HomeMy WebLinkAboutEngineer's Inspection Report 06.06.2018West Slope Testing & Inspection LLC
3177 Glendam Dr.
Grand Junction, CO 81504
Phone: 970-434-6988
Cell: 970-260-2844
Inspection Report
Report #1
Page 1 of 1
Date: 6-6-18
Project: Commercial Building for ECOS Environmental Disaster Restoration
Address: 6690 Hwy 82 Garfield County, CO
Building Permit No.: BLCO-2-12-2364
Inspection of shop fabrication or field work at job site: Field
Report: Inspected high strength A325 bolting at the steel beam & column
connections on the project.
The high strength bolting inspected above appeared to be in substantial
conformance with the plans, and the AISC/RCSC Specification for high strength
bolting.
To the best of my knowledge this completes the special inspections of the high
strength bolting on the project, as outlined above.
Douglas E. Young
C Certification #51022
1 We ing S
Inspector/Technician: Douglas E Young St 1 & Btin
ray -applied Fire pro o
or
al Inspector
g pecial Inspector
t, Douglas E Young
CWI 96070131
QC1 EXP. 7/1/2020