HomeMy WebLinkAboutOWTS Installation Obeservations Report 07.07.2018&tt
ffrfrwåtä
33 Four Wheel Drive Rd
Csrbondqle, C0 8ló2¡
970-309-5259
July 7,2018 Project No. C1379
Travis Stanley
lnteg rated Elements Construction
Tstan34_1@gmail.çsm
On site Wastewater Treatment System (OWTS ) I nstal lation Observations
1000 cR 323
Garfield County, Colorado
Permit N umber SEPT-04-1 B -5225
Travis,
ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS)
on June 14,2018 for the subject property. lntegrated Elements Construction installed the system.
The sewer line exiting the residence and the 1OOO-gallon, two-compartment Forterra concrete septic tank
have already been installed prior to our involvement with this design. An effluent filter was installed on
the outlet tee of the septic tank. This filter must be cleaned annually, or as needed. Risers were
installed to bring the manhole lids to grade for access.
Effluent gravity flows to a level manifold connecting four rows of 14 'Quick 4' Standard Plus lnfiltrator@
chambers for a total of 56 chambers and 672 square feet of infiltrative area. The infiltrative area was
installed in the silt loam horizon, below the clay horizon. lnspection ports were installed in the four
corners of the bed. Ports may be cut to grade and placed in sprinkler boxes for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship andior parts and materials. ALL SERVICE septic, LLC should be notified if changes are
made to the OWTS in the future. Any additional OWTS construction must be according to the county
regulations.
LIMITS:
Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By
(ø"t,t,x Cs*øu"g
98662
Carla Ostberg, MPH, REHS
Richard H.
Chamber bed
Cleanouts
level manifold
tt rltt.,
':r
lnlet tee
Chamber bed
Effluent filter Sewer line existing the septic tank
it'¡o Sewer line leading to STA
I
View of STA
il.t8ililff33 Four Wheel Drive R€dÐarbondale, Colorado 81623Phone 970.309-5259ærla@allserv¡Gept¡c.æmAw0' 5' 10.Sæle: 1" = 10'-O'NEW'QUICK.4' CHAMBER BED.4 ROWS OF 14 CHAMBERS =56 GHAMBERS = 672 SFINSPECTION PORT AT EACHCORNER OF STAl0'TONOTE: EXISTINGSYSTEMPROPERTY ABANDONEDLINE4' DIA SDR-35 SEWER LINEADDITIONt_NEW lOOO-GALLON,TWO-COMPARTMENT FORTERRACONCRETE SEPTIC TANK ALREADYINSTALLED. EFFLIJENT FILTERINSTALLEDMINIMUM 'IO'FROMPOWER POLE TOELECIRICAL LINEFROM STANEW 4' DIA SDR-35 SEWER LINEWITH DOUBLE-SWEEP CLEANOUT1-BEDROOMADDITION TORESIDENCEo¿\r\.'%,¿ìEXISTING2-BEDROOMRESIDENCE2\tafl6¿'v"'IJ!t)McDaniel Residence1000 cR 323Garf¡eld County, Cdo€doPnject Number: C1379recordDatet o7to7h8 Ioes¡qneo eç ceolReviewed By: RHPIDËwn Bv: ANM ISheet 1 of 1