HomeMy WebLinkAboutInterior Lighting Compliance CertificateCOMchecR Software Version 4.1.0.0
lnterior Lighting Gompliance
Certificate
Section 1: Project lnformation
Energy Gode; 2009 IECC
Project Title: Anytime Fitness
PrCI¡ecf Tlpe: Alteration
Construction Site:
7025 Highway 82
Glenwood Springs, CO 81601
Owner/Agenl:
Anylime Fítness
Glenwood Springs, CO
Designer/Contractor:
Jay Rohkohl
Dunham Associates
50 South Sixlh Street
Suite I l0O
Minneaplls. MN 55404
{Gr2}46s-7550
Section 2: lnterior Lighting and Power Calculation
A
Area Gategory
B
Floor Area
tflzÌ
c
Allowed
Wattú /frz
D
AllowedWatte
(BrC)
Fibress Center lExercise Cer¡ter)6589 1 6589
Total Allowed Watts = 6589
Section 3: lnterior Lighting Fixture Schedule
A
Flxture lD : Descrlptlon / Lamp / Wattage Per Lamp / Ballast
BCDE
Lamps/ # of Flxture (C X D)
Flxture Flxturcs ìlVatt
Fitness Genter ( Exercise Center 6589 sq.ft.)
Track lighting 'l: D: TRAGK HEAD: Vtlattage bassd m tolal luninaircs
LED 1: A:zXZ RECESSED: Other:
LED 2: B/BE: 8' lndustrial Chain Hung: Other:
LED 3: B1lB1E: 4' lndustrial Chain Hung: Other:
LED 4: F: 1x4 Surface Strip: Other:
LED 5: FI: 1x4 Strip: Other:
LED 6: c: DOWNLIGHT; Other:
0
1
1
1
1
1
1
200
35
88
44
48
33
9.5
0
28
27
5
t
3
2
N
s80
2376
220
288
99
f9
Total Proposed Watts = 4182
Section 4: Requirements Ghecklist
lnterior Lighting PASSES
Lighting Wattage:
& 1. Total proposed watts must be less than or equal to total allowed waüs.
Allowed Watts Proposed Watts Gomplles
6589 4182 Passes
Gontrols, $$tching, and Wiring:
N/A ü 2. Daylightzones under skylights more than T5 feet from lhe perimeter have lighting controfs separate from daylíght zones adjacent to
vertical fenestralion.
& 3. Dayl¡ght zones have individual lighting controls independent from that of the general area lightíng.
Exceptìons:
fl Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device.
Project Title: Anytime Fitness Report date: 0g/g0/1gData filename: P:\201 9\0419740-023-00 ATF - Glenwood Springs, Co\03-Electrical\23-ATF_Gleenwood Springs Co.cck page .l of 2
N1A
N/A
N/A
&4.
Ds.
Q6.
o7.
&8.
lhe 2009 I
Ghecklist.
[f Daylight spaces enclosed by walls or ceiling height parlilions and conla¡n¡ng lwo or fewer light fixtures are not required to have aseparate switch lor general area lighting.
lndependent controls for each space (switcù/occupancy sensor).
Exceptions:
Q Areas designated as secur¡ty or emergency areas that must be continuously illuminated.
ü Llghtlng ln stâirways or coridor.s that are elements ol the means ol egress.
Masler swikh at enûy to tlstdfrnotel gue$t r(xm-
lndividual dwelling units separately metered.
Medical task lighting or arVhislory display lighting claimed to be exempt from compliance has a control device independent of the control
of the nonexempt lighting.
Each space required to have a manual control also allows for reducing the connecled lighting load by at least 50 percent by eithercontrolling all luminaires, dual switching of allernate rows of luminaires, alternale luminaires, or alteinate lamps, swilchingihe middlelamp luminaires independently of other lamps, or switch¡ng each luminaire or each lamp.
Exceptions:
D Only one luminaire ¡n space.
f] An occupant-sensing device controls the area.
I The area is a corridor, storeroom, restroom, public lobby or sleeping unit.
I Areas that use leÊs than O-6 Watts/q,lt.
N/A n 9. Automatic lighting shutolf controt in buitdings targer rhan s,000 sq.fr. BUildíng lS 24/T OpefAtion.
Exceptions:
Q Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security.p l0.Photocell/astronomical lime switch on exterior lights.
Exceptions:
I Lighting intended for 24 hour use.
N/A D 1't .Tandem wired onelamp and three-lamp ballasted luminaires (No singlelamp ballasts).
Exceptions:
I Electronic high{requency ballasts; Luminaires on emergency circuits or with no available pair.
Section 5: Gompliance Statement
Compliance Statement: The proposed lighting alteration project represented in this document is cons¡slent with the building plans,
specifications and other calculations submitted with this permil applicalion. The proposed lighting alteration project has been designed to meet
ECC, chapter 8, requiremenls in coMcåeckVersion 4.1.0.0 and to comply with the mandatory requirements in the Requirements
Jay Flohkohl 08/30/2018
Name - Title Date
Project Title: Anytime Fitness
Data filename: P-t2019\0419740-023-00 ATF - Glenwood Springs, CO\03-Electrical\23-ATF-Gteenwood Spdnæ *.*,1*p* *Ë"f;i;:
¡