HomeMy WebLinkAboutSoil Investigation 07.13.2018CÍVCO Engine ering, Inc. CivÍl Engineering Consultonts P.O. Box t758 3ó5 West 50 North, Suite W-l Vernol, Utoh 84078 July 13, 2018 Brian Quintana Clayton Homes 671 23 Road Grand Junction, CO 81505 Dear Brian, Subiect SoiI lnvestigation - $cott Residence in Parachute, Gotorado I am writing thís letter to report the tindings of a soil investigation that was conducted at the proposed sile for the Scott residence in Parachute, Colorado. The investigation entailed the analysis of one soil sample that was taken from the construction site at approximately the location and bearing depth of the proposed foundation. Testing of the soil sample included a sieve analysis and Atterberg Limits testing. The test results were used to classify lhe soil sample as 'OH' according to the Unified Soil Classification System. Copies of the soil data are included with this letter. OH soils include organic clays of medium to high plast¡c¡ty and organic silts. Literature suggests that OH soils are likely to have relatively low bearing capacity. I recommend a soil bgaring capacity of 1500 psf be used for foundation design. Over the years, a number of studies have been conducted in an effort to correlate soil shrink-swell potential to atterberg limit data. According to one study, liquid limits less than 50% and plasticity indexes less than 25o/o, generally suggest a soil will have a low shrinklswell potential. Using the conclusions of that study, the atterberg test results for this soil sample suggest that the soil has a low potential for expansion. The liquid limit for the soil was found to be 31% which is within the low- expansion limit, and the plasticity index for the soil was found to be 13% which is also within the low- expansion limit. Please note that Atterberg limits tests do not address soil mineralogy and thus may be limited in their ability to reliably predict soil shrink-swell potential. ln addition to soil expansion, frost heave of the foundation is also a possibílity. Therefore it is important that structural foundations bear below the local frost penetration depth or be frost-protected with insulation. Frost heave results from soil moisture expanding as il freezes. Therefore, every effort should be taken to límit soil moisture in the vicinity of foundations. Walkways, driveways, and ground surfaces should be graded to flow away from the foundation. Gutter down-spout outlets should discharge at least five feet away from the foundation. Vegetation requiring significant watering should not be planled near the foundation, No testing was done to determine the soil's collapse potential. ln my experience, foundation failures due to soil collapse are generally even more catastrophic than failures due to soil expansion. ln every instance of soil collapse failure that I have investigated, the damaged home was located at the mouth of a pronounced drainage, such as a canyon or gully where the soil has been deposited alluvially by intermittent runoff water flows. Alluviallydeposited soils are typically not very dense and derive their strength from mineraf bonds that form between soil particles. When these soils become wet, the mineral bonds dissolve, allowing the soil particles to consolidate (collapse) under any load that is in excess of that which existed when the mineral bonds originally formed. Phone (435[89-?448 * Fax (435F89-4485 Emoíl : vqncekíng@civcoengineeríng. com . Page2 July 13, 2018 Verify that the project site is not at the mouth of any obvious draínage. The aforementioned methods for lowering the risk of frost heave are also key to lessening the risk of soil collapse failure. ln summary, the soil under the foundalion was not specifically tested to determine expansiveness but was found to have a liquid limit and a plasticity index that suggest the soil to have a low potential for expansion. Likewise the soil was not specifically tested to determine bearing capacity but was found to be of a type having lower characteristic bearing capacities. For design purposes, a maximum 1500 psf bearing capacity is recommended. The home owner should make every effort to keep moisture from being introduced to the soil near the foundation. Any future purchaser of the home should be apprised of the underlying soil characteristics and the importance of keeping moisture away from the foundation. This concludes my report. Please note that this investigation was performed for the purpose of providing general information regarding the soil underl$ng the proposed home and makes no prediction of foundational performance. ïhis report should not be regarded as documentation of a geotechnical investigation as I am not a geotechnical engineer. Please contact me if you have questions regarding this report. Sincerely, Vance V. King, PE Engineer CIVCO Engineering, lnc. Enclosure Cc:Project File Gt. C. Testin-g' fn" zsi+ South 1500 East üÉn¡.ñ1, UTAH 84078 ilñ tnbs¡7le-a220 Fax $dQ 781-1876 stE k) Pr{ect No. or Clienl: MalaialfYPe: D¡sþncðffit Cl: VE ANALYSIS Depth: Tested By RG LIMITS l Stãtions: Date SamPled:Date Tested MF= ?ftlr+L'TLL pú1t I 37 It{ße-g- TtsT A S,HTO 1'27 Coarse Gradation SpecsSize Total % Rel.Ret.3'T ¡r*m¡2'2'1.5'1.5' 1"'l'a2sÍrn¡ 314'314' 112'112'ltz-*rnl 3/B'3/8' f4 çt,rsrm¡ *4 t¡,zs¡t¡n) WT ORYWT ta,75rrm) Totãl LrmtlAASHTO T.89 8 T.9O Llrril L¡rril Ptåstic ¡ndêi( CÞssllicãÞoñ d4 Morsture Data wt. wt. H20 wr. HzA% Washed Wr Firæ Sier¡e Size Welght Ret.% Rel.% Pass #4 {¡.rs¡rrn} lf8 {e.¡onm}L-¿')rì #10 ¡eonn¡rì n2 c lt.v #16 (t.18rrn) #20 {ð$Fß)f7 #30 (ooop) #40 {4?5|lr}o,Y x.x #50 Goo,tn) #60 {250¡n:) 1rænn)^.1A 00 (r50pn) .I {Ll.' #200 {?âm)I n{5f .¡{{o- t +200 m .-ì(t;J.t Total Rernarks Dave Argo From: Sent: To: Cc: Subject: Attachments: Quintana, Brian < Brian.Quintana@ClaytonHomes.com > Wednesday, August 22, 2018 9:42 AM Dave Argo Brooke Winschell MCcarty Soils 1-80713 soil rpt - brian.pdf Attached is the soils report from the engineer for 3000 county Rd 301 in Parachute I am currently working on a better plot plan to scale showing the whole property and set backs. Thanks Brian Quintanø Home Consultant Clayton Homes Home Center 1037 O: 970.245.9039 C:97O.4O4.7065 From: Va nce <va nceking@civcoengineering.com> Sent: Tuesday, August 2L,2OI8 9:08 AM To: Ruse, Shawn Cc: Quintana, Brian Subject: RE: IEXTERNAL] RE: Scott in Rulison Here are scans of what is on its way to you in the mail. You will receive: Wet-stamped prints (4 copies) Wet-stamped soil report (1 coPy) lnvoice (L copy) Thanks, Vance King, CTVCO Engineering, Inc PO Box 1758 Vernal, UT 84078 435-789-5448 From: Ruse, Shawn Imailto:Shawn.Ruse@ClaytonHomes'com] Sent: Friday, August 77, 20IB 4:14 PM To: Vance Cc: Quintana, Brian Subject: Re: IEXTERNAL] RE: Scott in Rulison Looks good Thank You Shawn Ruse 1