0145 County Road 225
Rifle, Colorado 81650
Attention:
Subject:
Jeff Parrington
OWTS Design
Lot 4 Creek Side Estates
Rifle, Colorado
Dear Mr. Parrington,
640 White A\cnuc
Grand Junction. Colorado 81501
rhonc: 970-255-8005
Fax: 970·255-6818
Info R huddlcstonbcrr)'.com
October 24, 2016
Project#O 1150-0003
At your request, Huddleston-Berry Engineering & Testing, LLC completed design of an Onsite
Wastewater Treatment System (OWTS) for a single-family residence on Lot 4 of the Creek Side
Estates subdivision in Rifle, Colorado. A site plan is included as Figure I.
Site Description
At the time of the investigation, the site was generally open. The upper (western) portion of the
site was fairly flat; however, the eastern portion of the site sloped down gently to the east.
Vegetation was minimal due to recent site work. The site was bordered to the north and south by
existing residences, to the west by a shared driveway, and to the east by a creek.
Subsurface Investigation
In order to evaluate the subsurface conditions at the site, three test pits were excavated in the
vicinity of the proposed absorption field to depths of between 3.0 and 6.0 feet below the finished
grade. The test pits generally encountered brown, moist, medium stiff silty clayey sand soils
from the ground surface to the bottoms of the excavations. Groundwater was not encountered in
the test pits at the time of the investigation. The soi I profile is shown on the percolation testing
logs included in Appendix A.
Onsite Wastewater Treatment System
Percolation testing was conducted in the test pits in accordance with Garfield County regulations.
The percolation rate in the native soils ranged from 13 to 20 minutes-per-inch, with an average
of approximately 16 minutes-per-inch.
In accordance with Garfield County regulations, a percolation rate of between 5 to 60 minutes-
per-inch is required for the subsurface to be deemed suitable for onsite wastewater treatment.
Therefore, the native soils are generally suitable for onsite wastewater treatment.
Lot 4 Creek Side
#01 ISO·OOOJ @ Huddlmon·Bcn}
l11aWnle1.lrNlti\s,UC:
I 0/24 /16 -
In addition to the percolation rate of the subsurface materials, the seasonal high groundwater
elevation is an important factor in determining the suitability of the site for Onsite Wastewater
Treatment Systems (OWTS). For OWTS suitability, the seasonal high groundwater elevation
should be at least four feet below the bottom of the proposed absorption bed. As indicated
previously, groundwater was not encountered to the depth explored of 6.0 feet at the time of the
investigation. In general, based upon the time of year that the subsurface investigation was
completed, HBET believes that the seasonal high groundwater elevation in the vicinity of the
proposed absorption bed is deeper than 6 .0 feet below the existing ground surface.
Seepage Bed Desig11
The design of the absorption system generally follows the requirements of the Garfield County
regulations. The proposed construction at the site is anticipated to include a five bedroom home.
For conservatism, based upon the soil percolation rate, a Long Term Acceptance Rate (L TAR) of
0.60 will be utilized for the absorption field design . Infiltrator Systems Quick4 Standard
Chambers are proposed in lieu of a conventional gravel absorption bed. The daily flow of the
sewage disposal system is calculated below and a plan and profile of the absorption bed are
shown on Figure 2 .
Average Daily Flow = (5 bedrooms)(2 persons/bedroom)(75 GPO/person)
=750 GPD
Soil Treatment Arca = (750 GPO I 0 .60)"" 1,250 Square Feet
Adjusted Soil Treatment Arca = ( 1,250 SF)( 1.2)(0. 7) = 1,050 Square Feet
#of Quick4 Chambers= ( 1,050 I 12) = 88 Chambers
System ll1stal/atio11
The installation of the septic tank , plumbing lines, Infiltrators, etc. should be completed in
accordance with Garfield County regulations and Infiltrator Systems, Inc. specifications. In
addition , the following construction procedures are recommended:
• The septic tank and distribution box should be placed level over native soils that have
been scari fled to a depth of 8 to 12 inches, moisture conditioned, and recompacted to
a minimum of 95% of the standard Proctor maximum dry density, within ±2% of
optimum moisture content. However, up to 3-inches of washed rock or pipe bedding
passing the I-inch sieve may be used as a leveling course under the septic tank and/or
distribution box.
• The bottoms of trenches and backfill around the septic tank and distribution box
which will support sewer or efnuent lines should be compacted to at least 90 percent
of the standard Proctor maximum dry density, within ±2% of optimum moisture
content. Pipe bedding should have a maximum particle size of I-inch.
• Ve hicular or heavy equipment traffic and placement of structures should not encroach
within I 0 feet of the septic tank or distribution box.
X ~008 ALL PROIECTS '.01130 ·Tolly llo Conmu<tKJn'Ol lSO.DOOJ Lot~ C1cel11de'?OO • G<o'.011 SO-OOOJ LRIO?llo do< 2
Lot 4 Cn:ck Side
#01150-0003
10124 116
Inspection Scltedu/e
® Huddlfflon·Bcm-
""'Wns.1.a ,.,........_.._., .
Huddleston-Berry Engineering & Testing LLC should be retained to monitor the construction of
the OWTS. The following schedule of observation and /or testing should be followed :
• Observe the absorption bed excavation prior to placement of Infiltrator chambers.
• Observe placement of the septic tank , distribution box , and all connecting sewer and
effluent Jines prior to backfill. Verify proper fall between inverts.
• Observe and verify installation of the absorption bed prior to placement of cover and
backfill.
In conformance with Garfield County regulations, HBET will be required to provide Garfield
County with documentation certifying that the OWTS was placed in conformance to the plan and
profile and Garfield County regulations.
General Notes
The OWTS design was based upon the results of the subsurface investigation and on our local
experience . The design is valid only for the proposed construction
We are pleased to be of service to your project. Please contact us if you have any questions or
comments regarding the contents of this report.
Respectfully Submitted:
Huddleston-Berry Engineering and Testing, LLC
Michael A . Be rry, P.E.
Vice President of Engineering
X lOOS ALL PROJECTS'·Ol 150 ·Tolly !lo ConstructK>n'.Ol l SO·OOOl Lot 4 Crcc~sode\200 • Geo'.01150.(JOOJ LRIOll 16 do c 3
FIGURES
'•
-I -·--: I . . ... ...,_, .. .,., ---: -····· ..... _ ·-. ·------' :' ·~.:~.--,-~~·---:~~: .. \"'--'~-~ -----~-~. Ll~~~~.:·.=:~.~-:, ........ ----····· ·--·--· ····--1
_../ ··\~";----~--:o.·----·--; -~-· ------TP·~~. "\~P-2 ·... :,
.. ' " ' ..... '> .,
. .-/\ TP-3~ .· ,
. i . ,. \ » Absorption Beds , . ! ' A ' :
/ ' . .--. ..... , ' : .. : ..--, ·-'-. I
....
...............
.-. ~ , , .... : . .-· < '. ' : -· '
' ---' ' i. ___ ,... ' /
:: .-----' /
........... ........ · .. ·.
'•. · . . '•
'·.. ---' , ··----~ ... ............... ..._ ___ .,.,.,-
',
......... · ......... Replacement Area
........... ·-. ·,_
.........
'• ·-.
~ . ... .......... .. _
'· .,_
'·. "· ' ......
·····-... _
· ........
'• .. ,
'· ................. '
"' ... !
TALLY HO CONSTRUCTION INC
,-.. Cl.UI"-~ ....
"""'""' .... ~.r"l~Mof . .......... .:.__ . .,......._~.
~
&
!
FIGURE 1
Site Plan
JEl"' P ... R"11"6TON 11tESID ENCE
~•~l~U·•Tt1
11r..sc:.:::t-.~
""" _..,_. _J Cl.I
J_
j fTt.•AAPl"k.l'L
·~·
I
-.on
'~"~,.,
lJIM
ABSORPTION BED PROFILE
GkA.0£ 10 O~.\IS A~'AY rRO\t om
;:UUOl!Stt \ £GfTATl\<:CO\f•
MO! IOSCALE
Pl"{'~F'ILL \tl\nRJAt
• 'lAlf\·t.:.oA
F '-GINUit .\f'f'~O\'lO AL lJ.l'; • .\Tl\'£
~
~~~~~~~~~~~~-t-~~~~"41fTMN~~~~o+-~~~~~~~~~~~-
GENERALIZED SYSTEM PROFILE
ABSORPTION BED PLAN
SCALE (FT) rs----!
0 2 4 6 s 10 '>()
RtSIDE'HIAL
~TRLcnO\£
~ISE!l5 iAS XECF.S§ARYr
5l1Cll TllA T LID~ ARE AT OR
,\UO\'E 1 lt-.ISllf.0 G RAD !:
.en·.c1t.co..-o JI [ '''G'-I ! , ' ' o·u•rt.t.-CJ>.Tu~-u L=?~Y~•.::d .,... .. U.'-C"
r~ ,.,
&l .,,
'it.Im: I'"''-
!':Fil rRA TOR ~ YSTT MS QUICK•
ST A 'DARO C!IAMDtR S
e-~~~~~~~~~-~an MN~~~~~~~~~~~
OISTRIUL'TI OX DOXF.S THAT f>;Sl!RE
F.Vr.N OISU IRrmo~ or r.rFl.t;f""T \
•-l"Cll OIAMf.T(R Sf\\ I 'l
""Dfrtll r~.rM?F.
\ll.l.l I"-<. A~H.I U17i~.
/ /SCllH>t.lf.'IJOR SUR H Ir ~,,__,, .. ,,, .. _
, I _.....__. ----4
SEMlC TAt.:K llR C'O~IDINA TIO~; llf TA -.;1(5
W!TJI \U:-;l'.tl \! l .!OOCAllC'XC\P,\CITY
Project No.: 01150-0003
Date: !Of24 f l6
By: MAB
RESIOEl\TIAL
STRLClt;RE
Hudd.leston-Bcrr:r
[n~:n-:-t r:,1::,,': T;:~riti.~. tt.C
6-111 White A"e11ue. Lnit [I
Grand Junchon. CO 81 SO I
N;ILHtA JOR: <llAMUlMr.;
urs11un11no' oo~·.· \ ,,,,
""l 0 fi OLLOW f.\ISTl."IG GkAl)! \t •:I. •·
LOT ·I CREEK SIDE
FIGCRE 2 -SEPTIC SYSTE~I
PLAN A'.'lD PROFILE·
APPENDIX A
Percolation Testing Results
PERCOLATION TESTING
Project No . 01150 -0003
Test Pit No . TP-1
Project Name: Lot 4 Creekside Estates Location : Rifle, CO Date : 1011012016 ~~~----~~1b::=====================:!l
Testing Conducted By: C. Miller Supervising Engineer: M. Berry --'--------_____ ....._ _______ _
Pit Dimensions: Length ; Width Depth 3 Ft -------Water Level Depth : Not Encountered X
SOIL PROFILE
Depth Description
0-3 Ft Silty Clayey SAND (sc), brown, moist , medium stiff
Test Number : 1
Top of Hole Depth : 3-Ft
Diameter of Hole : 16-in.
Depth of Hole : 20-in.
Water
Time Depth Change
(min .) (in .) (in.)
0 2.25
5 2.875 0.625
10 3.5 0.625
15 4.1 25 0.625
20 4.625 0.5
25 5 0.375
30 5.375 0.375 -
3 5 5.75 0.375
4 0 6.125 0.375.
4 5 ~ 6.5 0.375
50 I 6.875 0.375
55 ' 7.25 0.375
60 7.5 0.25
Rate (min/in): 14
Average Percolation Rate (min/in):
Test Number:
~...,..-----Top of Hole Depth :
Diameter of Hole: ---
Depth of Hole :
Water
Time Depth Change
(min.) (in .) (in .)
Rate (min/in):
Remarks
Test Number: ,...--...,......----
Top of Hole Depth : ----
Diameter of Hole :
Depth of Hole:
Water
Time Depth Change
(min.) (in.) (in .)
Rate (min/in):
PERCOLATION TESTING
Project No. 01150 • 0003
Test Pit No . TP-2
Project Name: Lot 4 Creekside Estates Location: Rifle, CO Date: 10/10/2016
~~~--~~-i=================:=!!
Testing Conducted By: __ c_._M_il_le_r _____ Supervising Engineer: __ M_._B_e_rry......_ _______ _
Pit Dimensions: Length ; Width ; Depth 6-ft -------W ater Level Depth : Not Encountered X
SOIL PROFILE
Depth Description
0-6 Ft Silty Clayey SAND (sc), brown, moist, medium stiff
Test Number: 1
Top of Hole Depth : 6-Ft
Diameter of Hole : 16-in.
Depth of Hole: 16-in.
Water
Time Depth Change
(min .) (in .) (in.)
0 1.75
5 2.375 0 .625
10 2 .75 0 .375
15 3.125 0.375
20 3 .5 0.375
25 3.75 0 .25
30 4 0 .25
35 4.25 0 .25
40 4.5 ,0 .25 ~
45 4.75 0 .25
50 5 0 .25
55 5.25 0 .25
60 5 .5 0 .25
Rate (min/in): 20
Average Percolation Rate (min/in):
Test Number:
~-,-----Top of Hole Depth :
Diameter of Hole : ---
Depth of Hole :
Water
Time Depth Change
(min.) (in .) (in .)
Rate (min/in):
Remarks
Test Number: ------Top of Hole Depth : ___ _
Diameter of Hole:
Depth of Hole :
Water
Time Depth Change
(min .) (in.) (in.)
Rate (min/in):
•
PERCOLATION TESTING
Project No. 01150 -0003
Test Pit No. TP-3
Project Name: Lot 4 Creekside Estates Location: Rifle . CO Date: 10/10/2016 ~~~-'-~~"f'======:ii============ll
Testing Conducted By : __ c_._M_il_le_r _____ Supervising Engineer: __ M_._B_e_rry.._ _______ _
Pit Dimensions: Length ; Width Depth 3.5 Ft -------Waler Level Depth: Not Encountered X
SOIL PROFILE
Depth Description
0-3.5 Ft Silty Clayey SAND (sc), brown, moist. medium stiff
Test Number: 1
Top of Hole Depth: 3.5-Ft
Diameter of Hole: 16-in.
Depth of Hole: 18-in.
Water
Time Depth Change
(min .) (in.) (in.)
0 1.75
5 2 .5 0.75
10 3 .25 0.75
15 3.875 0 .625
20 4 .375 0.5
25 4 .875 0 .5
30 5.375 0.5
35 5.875 0.5
40 6 .25 0 .375
45 6.625 0 .375
50 7 0.375
55 7.375 0.375
60 7 .75 0 .375
Rate (min/in): 13
Average Percolation Rate (min/in):
Test Number: ------Top of Hole Depth :
Diameter of Hole: ---
Depth of Hole :
Water
Time Depth Change
(min.) (in.) (in .)
Rate (min/in):
Remarks
Test Number: ------Top of Hole Depth :
Diameter of Hole: ----
Depth of Hole :
Water
Time Depth Change
(min .) (in .) (in .)
Rate (min/in):