Loading...
HomeMy WebLinkAbout10.01 OWTS Capacitybuo- 918 July 12, 2012 Jeff Johnson Johnson Carter Architects,PC 136 East Third St., Suite B Rifle, CO 81650 RE: As -Built On -Site Wastewater Treatment System (OWTS), Bayou Well Services Building Expansion, Parcel 2, Green Subdivision, Rifle, Colorado SE Job No. 11084.01 Dear Mr. Johnson: Pursuant to County Regulations, this letter provides documentation that the new and expanded Onsite Wastewater Treatment System (OWTS) recently installed is in general compliance with the permitted design. Sopris Engineering has performed site visits to measure, inspect, and document the as built conditions of the constructed system. We have coordinated our efforts with the system installer. The systems were inspected prior to backfilling and after component installations were complete. The as -built conditions and installation of the new OWTS components is in compliance with the permitted design specifications for the new and expanded system. The OWTS systems were constructed in accordance with the design recommendations and specifications delineated on the design plan, C-4, Utility and OWS Plan, by Sopris Engineering, dated 8-23-11. The improved site includes a new East side facility addition with plumbed office space that is served by a new OWTS system. The original West side facility and plumbed office space is served by the existing expanded OWTS system. The combined systems were designed based on an average flow of 1520 gpd and a peak sewage flow of 2280 gpd calculated by the per capital usage of employees and transient population. Facility Usage Employees/transient daily Capita Facility description Well Service Truck Maintenance Job desription Office, Shop, Crew Drivers, Transient Existing # Max. 24 -hours Proposed # Total # /capita Usage gpd/cap Avg Rate QA gpd Peaking Factor # Design QD gpd WEST EAST Combined Daily fulltime office 7 14 21 15 315 1.5 472.5 Infrequent parttime Temporary 8 0 8 5 40 1.5 60 Daily fulltime shop 13 13 26 20 520 1.5 780 Max. Daily Transient Crew & Drivers 20 94 114 5 570 1.5 855 Infrequent Guest visitor 2 10 12 5 60 1.5 90 Infrequent Delivery 0 3 3 5 15 1.5 22.5 Existing + Proposed 50 1520 1.5 2280 Design Calculations The design flow is calculated for the subject facilities as shown in the table above based on usage descriptions and per capita flow rates from the State I. S. D. S. Regulations. 502 Main Street • Suite A3 • Carbondale, CO 81623 • (970) 704-0311 • Fax (970) 704-0313 SOPRIS ENGINEERING • LLC civil consultants