HomeMy WebLinkAboutState Rough-In Electrical Inspection Report 05.30.2018Jim Wilson
From: Robert Parrington <robert.parrington@yahoo.com>
Sent: Thursday, May 31, 2018 1:58 PM
To: Jim Wilson
Subject: Fwd: Inspection Report for Permit: 837872
Dora for 631 Gage rd rough in
Sent from my iPhone
Begin forwarded message:
From: Clint Hostettler <elint@walker-electric.biz7
Date: May 31, 2018 at 1:51:42 PM MDT
To: "rohert.parrington@yahoo.com" <robert.parrington yahoo.com>
Subject: FW: Inspection Report for Permit: 837872
Clint Hostettler
lyjg
TVar.kcr Electric, Inc.
PC Box 867
Rifle, CO 81650
970.625-5192 o
970.625-1977 f
From: dors electricaiboard@state.co.us [maiito:dora electrica#board@state.co.us]
Sent: Thursday, May 31, 2018 12:00 AM
To: Admin
Subject: Inspection Report for Permit: 837872
COLORADO STATE ELECTRICAL BOARD
1560 Broadway, Suite 1350
Denver, Colorado 80202
Automatic email - Do not reply to this email.
1
Inspection Report
Permit #: 837872 Date Inspected: 30 -MAY -18
Permit CLINT HOS'I'ETTLER
Holder:
PO BOX 867 RIFLE 816500867
Phone: (970) 625-5192 Fax: (970) 625-1977
Email: ADMIN c7WALKER-ELECTRIC.BIZ
Site: 988 GAGE RD Rifle County: Garfield
Owner: Tally Ho Const Phone: (970) 625-5192
Tally Ho Const
Status: REJECTED
Inspection Type: Rough In Trim Permit: N
Constuction Type: NEW Building Type: RESIDENTIAL
Inspector: Justin Samuels 855-454-0068
Corrections: 1. Still unable to verify size of bonding jumper to building steel. Must be awg 1/0 cu per tablc
250.102. (appears to be #2 or #3)
Comments: Okay to insulate. Leave off insulation over building steel conductor until size can be verified
next Rough inspection. All other corrections made.