HomeMy WebLinkAboutOWTS Design Report 07.25.2017v e �* �wmrwrw■a>s>iw� P e ■ a %a Residence : 6809.50' T.O. Ply. (100.-0°) Iso =D *rra+ Walkout DS FF: 6799.50' e 5MIN arnaarrrwwrwrrgawww�rw:rrworr>arwaaaraawaarwwrs�- - , O 3 I -��'i i'D-owe CLEANOUT AT THE BUILDING -4"0 SCH.40 PVC CONSTRUCT A 6" DEEP CUTOFF SWALE ABOVE THE ABSORPTION FIELD CDPHE APPROVED 1,500 -GALLON PRECAST CONCRETE TWO CHAMBER SEPTIC TANK (SEE DETAIL) 4"0 SCHAO PVC OVERFLOW �G\ A / 0 2 /5 Q \ \\ \ \ • 'yiy r MAINTENANCE NOTES INSPECTION \ PORT, TYP. 1. TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE OWTS SYSTEM, THE OWNER SHALL CONSIDER THE FOLLOWING: I.A. MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR SYSTEM WILL WORK. \ I.B. MINIMIZE SOLIDS GOING DOWN THE DRAIN. I.C. ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D. MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. 1.E. USE LINT FILTERS ON LAUNDRY MACHINE DRAINS. \ 1.F. KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER. 1.G. L � 1.H. DO NOT USE LYE -BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN -OFF, OR OTHER STRONG CLEANING AGENTS. 1.1. DO NOT PUT ANY 'ROOT DETERRENTS" DOWN THE DRAIN. 1.J. DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN I.K. MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. 2. THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM. r - SCF r: I /% s' i POTABLE WATER \ �� I i SERVICE SITE EVALUATION SOIL EVALUATION 0 Surveying 12 1. SITE AND SOIL EVALUATIONS WERE PERFORMED BY: 1. SOIL PERCOLATION TESTS IN THE DERICJ. WALTER, PE LOUIS E. ELLER NATIVE SOILS (BASALT GRAVEL, SURFACE Glenwood Springs, CO 81601 BOUNDARIES UNLIMITED INC. HPKUMARGEOTECHNICALENG. COBBLES AND BOULDERS INA fax: 970.384.2833 923000PERAVE, STE. 201 5020C.R.#154 SAND AND SILT MATRIX) RANGED TOPSOIL GLENWOOD SPRINGS, CO 81601 GLENWOOD SPRINGS, CO 81601 FROM 6-10 MPI INDICATING A SOIL 808 IRVING AVENUE BE DONE DURING WET WEATHER AND USE OF 970.945.5252 970.945.7988 TYPE OF 0 AND AN LTAR OF 0.80 BASALT 0 RUBBER TIRE VEHICLES OVER THE ABSORPTION GPD/SF. GRAVEL, 2. EVALUATION DATE(S): JUNE 2017. AREA IS STRICTLY PROHIBITED. COBBLES Know what's below. 2. THE NATIVE SOILS CONTAIN UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD AND 3. SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED BOULDERS. WHEN ENCOUNTERED, BOULDERS V y SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=750 GPD: REMOVED THE BOULDER AND IN A 3.A. SPRING OR WELL=100' BACKFILL THE VOID WITH LOAMY SAND 3.B. POTABLE WATER SUPPLY LINE= 25' SAND OR SANDY GRAVELS. � AND 3.C. POTABLE WATER SUPPLY CISTERN= 25' BEDROCK OR GROUNDWATER IS ENCOUNTERED IN c 3 SILT 3.D. DWELLING=20' COD Lo M THE OVER -EXCAVATION. MATRIX 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 7. (TYPE -O) 3.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' +I 3.G. LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50 (MIN.) n 3.H. DRY GULCH, CUT BANK OR FILL AREA= 25' CONCRETE LID CONCRETE LID 3.1. SEPTIC TANK= 5' FINISH GRADE 3.J. RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): *(TREATMENT LEVEL 1, PRECAST RISER '. GRAVITY FEED) STANDARD INSPECTION PORT, TYP. (4°0 PVC 3. SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): 3.A. SPRING OR WELL=50' 3 c+J Q 3.B. POTABLE WATER SUPPLY LINE=10' N O] 3.C. POTABLE WATER SUPPLY CISTERN=25' CLEANOUT ASSEMBLY, INSTALL A MARKER IF CAP C.4 DDJW 3.D. DWELLING=5' Drafter: BU IS TO BE BURIED. 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' _ 3.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE= 10' IN INFLOW SHALL ENTER THE 3.G. LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND --50' Site & Soils Evaluation 3.11. DRY GULCH, CUT BANK OR FILL AREA= 10' I 3.1. STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5' Scale. N LS ATTACH REMOVABLE CAP OR � w THREADED CLEANOUT ASSEMBLY. U J INSTALL MARKER IF CAP IS TO FINISH GRADE BE BURIED. „ NOTE: 4'0 PVC RISER 4" PVC WYE 4"0 45° BEND 4°0 SEWER LINE oCleanout Scale: N.T.S. 6Al", 1 GRAVELLESS CHAMBER SYSTEM INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS BIODIFFUSER (STANDARD), OR ENGINEER APPROVED EQUAL 1 BOTTOM TO BE LEVEL AND FLAT OVERT ENTIRE AREA TO WITHIN 0.05'±. (TYP.) IF NECESSARY TO ACHIEVE THIS SURFACE, IMPORT CONCRETE SAND TO USE AS LEVELING MATERIAL. REMOVE ANY ENCOUNTERED BOULDERS AND BACKFILL WITH LOAMY SAND OR SANDY GRAVELS. DO NOT USE COMPACTED MATERIALS. GENERAL ABSORPTION AREA NOTES 1. INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2. ABSORPTION TRENCHES SHALL BE 3WIDE OR LESS AND PARALLEL THE GROUND SURFACE CONTOURS. PARALLELING TRENCHES SHALL BE SEPARATED BY A DISTANCE OF 6' MIN. 3. THE BOTTOM OF THE ABSORPTION TRENCHES SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 12" MIN. COVER 24" MAX. COVER INFLOW AND OVERFLOW PIPES SHALL ENTER THE UPPER KNOCKOUTS FINISHED GROUND - MAINTAIN POSITIVE SLOPE AWAY FROM TOP SURFACE OF THE CHAMBER TRENCHES. I I I UNDISTURBED NATIVE SOILS --_J 36" MAX. 4"0 SCH. 40 OR SDR35 PVC OVERFLOW PIPE 6(MIN ) - SERIAL TRENCH SYSTEM Typical Chamber Serial Trench System Scale: N.T.S. Vicinity Map Carbondale _ To Basalt V=4000' SYSTEM NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH PITKIN COUNTY REGULATION 6.28 ONSITE WASTEWATER TREATMENT SYSTEMS (OWTS), MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS, THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE ENGINEER MUST OBSERVE THE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE A LETTER OF INSPECTION AS REQUIRED BY THE LOCAL AGENCY. A REQUEST FOR INSPECTION MUST BE MADE BY THE CONTRACTOR AT LEAST 48 -HOURS PRIOR TO THE EXPECTED TIME OF BACKFILLING. 2. DEMAND CALCULATIONS (SEC.43.6.A.2.h) 2.A. FOUR (4) BEDROOM RESIDENCE USING DOSING AND TREATMENT LEVEL 1 (TL1). 2.8. AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BODS): 2.8.1. SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BODS lbs/day 2.8.2. ADWF = 75 gpd' (3 BEDROOMS ` 2 PERSONS/BEDROOM + 1 BUNK ROOM' 4 PERSONS) =750 gpd 2.B.3. BODS = 0.20 lbs/day ` (3 BEDROOMS ` 2 PERSONS/BEDROOM + 1 BUNK ROOM' 4 PERSONS) = 2.00lbs/day BODS ml = BOD5'1,000,000 = 2.00lbs/day`1,000,000 = 319.8 mg/L ADWF`8.34 750gpd`6.34 2.B.4. CBOD5 = BODS " 0.85 = 272 mg7L 3. SEPTIC TANK (SEC.43.9.B.2.2): 3.A. SEPTIC TANK: 10 PERSONS EQUATES TO 5 BEDROOMS @ 2 PERSONS/BEDROOM. THEREFORE, 1,250 GALLONS + 250 GALLONS = 1,500 GALLONS 3.B. INSTALL A 1,500 -GALLON TWO-COMPARTMENT TANK. 3.C. THE TANK IS NOT SUBJECT TO BUOYANCY. 4. ABSORPTION AREA CALCULATIONS 4.A. GROUNDWATER WAS NOT ENCOUNTERED, THE PROPERTY CONTAINS SLOPES LESS THAN 20%, BUT THE SOILS CONTAIN AND LARGE QUANTITY OF BOULDERS. THEREFORE, THE SYSTEM SHALL BE A PRESSURE DOSED SHALLOW GRAVELLESS CHAMBER SYSTEM IN A SEQUENCED TRENCH CONFIGURATION. 4.B. SOILS WERE ANALYZED BY He KUMAR GEOTECHNICAL ENGINEERING (JUNE 21, 2017; PROJECT NO.17-7-349) TO BASALT GRAVEL, COBBLES AND BOULDERS IN A SAND AND SILT MATRIX (TYPE -0) WITH A TREATMENT LEVEL 1 LONG TERM ACCEPTANCE RATE (LTAR) OF 0.80 gpd/SF. 4.C. MINIMUM SOIL TREATMENT AREA, A: A= ADWF = 750 = 938 S.F. LTAR 0.80gpd/S.F. 4.D. SIZE ADJUSTMENT FACTORS: GRAVITY TRENCH = 1.0; CHAMBER TRENCH= 0.7 4.D.1. A, adj = 938 SF , 1.0' 0.7 = 567 SF 4.E. GRAVELLESS CHAMBER SYSTEM: 4.E.1. INFILTRATOR QUICK4: 567 SF / 12 SF/UNIT = 55 UNITS IN TRENCH CONFIGURATION. 4.E.2. ADS BIODIFFUSER (STANDARD): 657 SF / 18.75 SF/ UNIT = 36 UNITS IN A TRENCH CONFIGURATION. 5. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITES OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 6. CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS AND AT LEAST EVERY 100 -FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9. INSTALL 3 -INCHES OF BLUEBOARD INSULATION, 3 -FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 5 -FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2 -FEET. 10. SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 4. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE 0 Surveying m & Beyond AND AROUND THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING 923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 ABSORPTION AREA. fax: 970.384.2833 Engineer or Surveyor Seal 5. NO EXCAVATION OF THE ABSORPTION FIELD IS TO KEVIN STROM 808 IRVING AVENUE BE DONE DURING WET WEATHER AND USE OF 630.567.40402 NORTH 0 RUBBER TIRE VEHICLES OVER THE ABSORPTION Scale 1 10' AREA IS STRICTLY PROHIBITED. Know what's below. 6. UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL V y CONSIST OF IMPORTED LOAMY SAND OR SANDY G] GRAVEL. THE ENGINEER SHALL BE CONTACTED IF Q � L i BEDROCK OR GROUNDWATER IS ENCOUNTERED IN c 3 V a? COD Lo M THE OVER -EXCAVATION. '111►r 7. TOPSOIL COVER MAY BE VARIED (1 -FOOT MINIMUM, J .y 6'TOPSOIL 2 -FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING. (MIN.) CONCRETE LID CONCRETE LID 0 N FINISH GRADE PRECAST RISER '. STANDARD INSPECTION PORT, TYP. (4°0 PVC SOLID PIPE CUT TO FIT. LOCATE PER PLAN VIEW. T 3 c+J Q YJ ATTACH REMOVABLE CAP OR THREADED N O] PROJECT NO. 17013 Sheet CLEANOUT ASSEMBLY, INSTALL A MARKER IF CAP C.4 DDJW Drafter: BU IS TO BE BURIED. Date: 07/25/17 _ IN INFLOW SHALL ENTER THE _ PVC COUPLING FOR SUPPORT w LARGER CHAMBER I J w � U m i � w U J � „ NOTE: STATE APPROVED 1500 -GALLON TWO (2) CHAMBER CONCRETE BAFFLE OPENING SEPTIC TANK. j JI 1' CRUSHED ROCK. 6" DEEP TO LEVEL TANK Septic Tank & Dosing System Seale: N.T.S. Civil Engineering 0 Surveying m & Beyond 0 d Inc 923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 tele: 970.945.5252 fax: 970.384.2833 Engineer or Surveyor Seal Client Information: KEVIN STROM 808 IRVING AVENUE WHEATON, IL 60187 630.567.40402 NORTH 0 10' 20' Scale 1 10' Know what's below. Call before you dig. V y G] Q � L i c 3 V a? COD Lo M '111►r Q ai J .y T m 0 N 0 z T N c+J Q YJ FO N O] PROJECT NO. 17013 Sheet FILE NAME: 17013-c-topo.dwg ner: C.4 DDJW Drafter: BU Date: 07/25/17