Loading...
HomeMy WebLinkAbout1.22 Garfield County Response 12.04.20171644 Platte Street, 4th Floor, Denver, Microgrid Energy December 4, 2017 Garfield County Community Development c/o Patrick Waller 108 8th St, #401 Glenwood Springs, CO 81601 CO 80202 888.734.3033 microgridenergy.com Reference: Major Impact Review for Solar Energy System, Large - 31145 Highway 6 & 24 Silt - Garfield County File Number MIPA - 11-17-8594 Mr. Waller, Please find responses below to your letter dated 12/1/2017 for the above -referenced Major Impact Review. General Application Materials 1. One error was found in the Adjacent Property Owner List. Garfield County Assessor Records show the mailing address for Mike and Michelle Miller (Parcel No. 217905300002) as 208 County Road 227, Rifle, CO 81650. Please update your property owner list with this change. Microgrid Energy Response: Updated list attached. 2. The title commitment and County Records show a Subdivision Exemption in 2008 and again in 2010. Please provide additional information on the history of the property with regards to subdivision exemption. It appears that no plat was ever recorded finalizing the Exemption. If the applicant is no longer pursuing the exemption, the applicant should provide a statement that details they no longer wish to subdivide and the resolution will need to be rescinded. Microgrid Energy Response: Ziegler signed letter recorded with Garfield County 12/21/17. Section 7-107 Compliance 3. To demonstrate compliance with Section 7-107 the application should be updated to provide additional details on the existing driveway. Please update the traffic study to review the existing driveway in comparison to the required traffic standards in Table 7-107. If the driveway does not meet those standards please submit a waiver compliant with Policy 01-14 as attached. Energy Performance Accelerated 1644 Platte Street, 4th Floor, Denver, CO 80202 888.734.3033 Microgrid Energy Microgrid Energy Response: See Enertia Traffic Letter microgridenergy.com 4. The application should be updated to provide more details on the proposed access road, comparing it to County Roadway Standards as detailed in Table 7-107. If the road will not meet County Roadway Standards as detailed in Table 7-107, a Roadway Waiver Request shall be included that demonstrates conformance with the Attached Roadway Waiver Policy. Microgrid Energy Response: See Enertia Traffic Letter 5. Please provide a copy of the referenced CDOT access permit that has been submitted. Microgrid Energy Response: See email from Dan Roussin at CDOT, attached. Section 7-203 Protection of Waterbodies 6. The application indicates that there are wetlands located in the area where the solar development is proposed. The Land Use and Development Code includes wetlands as waterbodies and requires a setback of 35 feet. Please either amend the site plan to show demonstration with this setback or provide a waiver request pursuant to Section 4-118 of the Land use and Development Code. Additional information may be required for this review. Microgrid Energy Response: Applicant formally requests a waiver of this requirement. The wetlands indicated on the site are the result of a breach in an agricultural diversion ditch, and are not the result of a permanent, fully fledged wetland (see report from Western Environment and Ecology submitted with original submittal). Property owner has plans to repair the compromised diversion ditch this winter which will have the effect of redirecting water along the site boundaries, and not through and across the site. Nonetheless, applicant has designed project to limit construction of any structures within the area designated as wetlands to driven -steel foundation posts with negligible cross section in contact with the ground. Therefore, there is no increase in the impervious area of the site, and no fill or dredge activities will occur. The project does not include any grading, and Applicant is working with the United States Army Corps of Engineers (USACE) to obtain a "no permit required" status for the project to proceed as designed. Other information Energy Performance Accelerated 1644 Platte Street, 4th Floor, Denver, CO 80202 888.734.3033 Microgrid Energy microgridenergy.com 7. Please provide a copy of the agreement or another confirmation from Xcel Energy to serve the solar facility. Microgrid Energy Response: See attached Xcel Energy Solar*Rewards Community portal screenshot indicating the project location and status. 8. Please provide contact information for any ditches located on the property Microgrid Energy Response: Cannot find contact info for Lower Cactus Valley Ditch Company. I reached out to Water Colorado but they were unable to return contact info. Ditch is entirely north of and above (elevation) project site. 9. Please update the application so that any Waivers of Standards address Section 4- 118 (C) of the Land Use and Development Code. Any requests for the Waiver of Submission Requirements needs to address Section 4-202 (C). Microgrid Energy Response: Applicant is requesting a Waiver of Submission Requirements 4-203 (F) - Landscape Plan, 4-203 (J) Development Agreement, and 4-203 (K) Improvements Agreement. Applicant believes requests meet the requirements mentioned in Section 4-202 (C). Applicant is requesting a Waiver of Standard 7-203 Protection of Waterbodies. Applicant believes request meets the requirements mentioned in Section 4- 118(C) of the Land Use and Development Code. Please let me know if the above information is satisfactory in response to the issues and concerns you highlighted. Regards, Jon' itzp ck Project Development Manager Microgrid Energy Energy Performance Accelerated