FOUNDATION PLAN
1/4" = 1'-0"
M
co
2301
kr' 1103
Co
N
Co
CV
cY)
Co
J
STRUCTURAL KEYED NOTES
MARK
STRUCTURAL ITEM
1101
CONC. FOOTING - 36" DIA. x 10" (d) SONOTUBE w/ (3) #4's EACH WAY
1102
CONC. FOOTING - 24" DIA. x 10" (d) SONOTUBE w/ (3) #4's EACH WAY
1103
CONC. FOOTING - 18" (w) x 10" (d) x CONT. w/ (2) #4's CONT.
1201
MARRIAGE LINE SUPPORT - RATED STAND (11,000 CAPACITY) OR
DOUBLE -STACKED 8x16 CMU BLOCKS.
1202
MARRIAGE LINE SUPPORT - RATED STAND (4,000 CAPACITY) OR
DOUBLE -STACKED 8x16 CMU BLOCKS.
1203
CHASSIS SUPPORT - RATED STAND (4000 CAPACITY) OR
SINGLE -STACKED 8x16 CMU BLOCKS.
1301
TIE -DOWN - METAL STRAP w/ FRAME CLAMP AND TURN -BUCKLE
1304
FLOOD OPENINGS - 26 OPENINGS. SPACE MORE OR LESS EQUALLY
WITH NO LESS THAN 2 PER WALL. NUMBER MAY BE DECREASED
WITH LARGER OPENINGS. PROVIDE 2030 SQ. IN. MINIMUN NET
OPENING AREA.
2301
FRAMED WALL -TREATED STUD GRADE HEM FIR OR DOUG. FIR -
LARCH 2x4's @ 16" O.C. w/ EXT. GRADE 7/16 PLYWOOD SHEATHING
NAILED WITH 8d COMMON WIRE NAILS SPACED 6"/12" (EDGE/FIELD).
.. I� I IIII-1
liiil� 111,;,1ori 1lll�i±Illlll�rIl1l'
11
FOUNDATION SECTION
1/2" =
niorr---111:1111
,,,111,;,111,;,111-
_III -III � -
'-21/2"
WALL STUD
4***88S
2X4
WIRE MESH STAPLED
TO INTERIOR FACE
OF STUDS AND 2x4's
FLOOD OPENING
1" = 1'-O"
WALL STUD
/7
/
- -
//
//
// �
DESIGN DATA
DESIGN STANDARDS
1. IRC 2012
2. ACI 332-10
3. ANSI/AWC NDS -2012
DESIGN LOADS
1. Roof Live Load = 20 psf
2. Roof Snow Load = 40 psf
3. Basic Wind Speed = 90 mph
4. Seismic
A. Site Class D
B. Seismic Design Category = B
SOIL BEARING CAPACITY
1. Soil Bearing Capacity = 1500 psf
-END OF SECTION -
REINFORCED CONCRETE
PART 1 - GENERAL
1.01 WORK INCLUDED
A. Reinforced concrete structural components as shown in the construction
documents.
1.02 RELATED WORK
Excavation
A. Forming
1.03 QUALITY ASSURANCE
A.
PART 2 - PRODUCTS
Codes and Standards
1. 2012 IRC
2. ACI 332-10
3. ASTM, designations as specified.
2.01 YIATERIALS
A. Concrete: Use concrete having a compressive strength 'f'c' of 2500 psi or
greater.
Reinforcing Steel: Use reinforcing steel having a yield strength 'fy' of 60,000
psi or greater.
PART 3 - EXECJTION
3.01 •ISPECTION
A. Coordinate with mechanical, electrical and architectural prior to pouring
concrete. Provide sleeves, block outs, etc. as required.
0. Verify that adverse soil conditions do not exist prior to pouring foundation
concrete. Inform Engineer of any adverse soil conditions.
3.02 INSTALLATION
Contractor is responsible for proper placement of all embedded anchor
bolts, angles, plates, etc.
Bear all concrete footings at or below frost depth.
6. Bear footings on undisturbed natural material, or on fill that is wetted to 95%
optimum moisture content and compacted in 8" (maximum) loose lifts to 95%
maximum dry density.
D. Wall verts may be wet -stabbed into strip footings.
3.03 PROTECTION
A. Cold Weather Protection.
1. Provide cold weather protection whenever the temperature is
forecast to fall below 40°F within 14 days of concrete placement.
2. Protect concrete against freezing until it has cured for no less than
five days.
3. Do not place concrete in contact with frozen surfaces.
- END OF SECTION-
LUMBEFFRAMING
PART 1 - GENIRAL
1.01 A)RK INCLUDED
A. Lumber -framed structural components as shown in the construction
documents.
1.02 QUALITY ASSURANCE
\. Codes and Standards
1. 2012 IRC
2. ANSI/AWC NDS -2012
PART 2 - PRODJCTS
2.01 MATERIALS
A. Lumber meeting or exceeding the following species and grades:
1. Wall studs and built-up columns Doug -fir Stud Grade
2. Timber Columns Doug -fir No. 2
PART 3 - EXECUTION
3.01 NSTALLATION
1. Lumber in direct contact with foundation concrete must be pressure
treated.
- END OF SECTION -
GENERAL GRADING NOTES
1. SLCoE FINISH GRADE AWAY FORM THE FOUNDATION AT A MINIMUM 2 PERCENT SLOPE
FO A MINIMUM DISTANCE OF 10 FEET MEASURED FROM THE FOUNDATION.
2. FINSHED GRADE AT EXT. FOUNDATION WALL TO BE A MINIMUM 8 INCHES BELOW THE
TO' OF THE FOUNDATION WALL.
3. TOVJF FOUNDATION WALL MUST BE A MINIMUM OF 12 INCHES ABOVE THE DRAI
CUB PLUS 2 PERCENT OF THE DISTANCE FROM THE DRAINAGE CURB TO THE
FqMDATION.
1. PROVIDE CRAWLSPACE VENTS OR CONDITIONING
PER LOCAL CODES.
3D VIEW
(I)
Revision Description
Z
0
(i)w
Rev. Date
4t
V
la)
• aims
co
0
oo
s
4-
L
C�1 i
C os
0
m
O
LO
Co
d'
LO
O�
M
O
Nr
X g
cs •-
lL �
oo
1- -6)
LCA p�
0
0\ U
Mi;r
CL
T‘i
of
0
CD
0
N
0
0
I
w
w
V)