Loading...
HomeMy WebLinkAboutSpecial Inspection Report 07.31.2017WEST SLOPE TESTING & INSPECTION LLC 3177 Glendam Dr Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 8-10-17 Page 1 of 1 Garfield County Building Inspection Dept. 108 8th St., Suite 401 Glenwood Springs, CO 81601 Please find enclosed special inspection report for metal building 416 MJN Rd.. Thank You; Doug Young RECEV e: AUG 1 5 1017 GARF fl i.! J C .: .- )MMUNITY West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Report #1 Page 1 of 1 Date: 7-31-17 Project: Metal Shop Building Address: 416 MJN Rd. Carbondale, CO Building Permit No: BLRE-10-16-4478 Contractor that Performed Work: Tally Ho Construction Inspection of shop fabrication or field work at job site: Field Report: Inspected high strength A325 bolting at the main frame & end wall frame, column & rafter connections. Also randomly tested/verified A325 bolts were adequately tightened. The high strength A325 bolting inspected above appeared to be in substantial conformance with the plans, and the AISC/RCSC Specification for high strength bolting. touglas E. Young C Cer ificatio #5102224 uctu l Wel ing s} s , +�•Inspector/Technician: Douglas E Youngtt l Ste 4 Bo ng �; . al Inspector ray -applied ireproofin l i• pedal Inspector