HomeMy WebLinkAboutInsulation Compliance Certificate 09.12.2018Project REScheck Software Version 4.6.5 Compliance Certificate 145-080678 Energy Code: Location: Construction Type: Project Type: Conditioned Floor Area: Glazing Area Climate Zone: Permit Date: Permit Number: 2009 IECC Carbondale, Colorado Single-family New Construction 1,350 ft2 3% 5 (7313 HDD) Construction Site: 0067 Meadow Wood Road PO Box 1971 Carbondale, CO 81623 Owner/Agent: Joe or Melissa Lott 0067 Meadow Wood Road PO Box 1971 Carbondale, CO 81623 Designer/Contractor: Allied Design Architectural and Engineering Group, P,C. PO Box 110 Morton, IL 61550 Compliance: Passes using UA trade-off Compliance: 15.9% Better Than Code Maximum UA: 389 Your UA: 327 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Assembly Gross Area Cavity Cont, or R -Value R -Value U -Factor UA Perimeter Wall 1: Other Wall Comment: North Window 1: Vinyl/Fiberglass Frame:Double Pane with Low -E Wall 2: Other Wall Comment: South Door 1: Solid Wall 3: Other Framed Wall Comment: East Window 2: Vinyl/Fiberglass Frame:Double Pane with Low -E Wall 4: Other Wall Comment: West Window 3: Vinyl/Fiberglass Frame:Double Pane with Low -E Door 2: Solid Ceiling 1: Raised or Energy Truss Floor 1: Slab-On-Grade:Unheated Insulation depth: 4.0' 420 12 420 288 630 24 630 24 40 1,350 150 0.0 30.0 10,0 0.045 19 0.280 3 0.045 6 0.250 72 0.045 28 0.280 7 0.045 26 0.280 0.350 0.031 0.684 7 14 42 103 Project Title: 145-080678 Report date: 09/12/18 Data filename: M:\Project Information\145\145080678\PR\145-080678-REScheck.rck Bay Space Column Width Column Depth Nailer Spacing Nailer Width Nailer Depth Stripping Spacing Stripping Width Stripping Depth Wood R -Value U -Value Calculation for a Wood Framed Wall (based on the Isothermal -planes Method from ASHREA's Fundamentals Handbook) 7.5 ft 4.5 in 5.5 in 24 in 5 in 1.5 in 32 in 3.5 in 1.5 in 1.25 per inch Layer R -value % of WaII Exterior Air Film 0.17 100.00% Exterior Sheathing 0.62 100.00% Air Space 0.91 79.17% Exterior Wall Framing 1.875 20.83% Insulation 19 95.00% Column 6.875 5.00% Interior Wall Framing 1.875 10.94% Air Space 0.91 89.06% Interior Sheathing 0 100.00% Interior Air Film 0.68 100.00% Layer Layer Components Layer Component Percentage R -Value Layer R - Value 1 Exterior Air Film 0.170 0.170 2 Exterior Sheathing 0.620 0.620 3 Airspace 0.720 1.111 Exterior Wall Framing 0.391 4 Insulation 18.050 18.394 Column 0.344 5 Interior Wall Framing 0.205 1.016 Air Space 0.810 6 Interior Sheathing 0.000 0.000 7 Interior Air Film 0.680 0.680 Total Assembly R -Value 21.990 INSULATED CAVITY LAMINATED COLUMN Total Assembly R -Value 21.9903 U -Factor 0.0455 EXTERIOR AIR SPACE EXTERIOR NAILERS EXTERIOR AIR FILM INTERIOR AIR SPACE INTERIOR STRIPPING - INTERIOR AIR FILM Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements list -42..41.21v, t.. eck Inspection Checklist. ilix 4 Name Title 5ignarr�n� Uet Date •• ■ c'a f . ite Project Title: 145-080678 Report date: 09/12/18 Data filename: M:\Project Information\145\145080678\PR\145-080678-REScheck.rck