HomeMy WebLinkAboutApplicationGarfield County
BUILDING PERMIT
APPLICATION
lvlAR 2 0 2018
BÏ:
R.EC T ity Development Department
8th Street, Suite 401
Springs, CO 81601
le7ol94s-82L2
TYPE OF COT{STßUCT
fl Commercíal/Multi-FamilY E Demolition
Manufactured Home or
lÏl Residentíal (SF, DuplexorTownhome)Reroof
INN'OLVED'P'ARTIES
Propefi Owner:
Mailing Address:
Alan and Kathleen Rand Phone:{(914)ì443-0989
43 Buttermilk Falls Rd Warwick NY 10990
Email Address:arandôl 448@optonli ne. net
Contractor!Cleary Building Corp Phone:f (e70) p71-1066
Malllng Addressr 7158 Highway 50 North, Delta, CO 81401
EmailAddress:lgun n@clearybuilding.com
Architect: phone:(
Mailing Addressr ,
EmailAddress:
Englneer: Phone:tt
Malling Address:
EmallAddress: -
Manufactured tlome lnstaller: Phone:t)
MailingAddress;
EmailAddre¡s: .
Describe Work:Barn
Job Address:1215 N Cedar Springs Ranch Rd Rifle, CO 81650
Assessorrs Parcel Number:2403A2400070
Sub.Cedar Springs Ranch tot 2 Block
-
Owne/s Valuation of Work:Property Size (Sq. Ft. or Acres):35 p6.r¿ ç
Sq. Ft. of Building:2352 Height:16'gu /l
# of Floors;-!-
Class of Work:fl ruew ! Alteration ll ¡duition ! nepair ll Move/Relocation
Garage:Inttached l_lDetached
PROJECÍ DETAI$ CONïNUET'
Sêpt¡c:tr OWTS I Community
Type of Heat:l_lNatural Gas I tropane l_l Electric I lottrer
Driveway Permit:l-l Exempt I lPermit f:
NOTICE
Authoritv. This application for a Building Permit must be signed by the Owner of the property, descríbed above,
or an authorized agent. lf the signature below is not that of the Owner, a separate letter of authority, signed by
the Owner, must be províded with this Applícation.
Legal Access. A Building Permit cannot be issued without proof of legal and adequate access to the property for
purposes of inspections by the Building Division.
Other Permits. Multíple separate permits may be required: (1) State Electrical Permit, (2) County OWTS Permit,
(3) another permit required for use on the property identified above, e.g. State or County Highway/ Road Access
or a State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days
of the date of íssuance and if work is suspended or abandoned for a period of 180 days after commencement.
CERTIFICATION
I hereby certify that I have read this Application and that the information contained above is true and correct. I
understand that the Building Dívision accepts the Application, along with the plans and specificatíons and other
data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming
completeness of the submittals and approval of thís Application, a Building Permit will be issued granting
permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by
the Building Division. ln consideration of the issuance of the Building Permit, I agree that I and my agents will
comply with provisions of any federal, state or local law regulating the work and the Garfield County Building
Code, OWTS regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the
Building Permit may be suspended or revoked, upon notice from the County, if the locatíon, construction or use
of the structure{s) and facilitv(ies), descríbed above, are not in compliance with County Regulation(s) or any
other applicable law.
I hereby grant permission to the Buildíng Division to enter the property, descríbed above, to inspect the work. I
further acknowledge that the issuance of the Buílding Permit does not prevent the Building Official from: (1)
requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping
construction or use of the structure(s) or facility(ies) if such is in violation of County Regulatíon(s) or any other
applicable law. Review of this Application, including submittals, and inspections of the work by the Building
Division do not constitute an acceptance of responsibility or liability by the County of errors, omissions or
díscrepancies. As the Owner, I acknowledge that responsibility for compliance with federal, state and local laws
and County Regulations rest with me and my authorized agents, including without limÍtation my architect
designer, engineer and/ or builder
I hereby acknowledge that I have read and understand the Notice and Certification above, as well as, have
provided required which is correct and accurate to the best of my knowledge.
2-)IS IK
Property Owner Print and Sign
l4t o^ R-*^d
Date
oFFrcrArusEoNly fàiô ßlaolt g \/¿ù(dLol ó¿e,95.? I
soe'ffi!"ffi1oùrr9- lief ú{ Mifionç.
Adiusted Valuation:+it},4t7.ö0 Plan Check Fee:
+ û6b.46
Permit Fee:øl'ôrf"%Manu home Fee:
L\/Â
Misc Fees:
Total Fdes:*\fl+t.7?Fees Paid:
$roß5.g8 Balance Due:+how.ry BP Nolffir -ÕtAô
OWTS No:
,9= lo
OCC Group:u ConstType: V_V þnins:
,
414(ØbBUITDING / PTANNING DIVISION :
Signed Approval Date
tsuildine/ Zpnins Plan Review Checklist
Ø,fr-æ-tb->tæ
Raç'A buvn
Perrnit umber:
Buil ns
Engineered Foundation
/ Driveway Permit
/ Surveyed Site Plan
Plannine/ Tonins
'/ property Line Setbacks
x/a
Septic Permit and Setbacks
'/ Grade/ Topo graphy 3o%
Attach Residentíal PIan Review List
/ Subdivisíon Plat Notes
Fire Department Revíew
Valuation Determinatíon/ Fees
Red Line Plans/ Stamps/ Sticker
Attach Condítions
,/
Application Signed
'/ Plan Reviewer to Sign Applícatíon
'/ Parcel/schedule No.
N/A 40# Showload Letter- Manu. HomesxSoils Report
30 ft. Stream Setbacks
N Flood Plain
./ Buitding Height
N/,
Zoning Sign-Off
Road lmpact Fees
Grade/ Topography 40%
Planníng lssues
'/ subdivísÍon plat
General Comments:
Cutual fu."ttn 4?rc
\?abØ,w W ç1A¿à9
Wal ab4Þ
\t^h^ô,ltoVt -
Ea4>xa24.44=4ltqøtv'
ñ/,
NÁ
løupnq /lAsL'- I^
TVW o( covevuah'on'" V-Þ
@ l^W,rÅ F"t+, N/A
(po ftahlabtL A/a)
and/or plans for compliance, the application may be placed on hold untilthe required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Reviewfee at time of application submittal. The permit fee, as
well as any Road lmpact fees will þe collected when the permit is issued.
The permit application must be signed by the owner or by person having written authority from the owner
to ast as their representative.
Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a
CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO
inspection requirements will be attached to your approved field set of plans.)
I hereby acknowledge I have read, underctand and will abide by the requirements of this
checkllst,
slrslrt
Property Owner and Date
A\o,- T(o^å
Gørfteld County
:lr, .::Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
l970l94s-82t2
wwtl¿.sa rf i e I d-c o u n tv. com
SINGLE FAMILY OR DUPLEX BUILDING PERMIT APPLICATION CHECKLIST
ln order to understand the scope of work intended and to expedite the issuance of a permit, it is
important that complete information be provided. Please review this document to determine if you have
adequate information to design your project and to facilitate a plan review.
APPLICATION FORM: Please make sure the following information is provided on the application.
. Parcel number obtained from the County Assessol's Office.
¡ Job address (assigned physical address). Legal Description: block, lot, tract, subdivision, filing, or section, township and range.
. Owner's name, mailing address, phone, fax or cell.
. Contactors name, mailing address, phone, fax, or cell.
. Architect and/or Engineeds name, mailing address, phOne, fax or cell.
. Building size, height, number of stories and lot size.
. Use of building (Residential).. Class of Work (New, Addition, Alteration, Repair, Ðemo, Move/ Relocation).
. Detailed description of work.. Type of heating (natural gas, propane, electric, other).
. Sewer system (Community or OWTS), also see other items below.
. Garage (Attached or Detached).. Driveway permit (please see other items below).
. Valuation (labor and materials), see attached worksheet'
OTHER ITEMS:. lf you anticipate obtaining a water-tap from the City of Rifle, please provide a letter indicating that
the City will provide water service. Required to submit building permit application.
¡ OWTS requires a septic permit application to be submitted with the building permit application.
. A separate electrical permit must þe oþtained from the State of Colorado Electrical Board.
r At the time of building permit submittal, you are required to show proof of legal and adequate
access to the site. This may include proof of right to use a private easement, County Road &
Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The
County Road & Bridge Ðepartment can be reached at 970-625-8601.
r lf you anticipate excavating or grading prior to issuance of a þuilding permit, you will be required
to obtain a separate grading permit.
. lf you belong to a Homeowìers Association (HOA) it is your responsibility to obtain written
approval, if required.. Provide copies of any Resolutions and/or Land Use Permits associated with this property.
. Additional Dwelling Units may require Administrative Review'
. Minimum dwelling dimension is 20 ft. wide x 20 ft. long.
. A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups,
unless the homeowner is performing the work.
BUILDING PLANS: 2 sets of plans must þe submitted. Plans must þe 18"x24" minimum size, complete,
identical, legible and to scale. All plans will be checked at the counter for completeness. lf any of the
required information is missing, the building permit application cannot be accepted.
SITE PLAN: Please make sure the following information is provided on the site plan.
. Property address/legal description.¡ North Arrow and Scale on each page.
. Show all property lines, þuilding envelopes, flood plain and easements.
r Provide setback distances from boundaries, þuildings, septic, well and waterways.
¡ Location and direction of the county or private road and driveway accessing the property.
r Proposed and existing structures. lnclude sheds, barns, decks, patios, and any other buildings.
o Existing and proposed grade, positive drainage around structure (to be contained on site).
. Streams, rivers, creeks, springs, ponds and ditches,e Existing and proposed wells, septic tanks, leach fields and other systems (if applicable).
r Retaining walls (engineer stamped detail required for walls over 4 ft., measured from bottom of
footing to top of wall).
NOTE: Any site plan depicting the placement of any portion of the structure within 50 feet of a property
line or not within an established building envelope shall be prepared, stamped and signed by a licensed
surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision
final plat with the proposed structure located in the building envelope.
ARCHITECTURAL PLANS: Please provide the following information on the architectural plans.
. Minimum of four (4) elevations (N,S,E,W). lndicate height of building measured from existing
grade to the midpoint between the ridge and eave of a gable or shed roof or to the top of a flat
roof.r Floor plans for each level, including dimensions and scale noted.. Clearly label each room or space (bedroom, bath, kitchen, closet, etc).. Show the location of the mechanical equipment.. Building cross sec{ions with construction details.¡ Window sizes, types and operation noted on the floor plans or elevations.
. Specify roof slope/pitch, roof covering and siding materials.. Stair and guard details specifying rise, run, height and spacing.
o Attic, roof and crawlspace ventilation details. lndicate size and location of ventilation openings.
o Minimum insulation shown for walls, floors, roofs/ceilings, slabs, basements and crawlspaces.
r Provide stove and fireplace make, model, EPA or Colorado Phase ll Certificat¡on. Masonry
fireplaces shall be designed to the lnternational Residential Code (lRC) requirements.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
. Design specifications to include roof and deck snow load, wind and seismic design and frost
depth.. Foundation plan showing complete footing and foundation dimensions.
r Footing and foundation details specifying reinforcement and referenced on plans.
r Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses
specified. Pre-manufactured structures require the engineers stamp, signature and date.
. Framing /connection details, braced wall lines, shear wall schedule, location and hold downs.
NOTE: lf any required information is missing, delays in issuing the permit are to be expected. lf
determined by the Buildlng Official that additional information is necessary to review the application