HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-03-18-5158 and SEPT -03-18-5159
David & Kara Herrala
New Single -Family Residence
TBD County Road 214, New Castle
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (IRC)
AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC).
2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY BUILDING REQUIREMENTS.
REDLINED NUMERIC NOTATIONS ON PLANS REFER TO ANNOTATED ITEMS ON THE
ATTACHED "RESIDENTIAL PLAN REVIEW LIST".
3) PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY, OWNER SHALL
PROVIDE COPY OF ACCESS EASEMENT ACROSS ADJOINING PROPERTY LOCATED AT 5991
COUNTY ROAD 214, WHICH IS REQUIRED TO PROVIDE LEGAL ACCESS TO THE SUBJECT
PARCEL OF LAND. PROVIDE DOCUMENTATION THAT THIS ACCESS EASEMENT HAS BEEN
RECORDED AT GARFIELD COUNTY CLERK & RECORDER'S OFFICE.
4) INSTALLATION OF STRAIGHT -SHAFT DRILLED PIER FOUNDATION SYSTEM TO FOLLOW
RECOMMENDATIONS CONTAINED IN GEOTECHNICAL REPORT PREPARED BY HP-KUMAR.
SOILS ENGINEER OF RECORD TO BE PRESENT AT JOB SITE DURING PIER DRILLING TO
VERIFY THAT BEARING STRATA HAS BEEN REACHED AND MINIMUM REQUIREMENTS
CONTAINED IN REPORT HAVE BEEN MET. PROVIDE GEOTECHNICAL ENGINEER'S SEALED
APPROVAL REPORT FOR CONCRETE PIER FOOTINGS AT FOUNDATION INSPECTION.
5) A SEPARATE LOCK -OFF OR ACCESSORY DWELLING UNIT IS SPECIFICALLY NOT AN
APPROVED USE UNDER THIS BUILDING PERMIT, AND ANY SUCH FUTURE USE WILL FIRST
REQUIRE A LAND -USE CHANGE PERMIT UNDER PROVISIONS OF GARFIELD COUNTY'S
LAND USE AND DEVELOPMENT CODE.
6) SEPTIC SYSTEM DESIGN AND INSTALLATION SHALL COMPLY WITH GARFIELD COUNTY'S
ON-SITE WASTEWATER TREATMENT SYSTEM (O.W.T.S.) REQUIREMENTS INCLUDING
APPLICABLE SETBACKS.
7) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD.
ELECTRICAL ROUGH -IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.