Loading...
HomeMy WebLinkAboutAs-Built Evaluation of OWTS 11.2.17H-PVKUMAR 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: (970) 945-7988 Fax: (970) 945-8454 Email: hpkglenwood @kumarusa.com Geotechnical Ëngineering I Engineering Geology Mater¡ais Testing I ÊnvirÕnmental Ofñce Locations: Parker, Glenwood Springs, and Silverthorne, Colorado November 2,2017 Eggers Architecture, Inc. Attn: Don Eggers P. O. Box 798 Kremmling, Colorado 80459 don.e ggers @ eggersarchitecture.com Project No. l7 -7 -263.02 Subject:As-Built Evaluation of Onsite Wastewater Treatment System, Proposed Ranch House, Big Mountain Ranch, 2147 Ute Stock Drive, north of Rifle, Garfield County, Colorado Dear Mr. Eggers: As requested, we observed the installation of the onsite wastewater treatment system (OWTS) installation at the at the subject site as required by the Garfield County Environmental Health Department. Our observations and recommendations for the As-Built evaluation are presented in this report. The services are supplemental to our agreement for professional services to Eggers Architecture, Inc. dated March 28, 2Ol7 . H-PlKumar previously designed the OWTS for the proposed residence submitting our recommendations in a report dated June 23,2417, Project No. l7-7-263.02. The system was designed for three bedrooms. The OWTS was installed by Western Colorado Excavating, Inc. We performed our As-Built evaluation on August 1l, September 22 and November t,2017 . On August 11, the OWTS components observed included: sewer line, cleanout, septic tank, effluent pump, effluent transport line, soil treatment area (STA) and the locations of these components. The installation and locations of the system components were verified as shown on Figure 1. Photographs of the OWTS installation are provided in the attached Photograph Log. At this time, some changes to the STA piping needed to be done and when observed on September 22, adequate corrections to the piping had been made. Power and water were not yet supplied to the OWTS at the time of our inspections. We returned to the site on November I after power and water had been supplied to the pump so a pump performance test could be performed. H-P+KUMAR Project No. l7 -7 -263.02 Don Eggers November 2,20L7 Page2 It is our opinion that the OWTS was installed in general conformance with the above referenced design. The observations and recommendations presented above are based on our site observations and our experience in the area. We make no warranty either express or implied. Alterations to the system or improper backfill and site grading could affect the operation and effectiveness of the OWTS. Please feel free to contact us if you have any questions regarding this letter. Respectfull David A. Young, DAY/kac Attachments: Figure 1 - As-Built Site Plan OWTS As-Built Photograph Log cc:Giard Homes - Roger Giard (roger.giard@giardhomes.com) 8ã-Ëf Itt-¿-t? H-P\KUMAR Project No. 17 -7 -263.02 1,500 GALLEN, THREE CHAMEER VALLEY PRECAST SEPTIC TANK, CLEANI]UT 8t02 8t00 I Toe of Coven Solt Toe of PRNFILE PTÏ 2 AGGREGATE BEÐ THAT IS 65 FEET LI]NG BY 7 FEET VIDË CONSTRUCTIÐ I]VER A E FEET THICK MI]UNDED SANÐ FILTER I ñ a APPRI]XIMATE SCALET 1 INCH = 3O FEET d-t Lollc AS-BUILT SITE PLAN RANCH HOUSE, BIG MOUNTAIN RANCH ó 8fi0 [**-r iiË{î'.tt¿* PRt]FILE PIT 1 PRBPBSED THREE { BEDRnnM RESIDENCE o 17-7-263.4 H-PVKUMAR Fig. 'l OWTS AS.BUILT PHOTOGRAPH LOG PROPOSED RANCI{ HOUSE RESIDENCE 2147 ATE STOCK DRIVE, GARFIELD COUNTY , coLoRADO Photograph 1: Sewer line exiting residence with cleanout and septic tank. Photograph 2: Three chamber, 1,500 gallon Valley Precast septic tank and effluent line. : -.*--.' { {l "') ë "¡*fuL*- ' ? : Proiecl Na 17-79âa ñt O\ry'T'S AS.BUTLT PHOTOGRAPH LOG PROPOST]D RANCH HOUSE RESIDENCE 2T47IJTß, STOCK GARütrLD COUNTY COLORADO i:. Photograph 3: Effluent line running from septic tank to STA. Photograph 4: Effluent line running from septic tank to STA. Proiect No- I 7-7-263.o2 OWTS AS.BUILT PHOTOGR,A.PH LOG PROPOSED RANCH HOUSE RESIDENCE 2I4T TJTE STOCI( DRIVE, GARFIELD COUNTY, COLORADO Photograph 5: STA with aggregate bed, manifolds, laterals, Orenco orifice shields, inspection ports and cleanouts. Photograph 6: STA with aggregate bed, cleanouts, manifold, laterals, O¡enco orifice shields and inspection ports. Proiect No. 17-7-263-02 OWÎS AS.BUILT PHOTOGRAPH LOG PROPOSED RANCH HOUSE RESIDENCE 2M7 ATE STOCK GARFIELD COUNTY COLORADO Photograph 7: STA with aggregate bed and cover soil. Proiect No. 17-7-263.02