an allowable soil bearing
pressure of 2,500 psf for support of the proposed residence. There could be some post -
construction foundation movement if the bearing soils become wetted. Footings should
be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and
disturbed soils encountered at the foundation bearing level within the excavation should
be removed and the footing bearing level extended down to the undisturbed natural soils.
Exterior footings should be provided with adequate cover above their bearing elevations
for frost protection. Placement of footings at least 36 inches below the exterior grade is
typically used in this area. Continuous foundation walls should be reinforced top and
bottom to span local anomalies such as by assuming an unsupported length of at least 10
feet. Foundation walls acting as retaining structures should be designed to resist a lateral
earth pressure based on an equivalent fluid unit weight of at least 50 pcf for the on-site
soil, excluding vegetation, topsoil or oversized rock, as backfill.
Floor Slabs: The natural on-site soils, exclusive of topsoil, are suitable to support lightly
loaded slab -on -grade construction. To reduce the effects of some differential movement,
floor slabs should be separated from all bearing walls and columns with expansion joints
which allow unrestrained vertical movement. Floor slab control joints should be used to
reduce damage due to shrinkage cracking. The requirements for joint spacing and slab
reinforcement should be established by the designer based on experience and the intended
slab use. A minimum 4 inch layer of free -draining gravel should be placed beneath
basement level slabs to facilitate drainage. This material should consist of minus 2 inch
aggregate with less than 50% passing the No. 4 sieve and less than 2% passing the No.
200 sieve.
All fill materials for support of floor slabs should be compacted to at least 95% of
maximum standard Proctor density at a moisture content near optimum. Required fill can
consist of the on-site soils devoid of vegetation, topsoil and oversized rock.
Underdrain System: Although free water was not encountered during our exploration, it
has been our experience in the area that local perched groundwater can develop during
times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can
create a perched condition. We recommend below -grade construction, such as retaining
walls and basement areas, be protected from wetting and hydrostatic pressure buildup by
an underdrain system. ,'
Job No.105 360
-3 -
The drains should consist of drainpipe placed in the bottom of the wall backfill
surrounded above the invert level with free -draining granular material. The drain should
be placed at each level of excavation and at least 1 foot below lowest adjacent finish
grade and sloped at a minimum 1% to a suitable gravity outlet. Free -draining granular
material used in the underdrain system should contain less than 2% passing the No. 200
sieve, less than 50% passing the No. 4 sieve and have a maximum size of 2 inches. The
drain gravel backfill should be at least 11/2 feet deep.
Surface Drainage: The following drainage precautions should be observed during
construction and maintained at all tunes after the residence has been completed:
1) Inundation of the foundation excavations and underslab areas should be
avoided during construction.
2) Exterior backfill should be adjusted to near optimum moisture and
compacted to at least 95% of the maximum standard Proctor density in
pavement and slab areas and to at least 90% of the maximum standard
Proctor density in landscape areas. Free -draining wall backfill should be
capped with about 2 feet of the on-site, finer graded soils to reduce surface
water infiltration.
3) The ground surface surrounding the exterior of the building should be
sloped to drain away from the foundation in all directions. We
recommend a minimum slope of 12 inches in the first 10 feet in unpaved
areas and a minimum slope of 3 inches in the first 10 feet in pavement and
walkway areas. A swale may be needed uphill to direct surface runoff
around the residence.
4) Roof downspouts and drains should discharge well beyond the limits of all
backfill.
Percolation Testing: Percolation tests were conducted on August 28, 2005 to evaluate
the feasibility of an infiltration septic disposal system at the site. Pit 1, excavated
downhill to the south side of the residence, was used as the profile pit. Three percolation
holes were dug at the locations shown on Figure 1. The test holes (nominal 12 inch
diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were
soaked with water one day prior to testing. The soils exposed in the percolation holes are
similar to those exposed in the Pit 1 shown on Figure 2 and consist of 1 foot of topsoil
and 21/4 feet of silty to clayey sand and gravel. The percolation test results are presented
in Table 2. The percolation tests indicate an infiltration rate between 9 and 30 minutes
per inch with an average of 13 minutes per inch. Based on the subsurface conditions
encountered and the percolation test results, the tested area should be suitable for a
conventional infiltration septic disposal system.
Limitations: This study has been conducted in accordance with generally accepted
geotechnical engineering principles and practices in this area at this time. We make no
warranty either expressed or implied. The conclusions and recommendations submitted
in this report are based upon the data obtained from the exploratory pits excavated at the
locations indicated on Figure 1, the proposed type of construction and our experience in
the area. Our services do not include determining the presence, prevention or possibility
of mold or other biological contaminants (MOBC) developing in the future. If the client
Job No.105 360
GeZtech
is concerned about MOBC, then a professional in this special field of practice should be
consulted. Our findings include interpolation and extrapolation of the subsurface
conditions identified at the exploratory pits and variations in the subsurface conditions
may not become evident until excavation is performed. If conditions encountered during
construction appear different from those described in this report, we should be notified at
once so re-evaluation of the recommendations may be made.
This report has been prepared for the exclusive use by our client for design purposes. We
are not responsible for technical interpretations by others of our information. As the
project evolves, we should provide continued consultation and field services during
construction to review and monitor the implementation of our recommendations, and to
verify that the recommendations have been appropriately interpreted. Significant design
changes may require additional analysis or modifications to the recommendations
presented herein. We recommend on-site observation of excavations and foundation
bearing strata and testing of structural fill by a representative of the geotechnical
engineer.
If you have any questions or if we may be of further assistance, please let us know.
Respectfully Submitted,
HEPWORTH - PAWLAK GEOTEC a INC.
Jordy Z. Adamson, Jr., P.
Reviewed by:
Daniel E. Hardin, P.E.
JZA/djb
A10.0 RFQ45.
."'*".*••• Ate(
9707
kikkx
attachments Figure 1— Location of Exploratory Pits and Percolation Test Holes
Figure 2 —Logs of Exploratory Pits
Figure 3 — Swell -Consolidation Test Results
Figure 4 -- Gradation Test Results
Table 1— Summary of Laboratory Test Results
Table 2 — Percolation Test Results
cc: Hepworth-Pawlak Geotechnical, Inc. (Silverthorne) — Attn: Andy Kosse
Schmueser Gordon Meyer — Attn: Clay Goldberg
Job No.105 360
8000
•
7950
1 1
t /
PARCEL 15 11 f
1 /
1 �
PROPOSED 1
RYSIDENCE/
/ PIT
\
PARCEL 16
r
7900/
1 11/ 2 1 1 1 /
_ /
PIT 1 1
/11
8000"
7950
/
7900-
1
/
1
7850
/ / /
/ / /
/ /
/
/ / / /
/ /
�✓� ,/ / I
/ / /
/ / /
7850 ---
•
PARCEL 15
/
1
r
TELEPHONE
EASEMENT
PARCEL 17
PARCEL 19
APPROXIMATE SCALE
1" = 300`
105 360
Hepworth-Pawlak Geotechnical
LOCATION OF EXPLORATORY PITS
AND PERCOLATION TEST HOLES
Figure 1
0
5
10
LEGEND:
PIT 1
ELEV.= 7926
9
WC=13.5
DD=91
-200=57
�I +4=75
-200=7
PIT 2
ELEV.= 794Y
TOPSOIL; sandy silt, scattered gravel, organics, firm, slightly moist, dark brown.
0
10
SAND AND GRAVEL (SM -GM); silty to clayey, dense, slightly moist, light brown, subangular to angular rock
fragments.
GRAVEL (GM); silty, sandy, with cobbles and boulders, dense, slightly moist, reddish brown, subangular to
angular rock fragments.
2" Diameter hand driven liner sample.
_a
Disturbed bulk sample.
_
TPractical digging refusal with backhoe.
NOTES:
1. Exploratory pits were excavated on August 27, 2005 with a Cat 416 backhoe.
2. Locations of exploratory pits were measured approximately by pacing from features shown on the site plan
provided.
3. Elevations of exploratory pits were obtained by interpolation between contours shown on the site plan provided and
checked by instrument level. Logs are drawn to depth.
4. The exploratory pit locations and elevations should be considered accurate only to the degree implied by the method
used.
5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries between
material types and transitions may be gradual.
6. No free water was encountered in the pits at the time of excavating. Fluctuation in water level may occur with time.
7. Laboratory Testing Results:
WC = Water Content (%) -200 = Percent passing No. 200 sieve
DD — Dry Density (pcf)
+4 = Percent retained on the No. 4 sieve
105 360
Hepworth—Po/kik Geotechntcat
LOGS OF EXPLORATORY PITS
Figure 2
0
C
0CZ
CO
o..
E
00
2
4
5
Moisture Content = 13.5 percent
Dry Density = 91 pef
Sample of: Sandy Silty Clay with Gravel
From: Pit 1 at 3 Feet
Expansion
upon
wetting
1
0.1
1.0
105 360
IH
Hepworth—Pawlak Geotechnical
APPLIED PRESSURE - ksf
MV
10
100
SWELL -CONSOLIDATION TEST RESULTS
Figure 3
n
W
Z 30
40
Z 50
Lu
0
CeC'i 60
HYDROMETER ANALYSIS I
TIME READINGS
SIEVE ANALYSIS
U.S. STANDARD SERIES I CLEAR SQUARE OPENINGS
45 MIN.15�MIN. 60MIN19MIN.4 MIN. 1 MIN. #200 #100 #50 #30 #16 #8 #4 318" 314° 1 1/2" 3' 5"6" 8"
�.....YMMI..MMM-M.MM- M....�1E1.-E1-.M.......--.-Y.-=amp ran
..-M-.MM.-.M-M.1M..-. M-MMS—MIONEINWNO 'AM -.MM--
SWIMWEINWIIIIIIVIEV NOM. —.---
.r.......--r•-r.rrr. ..u.M..MNMAMMON M-..rrrr.--
—MMT-.�ININYS•V+'W`- w.."-:•-
.M-.-1...-IWW1 Mnn11111 .Mn ..M•111 ...-.-►AM.-1 Mme.-..1-M.E
IIIWWWWWWAVII .MMEVI-WM/ IOW .M.-MNOWNOW-- -r-.ENI-
OMEN 77/111~1 NM= MI =WNW
11110 N-w.M....-.- M. UM AmmEE..11
rte..-.r.rMVII �— "." w-EV.NSIVWWA —�""..""'
IWOMM—..MM--M--~OM MN IMMO WWINSVAIIWNIVIIWWIL MINIUM ----.
.MMMMINII M-..1.. SAM--.MM-IAM INIONIN 111111111111EMMINI — inn w-... M. -.M - -r-11
MIME VW /WM 60
-.---...-.—i E.... -- AIEE..--MINIM
i.. 111•111W�.....- M- IIIA.M.E.M11.1 ...-�[.M!-n MONO=
WEEMMINItVIONMM.
- N/o�M-=M��....-.1--M- M -
NE
M.VINIIVIR i•-...-1111 MMMT M-".._ MOM--. I.MMI.... MM -MM- MMM -1.
UMNIOWW i 1..-. .-.S..-Mn ..MM..- NONNI '-wW10 ►JM_ aaaa 111.In1A1MA1MF=ma a -MMM.
MIIIIIIWINW AMM MMM-- NWOWel
-MINNWIE _ _ —M --MMI- MM. -k- Mini
.M 1............M M.--. M-.'An.M N'.--1 M -!♦..M.-- ..MMMF
.MMrll-IM.M...-M- irk MV'I..... .MM Mr.. liallmOmm1WIWNEIWPF..M-.f- M111111IIM.{
IN =MIN
//�� —� .Mn= v.AM.M-.r_MM.MMMM.� 1111111111 _--
8
ummer, 1111111110~.
Millil MSM..-- NI, -.,v1.1. ----.
MMIIMMIAA. -MMM.-Iw Milli_ �-A-EM.M.M.IM *HINM--..MMMMM-M..M---- M--.
.MMMMM-M-I— ;,...-M-.M1MMMI..1— a mom .M.-M-pNMMIM-.EImam -
00 ■n---.M.M.MMM.MMMworm > . IIS MMMM-M->AM-.-M.P---p..=�.7...—MMMMMM-�AN11 MIM.IMMM N-.M.-M-.�_M.MM--MM.1-[
--IM.--MMM-MSS.-.MI..-..nMM-.M.-[ :�:w�N .-F--- IWNINI )0W4nWatii ISIMIR OR IMINININV
.-.MM.1VWFWMOIWINV .--M.--I-I-/-IIIIIN 1111 fMM."..,,,.R MtWOW ---...fNNIIIIIIN�[LIX=
-r--__
.Mi =MI rMMMMM-WVIIVNINESINI MM..- - MMAMII
NM NM.M--..M1MM IN Mr -..r rimM I- INOWNI f
10
20
70
90
00
70
NNW 11111.11111111111111M iwwwimw
100
MEMMIEWEVIO NO
E-r1.�i.-w- OMWWWWWW11 1111111111
M•11 M..M...EW-1.M-.
.001 .002 .065 .009
.019 .037 .074 .159 .600 1.18 2.36
DIAMETER OF PARTICLES IN MILUMETERS
4,75 9.5 12.5 19.0
37.5 762 152 203
127
C I AYTO50_T
FINE
GRAVEL 75 %
LIQUID LIMIT %
SAtED GRAVEL
MEDIUM (COARSE 1 FINE j COARSE
SAND 18 %
comes
SILT AND CLAY 7 %
PLASTICITY INDEX %
SAMPLE OF: Slightly Silty Sandy Gravel with Cobbles FROM: Pit 1 from 5 to 6 feet
HYDROM1 i ER ANALYSIS SINE ANALYSTS I
TIME READINGS U.S. STANDARD SERIES I CLEAR SQUARE OPENINGS
24 " IR, 7 HR
45 0 VIIN.15 MIN. 60MIN19MIN.4 MIN. 1 MIN. #200 #100 #50 #30 #16 #8 #4 3/8" 3/4" 1 1/2" 3" 5°6" 80
10
20
30
40
50
60
70
80
90
100
.001 .002
i.
a
r
1-
••••
4
50
40
30
20
10
0
'ER EN 'A [�
90
80
0
70 Z
co
60 cl
1✓
50 Z
LLI
0
40 CC
n..
30
20
10
0
.005 .009 .019 .037 .074 .150 .300 .600 1.18 2.36 4.75 9.512.519.0 37.5 76.2 12552 203
DIAMETER OF PARTICLES IN MILLIMETERS
CLAY TO SU
FINE
51067 GRAVEL
MED .M (COARSE FINE 1 COARSE I
COBBLES
GRAVEL 52 %
LIQUID LIMIT %
SAMPLE OF: SII Sand Gravel with Cobbles
SAND 23 % SILT AND CLAY 25 %
PLASTICITY INDEX %
FROM: Pit 2 from 7 to 8 Feet
105 360
Hepworth-Powlak Geotechnlcol
GRADATION TEST RESULTS
Figure 4
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE 1
SUMMARY OF LABORATORY TEST RESULTS
Job No. 105 360
SAMPLE LOCATION
NATURAL
MOISTURE
CONTENT
(%)
NATURAL
DRY
DENSITY
(pCf)
GRADATION
PERCENT
PASSING
NO. 200
SIEVE
ATTERBERG LIMITS
UNCONFINED
COMPRESSIVE
STRENGTH
(PSF)
SOIL OR
BEDROCK TYPE
PIT
DEPTH (ft)
GRAVEL
(%)
SAND
(%)
LIQUID
LIMIT
(%)
PLASTIC
INDEX
(%)
1
3
13.5
91
57
Sandy Silty Clay with
Gravel
5 to 6
75
18
7
Slightly Silty Sandy Gravel
with Cobbles
2
7 to 8
52
23
25
Silty Sandy Gravel with
Cobbles
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE 2
PERCOLATION TEST RESULTS
JOB NO. 105 360
HOLE NO.
1
HOLE DEPTH
(INCHES)
LENGTH OF
INTERVAL
(MIN)
WATER
DEPTH AT
START OF
INTERVAL
(INCHES
WATER
DEPTH AT
END OF
INTERVAL
INCHES)
DROP IN
WATER
LEVEL
(INCHES)
AVERAGE
PERCOLATION
RATE
(MIN./INCH)
!�
P-1
40
15
Water added
Water added
81/4
31/4
9
81/4
5
31/4
101/4
8
21/4
8
53/4
21/4
53/4
4
13/4
9
61/2
21/2
61/2
43/4
13/4
43/4
3
13/4
• P-2
30
15
101/2
9
11/2
i
I
27
9
73/4
11/4
73/4
63/4
1
63/4
6
3/4
6
51/4
3/4
51/4
45/8
5/8
4'/8
4
'/8
4
31/2
1/2
P-3
40
15
11
91/4
13/4
30
91/4
73/4
11/2
73/4
63/4
1
63/4
6
3/4
6
51/4
3/4
51/4
43/4
1/2
43/4
41/4
1/2
41/4
33/4
1/2
Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on
August 27, 2005. Percolation tests were conducted on August 28, 2005. The average
percolation rates were based on the last two readings of each test.
S"C:HMUI'=SER GORDON ; MEYER
E N O 1 N E E R 5 ISURVEYORSS.
February 7, 2007
GLENWOOD SPRINGS ASPEN CRESTED ISUTTE
1 18 W. 6T1a, SUITE 200 P.O. BOX 2155 P.O. 80X 3088
GLENW000 SPRINGS, CO 61601 ASPEN, CO 8161 2 CRESTED BUTTE, CO 51224
970-945-1004 970-925-6727 970-349-5355
FX: 970.945-5948 F7: 970-925-4157 >=x: 970-349-5358
GARFIELD COUNTY ED
BUILDING. AND PLANNING DEPARTMENT
108 8th Street., Ste. 401 FEB 1 2007
l
Glenwood Springs, CO 81601 GARS ; ;;:r COUNTY
BUILDING & PLANNING
RE: Eric Schmidt Residence, Garfield County ISDS Permit No. 4163, Certification of Installation
• To Whom R May Concern:
This letter represents a certification of the construction of the Eric Schmidt residence individual
sewage disposal system (ISDS) under Garfield County Building and Planning Department Septic
Permit No. 4163. The permit was issued based on engineered plans and specifications prepared
by Schmueser Gordon Meyer, Inc. with a revision date of October 20, 2005. The ISDS design at
the Schmidt residence, 1137 High Aspen Drive (Lot 16 of the High Aspen Ranch), was configured
as four trenches fed by treated wastewater routed through a 2,000 -gallon septic tank.
I inspected the installation of the septic tank, collection system, flow splitter and gravelless chamber
trenches pursuant to our original plans and specifications. My inspection during the construction
process indicated that the system was installed in a manner consistent with our planset with a few
variations. First, the original design was for the old Standard H-10 infiltration chambers, which are
no longer available. Quick4 chambers were actually installed. The required absorption area was
810 square feet (SF). The Quick4 chambers have an effective area of 9.87 SF per chamber unit in
a trench configuration. This results in a need for 82 chamber units. The actual installation included
3 trenches with 21 chamber units and 1 trench with 20 chamber units, for a total of 83 chamber
units.
Our original design called for a polylok distribution box with equalizers at each pipe opening. The
contractor had installed a concrete distribution box with no equalizers. The box appeared to be
level and was placed on compacted gravel. The contractor later verified with water that the box
was level and each pipe received equal flow. Additionally, our original design called for 4"
perforated PVC distribution pipe to run the length of the infiltration chambers. The contractor
installed the chambers without distribution pipe, i.e., solid PVC pipe entered the first chamber and
ended there. This is not unusual for a gravity system and should not be a problem.
I took photographs of the work in progress at the time of my site inspection. As of my site visit, the
I:\2005\2005-415\003 IS)JS\ISIS Cert 020707,dac
septic tank was in place, including the PVC tees at the inlet and outlet, the distribution box had
been leveled, and the excavation crew was in the process of completing the last of the four
trenches. I observed the trenches to be level and showing the appropriate number of chambers as
indicated above. Monitoring pipes were installed on the last chamber unit in each trench.
trust this letter will provide adequate certification of the installation of the Schmidt residence ISDS
pursuant to plans and specifications prepared by our firm. Please feel free to contact me if I may
provide further information or provide you with copies of any of the photographs that were taken
during the course of construction.
Very Truly Yours,
SCHMUESER GORDON MEYER INC.
Matthew T. Webster
cc: Mr. Eric Shmidt
Mr. Kent Cotton, KCE
I:\2005\2005-415\003 ISDS\ISDS Cert 020707.doc
Reviewed by:
W. Hammond, P.E.
Principal, Aspen Office
Ott, u