HomeMy WebLinkAbout03924• GARFIELD COUNTY BUILDING AND SANITATION DEPARTMENT 109 8th Street Suite 303 Glenwood Springs, Colorado 81601 Phone (303) 945-8212 INDIVIDUAL SEWAGE DISPOSAL PERMIT PROPERTY SYSTEM DESIGN ______ Septic Tank Capacity (gallon) ______ Other ______ Percolation Rate (minutes/inch) Number of Bedrooms (or other) ____ _ Required Absorption Area -See Attached Special Setback Requirements: Permit N~ 3924 Assessor's Parcel No. This does not constitute a bu1ld1ng or use permit. Date _____________ Inspector ___________________________ _ FINAL SYSTEM INSPECTION AND APPROVAL (as installed) Call for Inspection (24 hours notice) Before Covering Installation System Installer ________________________________________ _ Septtc Tank Capacity ______________________________________ _ Septic Tank Manufacturer or Trade Name Septic Tank Access within 8" of surface -------------------------------- Absorption Area----------------------------------------- Absorption Area Type and/or Manufacturer or Trade Name -------------------------- Adequate comphance with County and State regulat1ons/requ1rements _____________________ _ Other -------------------~---,------------,,-.---------- Date --'-'Ck=-'-:__~_/ O_.-~Zoc_..o.__> c/'---1 nspe ctor __jQ.._,;i,.,LLJU...., ..... .J,,,_"-'cfu.-.-uW<i~JZ:clk'.._,,Jt...£4,_,,.· k~--1c_,,,~~c.L-'"·--- RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE •CONDITIONS: 1. All installation must comply with all requirements of the Colorado State Board of Health Individual Sewage Disposal Systems Chapter 25, Article 10 C.R.S. 1973, Revised 1984. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements Con- nection to or use with any dwelling or structures not approved by the Building and Zoning office shall automatically be a violation or a requirement of the permit and cause for both legal action and revocation of the permit. 3. Any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications contained in the application of permit commits a Class I, Petty Offense {$500.00 fine -6 months 1n ia11 or both). White. APPLICANT Yellow -DEPARTMENT INDIVIDUAL SEWAGE DISPOSAL SYSTEM APPLICATION PHONE ~7151/!Yj PERMIT REQUEST FOR (,,-1 NEW INSTALLATION ( ) ALTERATION ( ) REPAIR Attach separate sheets or report showing entire area with respect to surrounding areas, topography of area, habitable building, location of potable water wells, soil percolation test holes, soil profiles in test holes (See page 4). LOCATION OF PROPOSED FACILITY~/} Near what City of Town._.._b-""-'i'-"h'>=':...,...,="'""L'----------~-Size of Lot Legal Description or Address !'0J 6','?/U1Hvu. /{v,,,:/ ,U WASTES TYPE: ~WELLING ( ) TRANSIENT USE ( ) COMMERCIAL OR INDUSTRIAL ( ) NON-DOMESTIC WASTES BUILDING OR SERVICE TYPE:_&._,_/_·c.~'/~~~hr~fr+--"-"-.,~/_· ------------- Number ofBedrooms __ 5~ _________ Number of Persons __ ?--___ _ )/f' Garbage Grinder ~Automatic Washer _JADishwasher SOURCE AND TYPE OF WATER SUPPLY: ~LL ( ) SPRING ( ) STREAM OR CREEK If supplied by Community Water, give name of supplier: DISTANCE TO NEAREST COMMUNITY SEWER SYSTEM: ------------- Was an effort made to connect to the Community System?--------------- A site plan is required to be submitted that indicates the following MINIMUM distances: Leach Field to Well: 100 feet Septic Tank to Well: 50 feet Leach Field to Irrigation Ditches, Stream or Water Course: 50 feet Septic System (septic tank & disposal field) to Property Lines: 10 feet YOUR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT WILL NOT BE ISSUED WITHOUT A SITE PLAN. GROUND CONDITIONS: Depth to first Ground Water Table _______________________ _ Percent Ground Slope ___________________________ _ TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: yJ SEPTIC TANK ( ) AERATION PLANT ( ) VAULT ( ) VAULT PRIVY ( ) COMPOSTING TOILET ( ) RECYCLING, POTABLE USE ( ) PIT PRIVY ( ) INCINERATION TOILET ( ) RECYCLING, OTHER USE ( ) CHEMICAL TOILET( ) OTHER-DESCRIBE FINAL DISPOSAL BY: M ABSORPTION TRENCH, BED OR PIT ( ) EV APOTRANSPIRA TION ( ) UNDERGROUND DISPERSAL ( ) SAND FILTER ( ) ABOVE GROUND DISPERSAL ( ) WASTEWATER POND ( ) OTHER-DESCRIBE WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? ---- PERCOLATION TEST RESULTS: (To be completed by Registered Professional Engineer, if the Engineer does the Percolation Test) Minutes ____ _,..er inch in hole No. 1 Minutes ------.Per inch in hole No. 3 Minutes _____ per inch in hole No. 2 Minutes per inch in hole No._ Name, address and telephone ofRPE who made soil absorption tests:-------------- Name, address and telephone ofRPE responsible for design of the system: Applicant acknowledges that the completeness of the application is conditional upon such further mandatory and additional tests and reports as may be required by the local health department to be made and furnished by the applicant or by the local health department for purposed of the evaluation of the application; and the issuance of the permit is subject to such terms and conditions as deemed necessary to insure compliance with rules and regulations made, information and reports submitted herewith and required to be submitted by the applicant are or will be represented to be true and correct to the best of my knowledge and belief and are designed to be relied on by the local department of health in evaluating the same for purposes of issuing the permit applied for herein. I further understand that any falsification or misrepresentation may result in the denial of the application or revocation of any permit granted based upon said application and in legal actio for erjury as provided by law. FROM : / FAX t-0. J'P· 08 2004 09:56AM P1 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS June 25, 2004 Structural Associates Building Contractors Attn: Bruce Shugart 4185 County Road 154 Glenwood Springs, Colorado 81601 Subject: Subslllface Investigation and OWS Design, Proposed Residence Lot 6, Farynhyll Ranch Garlield County, Colorado Job No. 16446 Mr. Shugart, As requested, we have investigated subslllface conditions and <lesigned an onsite wastewater system (OWS) for the proposed residence. The subsutface investigation was performed on May 27, 2004. SITE CONDITIONS The Jot is located in a rural residential area in Garfield County, Colorado, where OWS arc required. The proposed drain field area has a 15% to 20% slope to the east. There is a moderate cover of native grasses and weeds. A stream exists on the property to the southeast of the proposed drain field area. Water is provided to the residence by a well located 146+ feet from the proposed drain field area. PROPOSED CONSTRUCTION A five-bedroom residence and 2-bedroom amenities building are proposed as indicated on Figure I. In accordance with the Individual Sewage Disposal System (ISDS) regulations, the average sewage loading for seven bedrooms is lOSO Gallons Per Day (GPO) and 1S7S GPO with a 1.5 peaking factor. This load- ing includes a dishwasher, garbage grinder, and washing machine. If additional bedrooms in unfinished anias are possible, it is suggested the OWS be constructed to serve the added loading. The installation of an engineered OWS to serve future build-out can be cost effective. SUBSURFACE CONDmONS The subsurface investigation was performed by digging three percolation holes, 34 to 42 inches deep, and one te$t pit at the locations indicated on Figure 1. Subswface materials in the test pit consisted of 2 feet of silty, sandy clay underlain by cobbles and small boulders in a sandy clay matrix to the maximum depth explored of 6 feet. No ground water or bedrock was encountered. The drain field may be installed no deeper than 2 feet unless an 8-foot test pit is dug to confirm soil conditions. The test pit may be dug at the ti~e of installation. If no bedrock or ground water is encountered to 8 feet, then the drain field may be installed at a maximum <lepth of 4 feet. Percolation tests indicate percolation rates of 27 DEHVER 4501 WadeWOfth BouleYard Whoot Ridge, CO 80033 303.483.8317 Fax: 303.483.~1 www.geo .. church.oom Toll frH • 1 .87'T .248.31 Z! .FRlJ1 : FAX NO. ~p. 08 2004 09:57AM P2 OWSDe.~ign Job No. 16446, 6n5104 Page 2 to 40 minutes per inch (MPI). The average percolation rate is 36 MPI. Percolation dam is presented in Table 1. RECOMMENDATIONS The installation must include two septic tanks, an effluent pump, and a gravelless chamber-trench drain field at the locations presented on Figure 2. The OWS design is based on an average sewage load of 1050 GPD and a percolation rate of 36 :MPI. The installation must include a 1250-gallon, single-compartment, concrete septic tank followed by a 1000-ga!Jon, two-compartment, concrete septic tank with a Biotube® pump vault in the second compartment. If gravity flow to the drain field can be achieved, our office should be contacted for design specifications. Six chamber-trenches must be installed, each .with one row of 11 chambers for a total of 66 chambers and 1023 ft 2 of infiltrative area. The trenches may be modified to confonn to topography and to preserve as much vegetation as possible, A flow splitter basin, or equivalent, is :required to distribute effluent to the field. Movement over the drain field trench during construction should be kept at a minimum to minimize compaction of the receiving soils. The bottom of each trench must be scarified with a pick, shovel, or backhoe bucket teeth prior to the addition of chambers. The surface of the drain field should be seeded after installation of the system. A native seed mix from the area available at seed stores should be used. These mixes do not require irrigation and develop a growth 10 to 15 inches high. No automatic sprinkler system should be installed over the field OPERATION AND MAINTENANCE The owner must realize an OWS is different from public sewer service and must assume the responsi- bility for maintenance of the OWS. The system is relatively maintenance free, but the owner must have the septic tanks pumped. 1n the absence of a monitoring program, the septic tank should be pumped and the effluent filter cleaned every two years. There are daily considerations, such as not putting plastic or other nonbiodegradable material into the OWS. Water use must be monitored so toilets are not allowed to run when seals malfunction. To illustrate the point, a running toilet can consume in excess of 1000 GPD. A loading of 1000 GPD could flood and irreparably harm the OWS. The loading from the backwash of a water softener may be harmful to the OWS. A separate drywell should be constructed for the backwash waste, if a softener is installed. Chemically treated water from a swimming pool or spas should not be introduced to the OWS. LIMITATIONS An OWS design requires installation by a licensed contractor. Our investigation, layout, design and recommendations are based on data submitted. If conditions different from those described in this report are encountered, we should be notified to evaluate the effect on the proposed OWS. If the health depart- ment modifies this design, we should be contacted to evaluate the impact on the performance of the ows. All construction is to be in accordance with the ISDS regulations. Pipe type and size, burial requirements, septic tank construction, and other specifications, which are not depicted in our report, are to conform to the requirements of the ISDS regulations. The installer of the system is to have demonstrated knowledge of the ISDS regiilations and requirements. ,FROM : FAX f'{], bp. 08 2004 09:57AM P3 OWSDesign fob No. 16446, 6125104 Page 3 If there are questions or if we Cllll be of further service, please call. CIIDRCH & Associates Inc. EricR.Bums Design Technician SDU/erb 3 copies sent via Priority Mail Reviewed by: Samuel D, Urton, P .E. FROM : FAX NO. ~p. 08 2004 09:57AM P4 LOT 6, FAYRNHYLL RANCH GARFIELD COUNTY, COLORADO EXISTING DRIVEWAY BUILDING ENVELOP~.~ /' _,,,/ /' //' I / I I I PRDPdSED 5-BEDROOM \ RESIDENCF--...- \ \. \. "-· 15% -20% SLOPE P-Z P-3 00 '0 P-1 L TEST PIT "'-·'-............... ,/ .......... ./ JOB NO. 16446 ·------·-·-·-· SITE PLAN AND LOCATION OF PERCOLATION HOLES SCALE 1" =: 100' FIGURE 1 FROM : FAX 1-V. LOT 6, FA YANHYLL RANCH GARFIELD COUN1Y, COLORADO ¢ / --·-_/.-f OBSERVATION/VENT PIPES (TYP.) 1023 SF OF INFILTRATIVE AREA IN A GRAVELLESS CHAMBER-TRENCH DRAIN FIELD. EACH TRENCH MUST EXISTING DRIVEWAY-- HAVE ONE ROW OF II CHAMBERS FOR A TOTAL OF 66 CHAMBERS. FLOW SPLITTER BASIN (OR EQUIVALENT) 2" PVC PUMP LINE ·----·----·-............. ~ ~p. 08 2004 09:57RM P5 SCALE 1" "' 60' I) DRAIN FIEl.D MUST BE LOCATED A MINIMll"\ OF l4b' FROM WEl.L.S ANO 96' FROM SlJIFACE WATER (IE. STREAM OR ~ONO). IF PONDS OR STREAMS ARE LINl!D THE SETBACK IS REDUCED TO 10'. Z) SEPTIC TANKS ANO SEWAGE LINES MUST BE AT LEAST 10' FROM WATER \.INES. 3) SEWAGe LINES LOCATED WITHIN SETaACK TO WATER LINE'S MUST BE ENCASED WITH SCH 40 PllC PIPE WITHIN 10' OF CROSSING. 4) CHURCH & ASSOCIATES, INC. S!iOWl BE NOTIFIED FOR DESIGN SPECIFICATIONS IF GRAVITY FLOW (MINIMIJM OF 118' PER FOOT DROP) CAN BE ACHIEVED FROM SEPTIC TANKS TO DRAIN FIELD. 1250-GALLON, SINGLE-COMPARTMENT, CONCRETE SEPTIC TANK FOLLOWED BY 1000-GALLON, TWO- COMPARTMENT, CONCRETE SEPTIC TANK WITH A PUMP IN A BIOTUBE(R) PUMP VAU... T IN THE SECOND COMPARTMENT. _ _...,ROPOSED 2-BEDROOM AMENITIES BUILDING \ I FIGURE 2 l'l'PICAL Pu.N VIEW -N. T.S. 2" Pl/C PUMP LINE----....._ <f." PllC HEADERS TO ~ GRAmtESS CHAlllllER 3' BY 6.25~ 4" SllR JS PVC O!ISERVA110N/\'fNT PIP g• ~IN. 0 0 0 foo-~~~~~~~~~~~~~-e11.7s~·~~~~~~~~~~~~~-.i TIPICAL CROSS-SECllON -N.T.S. I• II" MIN,....---.il / SIX TOTAL 1RENCHES 4" SDR Jll Piie CllSEJIYAllOH}'.efT PPE M1li CAP ftOWSl'UJ'ID.•U!N FOR GBAVl'lT n.ow Enl.1JEN'I' - --~ ~~ ... .,,_~ ~ u..----- ~-- ~ ~ ~ r I OOEN1 OF EXCAVAllt>I GRA~. ~~~ tu::\ I l . l m...-• -•N..L~i..<::v~ I /N CALCULAllONS AND SPECIFlCAllONS llESIGlf CRJlaUA S1RUC1\JRES = 7 BEOROOMS LOADING -q ... 1050 GPO PERCOLATION lEST -t -36 MPI AREA -((1.s x q)>c oqrt t) / 5 AREA -11!!!<l SF REDUCTION ftlll USE OF CHAMBER-TRENCHES • 50ll TOTAi. AREA -945 SF JOB NO. 16446 1RDICll sPECIFICATIOHS NUMBER OF TRENCHES - 6 l£NG1ll OF EACH lRENai -611.7!1 FEET, 11 CHAMBERS lllDlll OF EAai TRENai -3 fE£T. 1 CHAMBER roTAL NUMBER OF CHAMBERS • 66 CHAMBERS roTAI. AREA -1023 Sf DRAIN FlELD DETAILS lR£ATllENT UNIT SPECflCATIONS TOTAL MINIMUM CAPAaTY 2 2000 GAi.LOOS llECllMMENOATI<lN -alE 1250-G.\l.UJN, SINGLE-CllMPARlYENT. CONCRETE SEPTIC TANK FOl.LOllfJl BY ONE 1000--GAU.ON. TWO-CCM'ARTMEKT. CONCllElE SEPTIC TANK WllH A PUMP IN A ~) PUMP VAULT IN 1H£ SECIND COMPARTllENT. FIGURE 3 ~ "' UJ ~ dl Pump Selection for a Non-Pressurized System lnputParalN!le<s Des/f1> Aow Rate 311 gpn Oistribullng Vfllve Medel llane Ult to Discharge 10.D feet Transport l.englli :iao.o feet Transpcrl Une Size 2.00 indles Transport Pipe Class.'Sclledllle 4CI llischarge As8smbly Sb& 1.25 inches ~-,--'Add-on' Frfction Losses 0.D -I 1 f Cl i:.iculatlone t::. Head lo8s 1'lvol.V> Dlstrlbuling Valw G.D feet 1 Head loss In Transport Pipe 4.7 fMI :c Hee.d Loss lhtough Discharge 4.5 feet .2 E Head loss Thmugll Flow Meler 0.0 feet :!! 'Add-on' friclion lll6ses 0.0 fael ... Cl TOia! Flow Rate 30.D gpm I ! TDH 19.2 feet {!. ~ ' ·----:--!---t---- Job No. 16446 Figures -,-·; -.---1 ··-;-·-,-- ' ' ' ·' --/. ' ----:....i.... \~ '----'-~ T-::r::=t , i I . ~~ -~ ' -~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-~ ' .... ' .... .:::µ: •M~_~" _ _ , -:; -. ,-c 'C.- ~---.--··· -· -T---· ·-+--~~:±-is;:::~ --:---1208--,- 'P3005 " ' oof-1 I i ; -r---t -~-(-., ' -v .,. .,., ""'<T =t== 60t--t-····r---r -'- -.,---,- . I ' f--+ .L:ts; -+-· ---t--t-~ ' I I~~ ' ~ ~ ~-+:~--+=~mSSJ~ 30~_; ~-~.-i-=g_-__ ris: H ~-I +;.JfEf4FE-a. 00 10 Net Discharge, gpm tenJS• ll•AlllllllAI' AVENUE SIJllDIJl'l flilfGON !l14l9 llllll!IEE: (1Dll348-!11113 TREi'1IJNE: 154\)- IN:SIMllE: 1511le!-28!4 WllfW.Oranco.com .., el 3 .,, ~ ~ r !ti ~ ff! ~ -a --J 1250-Gallon, Single-Compartment, Concrete Septic Tank fOllowed by one 1000-Gallon, Two-Compartment, Septic Tank with an Effluent Pumping System ~ ~ ®·~ Orenc;o Systems• l11tGw1Dd FIBERGLASS GASllETCD LID WITH STAINLESS STEEL BOLTS 81 ~ --.E ~ 2" INSULATION S11HR1Jt. CllEGCJI PVC SPLICE BOX WITH CORO GRJPS 24' DIA. PVC RISER WITH GR<lHMET(S) (J!oNo TO SLOPE GROUND TANK ADAPTER WITH AWAY FRCM RISER RE<Xll11£NDED AlltESIVE) i DISCHARGE ASSEMBLY FLEXllllE »OSE EFFLUEITT DISCHARGE r:!r::: 1L o:l I 1L1 ,..} I L 114" WEEP HOLE 4#j hJ, 0ll .1r:"1 TAN< ADAl'TER (cAST llR OOLTED) LKlUIO LEVEL v INLET TEE OR BAFFLE -l:.:-:,323 &: ~ Fonlgu ~ , 01997, -s,am. Inc. io.-t+-++--LEVEL CONTRCL FLOAT ASSEMBLY o LIQUID LEVEL !dIBd . u H-1--VAULT IN.ET PORTS H-1---FLOW IMJUCER 1+11---OSI EFFLUEITT Pl.Ml' l+lf--FILTER CARTRIDGE CLEAR ZONE OPENING IN iE BAFFLE IS AN ACCEPT llBLE ALTERNATIVE TO PVC TEES ,Y~Jtf--DRAIN PORT ~==========~::!::=====j"--BICJTu111!! PlW VAl.J.T 974-2 lIW'ltttE (541)45&-4449 FAC5IUII: {5t1) 491-- DISCLOSURE: THE PRESIDENT OF CHLJ'lCH B. ASSOCIATES. INC. IS A NON-PARTICIPATING OWNER OF SCG ENTERPRISES, 1NC. WHICH IS A LOCAL DISTRIBUTOR OF ORENCO SYSTEMS. INC. PRODUCTS. THIS DRAWING WAS PROVIDED BY OSI AND HAS BEEN MOOIFIED BY CHURCH FOR THIS PROJECT. lnC. ~ ....... 4501 Wadsworth BoulsYard Wheat Ridge, Colorado 80033 Phona: (3031 '163-931 lYPlCAL 1WO SEPTIC TANK WITH EFFLUENT PUMPING SYSTEM JOB NO. i6446 FIGURE4 ~ ~ !5 Tr '? fil ~ m j CB FROM : PR0·1: HOLE NUMBER 1 2 3 FAX NO. JP· 08 2004 09:59AM pg TABLE 1 ·PERCOLATION TEST RESULTS Lot 6, Farynhyll Ranch Garfield County, Colorado DATE OFTEST: 5127/04 feet deacrlnt•on 0-2 Clav, sen.tu sirtv, medulm stHf, moist. dark brown/orav, root zone 2·6 Cobbles and boulders Ii.iii to 3' dia.l ill a sanrtv, clav matrix. dense, moist. brown NO GROUNDWATER WAS ENCOUNTERED WITHIN EXCAVATION DEPTH TIME DEPTH DEPTH INTERVAL OF HOLE, INTERVAL, START, END, CHANGE, PERC. (INCHES) (MINUTES) (INCHES) (INCHES) (INCHES) RATE (MPI) 36 20 4.13 5.50 1.38 15 20 3.50 4.50 1.00 20 20 3.63 4.25 0.63 32 20 3.25 4.00 0.75 27 20 3.25 3.75 0.50 40 20 3.50 4.00 0.50 40 42 20 3.63 5.00 1.38 15 20 3.13 4.00 0.88 23 20 2.63 3.75 1 .13 18 20 2.75 3.63 0.88 23 20 2.88 3.63 0.75 27 20 3.63 4.50 0.88 23 34 20 4.13 5.25 1.13 18 20 4.00 4.88 O.BB 23 20 3.50 4.25 0.75 27 20 3.75 4.38 0.63 32 20 3.63 4.25 0.63 32 20 3.75 4.25 0.50 40 1·f<1': 1~ , i I < 'I ' I'' ' ' «'I ;)·~ ' . ... ' " ii·~· I 1 '"' I •' 1. •I ,\ I 1 ,I t !• L L d . "' .-~ I ' • • ~ AVG. HOLE PERC. RATE, /Ul>I\ 40 27 40 JOB N0.16446 CHURCH & Associates, Inc. ENGINEERS & GEOLOGISTS December 10, 2004 Structural Associates Building Contractors Attn: Bruce Shugart 4185 County Road 154 Glenwood Springs, Colorado 81601 Subject: Installation Observation, Proposed Residence Lot 6, Faiynhyll Ranch Garfield County, Colorado Job No. 16446 Mr. Shugart, "' .' As requested, we observed the installation of the onsite wastewater system for the subject site on November 13 and December 2, 2004. The system was designed under our Job No. 16446, dated June 25, 2004. The system includes the installation of a 2500-gallon, two-compartment, concrete septic tank with an effiuent filter on the outlet, and six gravelless chamber-trenches. Five trenches have one row of 11 BioDiffiiser® chambers each and one row has eight BioDiffiiser® chambers for a total of63 chambers and 976.5 ft2 of infiltrative area. An as-built drawing will be provided upon receipt ofGPS coordinates. The observed components of the OWS were installed in general conformance with our design. Final electrical connections must be made by a licensed electrician. Our installation observations do not imply a guarantee or warranty of materials or workmanship. If there are questions, please call. Sincerely, CHURCH & Associates, Inc. E~/?._5--~ EricR Burns Field Technician EOC/erb 2 copies sent Faxed to 970-948-0482, Attn: Bruce Shugart Copy to Garfield County Building and Sanitation Department, Attn: Andy Schwaller DENVER 4501 Wadsworth Boulevard Whlll Ridge, CO 80033 303.463.9317 Fax: 303.463.9321 www.geo·church.com Toll Free -1.an .248.3123