HomeMy WebLinkAboutLetter from Engineer 08.15.2018SCANNED
TALLY HO CONSTRUCTION
145 COUNTY RD 225
RIFLE, CO 81650
RECEIVED
AUG 2 1 2018
GARFIELD COUNTY
COMMUNITY DEVELOPMENT
Jobsite Address: HWY 82 & CATTLE CREEK ROAD
GLENWOOD SPRINGS, CO 81602
SENTINEL
Date: 8/15/18
Sentinel Building Systems Job ID: B38398
Dear Sir:
This letter is to certify that a 50' wide, 98' long gable symmetrical building with a 16' eave height as referenced above and
manufactured by Sentinel Building Systems of Albion, Nebraska is designed in accordance with the following loads:
Live Load: 12 psf (main frame)
Live Load: 20.00 psf (roof system)
Collateral Load: 1 psf
Roof Snow Load: 40 psf
Wind Load: 115 mph Exposure C
Dead Load: 3.300 psf (wt. of the building)
Seismic Zone/Design Category: C
Seismic Coefficient: 0.507 (Ss*Fa)
Loads are applied in accordance with the IBC 15 building code. The certifying engineer does not certify that the building code
or loads specified are adequate or appropriate for the intended use or location of this building. The buyer is responsible to
verify specified loads are in compliance with the local regulatory authorities.
Design is in accordance with the applicable sections of the 2010 ANSI/AISC 360-10 and the 2012 AISI 5100.
This certification is limited to the steel framework, the metal roof and the metal wall covering, and fasteners required for their
installation. This certification specifically excludes an analysis of the foundation and parts supplied by anyone other than
Sentinel Building Systems.
Sincerely,
SENTINEL BUILDING SYSTEMS
FK In Gottier
Building Designer
i
David M. Woebbecke, P.E.
Certifying Engineer
TF 800.327.0790 I P 402.395.5076 1 F 402.395.6369 I sentinelbuildings.com
Sentinel — Main Office
237 South 4th Street, P.O. Box 348
Albion, Nebraska
USA 68620
AGI