HomeMy WebLinkAboutEngineered Pool DesignPalizziPool, 10-6-17Job: L H39 Aspen GlenCrown Jade Design and EngineeringJob No. PLZIl-17648Sheet 51 LayoutScale 1/4" = 1'Þ(ÐctI(v)24',-0"6'-0"7'S"7'€"dimensions of ICF =13'-6" x 25'-6". lnterior waterimensions = 12'x 24'. See51-56 for ICF1 1 NUDURA STANDARD4' FORM UNIT VERTICAL REINFORCEMENT #4@36'O.C. HORIZONTAL REINFORCEMTNT H@32' O.C. PREP COAT B2OOO ACRYLIC PARGE COAT C/W WET COAT P,OOL LINER COVERING 4'EPS15 EXTERIOR OF ICF FOAM FOAM CUT OUT FOR COVED COw/ PARGE cOA RNERS T/POOL LTNER CONCRETE SLABw/ PooL LINER GRANULAR FILL " SLAB W/ EtNro_RcEME_Ì{T #4@12" O.C. ËW UNDER AND EXTERIOR R-VALUES MATCH AT PalizziPool, 10-6-17 Job: L H39 Aspen Glen Crown Jade Design and Engineering Job No. PLZI1-17648 Sheet 52 Footing, Rebar and Foam Detail sTANDARD +" ronM uNr POOL DETAL OF FOOTING REV. REV. DAIE!s-2 ocT 2003 11 l'-0" t H¡ÍçRATEÐ 8ünf-j ¡rvf Ë(HÊJo{p6 v $xr&$trug t'¡lfücr. e " EPS15 UNDER SLAB 1 r- ïlJ?r.K STANDARD Sil INLET/OUTLET FIXTURE BEFORE CONCRTTE POUR EXTRUDE FIXTURE 1/8" (3mm) TO ALLOW FOR PREP COAT B2OOO ACRYLIC PARGE COAT C/w wrr Srr VERTICAL,/HORIZONTAL REINFORÔEMENT AS PER SHEET S2 PalizziPool, 10-6-17 Job: L H39 Aspen Glen Crown Jade Design and Engineering Job No. PLZI1-17648 letSheet 53 lne Detail POOL DEIATL OF INLFr/OUnrr FIXTURE BEFORE POUR No. s-3 ocT 2003 INTFçftATEÛ BUITO!Nç I ECHNQLQçY llttilúing Vsf¿r*;. Ar b/s .l 3,-Þ [?I Brtu L¡-739038Lì ;0 Lu o^ (' A0NL t/ \/ /\ 2 1f 2" (64mm) BRICK PAVERS, STAMPED CONCRITE SLAB OR CONCRTTE TLES AS SPEC'D FASTEN FOR CONCR POUR r t\ 1x6 (19mmx146mm RIBBôN BOARD POURED CONCRilE FINISH NOSING AS SPËC'D REMOVE FOAM AND - SCREW TRIM INTO FASTENING STRIPS PREP COAT B2OOO ACRYLIC PARGE COAT C/W WET COAT P'OOL LINER COVERING VERTICAL/HORIZONTAL REINFORCEMENT AS PER SHEET 52 NUDURA ONE SIDED TAPERED TOP4" FORM UNIT PalizziPool, 10-6-17 Job: L H39 Aspen Glen Crown Jade Design and Engineering Job No. PLZII-17648 Sheet 54 Nosing Detail POOL DETAIL OF NOSING D*c No. s-4REV. DATE 0 REV. NO. SCAI: 3"=1'-0" DATE ocT 2003 t N¡EçRAI f 0 8{,¡r¿ 0 ttvF t E{H M Q t Q6Y flrrftling V¡lIus, At 1,\ <'r SKIMMER CAP POURED CONCRETE FINISH NOSING AS SPEC'D <-REMOVE FOAM AND SCREW TRIM INTO FASTENING STRIPS SKIMMER PLACED BEFORE POUR OF CONCRFIE HORIZONTAL REINFORCEMENT AS PER SHEET 52 PREP COAT B2OOO ACRYLIC PARGE COAT c,/W }vil- coAT POOL LINER COVERING NUDURA ONE SIDED TAPERED TOP4" FORM UNIT VERTICAL REINFORCEMENT AS PER SHEET 52 1 PalizziPool, 10-6-17 Job: L H39 Aspen Glen Crown Jade Design and Engineering Job No. PLZI1-17648 Sheet S5 Skimmer Detail PooL DErAL or sxtMMen 0 DAIE No. s-5 DATE ocT 2003 ffirEüRÃTEt Fuilû'Nç rEçttMQLOçY Êuiklittg t'r¡fu.l, & Pool, 10-6-17H39 Aspen GlenJade Design and EngineeringJob No. PLZII-17648Sheet 56 Sample photos