HomeMy WebLinkAboutOWTS Installation Observations 10.25.18October 25, 2018 Project No. C1399 Karl Buhlman kbdreams73@yahoo.com Onsite Wastewater Treatment System (OWTS) Installation Observations 9404 CR 325 Garfield County, Colorado Permit Number SEPT-04-18-5200 Karl, ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OW TS) on October 23, 2018 for the subject property. You, the property owner, installed the system. A new 4-inch diameter SDR-35 sewer line with a double sweep clean out was installed at the new ADU. A new, 3-inch diameter SDR-35 sewer line was also installed from the existing septic tank to the inlet side of the new septic tank. You opted for the smaller diameter pipe in this case. The sewer line come AFTER the existing septic tank serving the main house and therefore the reduced diameter of the sewer line should not cause a problem. The installation included a 1000-gallon, two-compartment Valley Precast concrete septic tank with an Orenco® ProPak and an Orenco® PF3005 pump. Risers bring both side of the septic tank to grade for access. The inlet tee was present. There is an effluent filter inside the second compartment of the septic tank. This filter must be cleaned annually, or as needed. The floats were set to dose approximately 80 gallons each pump cycle, allowing approximately 13 gallons for drain back. The control panel for the pump is located within line of sight of the septic tank. We tested the pump and alarm via the floats during our site visit and they were functioning properly. There was no water in the septic tank to set the pump line up to the distribution box. A 1.5-inch diameter Schedule 40 pump line was installed from the pump to a new distribution box, located at a high point above the existing soil treatment area (STA). The distribution box is located near the existing septic tank serving the main house and risers make the distribution box accessible from grade. You were in the process of connecting the existing STA to the distribution box at the time of our inspection. The existing STA is located above the driveway. Inspection ports are present at the end of the STA trenches. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed By: Carla Ostberg, MPH, REHS Richard H. Petz, P.E. Inlet lines running into tank (from main house and ADU) hard angle from main house – just effluent Inlet pipe Pump line existing tank 1.5” diameter Schedule 40 pump line Pump line in same trench as 3-inch diameter sewer line from main house tank / covered with blue board Distribution box connecting to two lines to existing STA Pump line from lower tank 3” sewer line from main house tank Sewer line to one section of STA Sewer line to other section of STA View of distribution box (JOSA s~~ ~'~ \'\~~ L 1 \I \ q\\ I <>CJ~d---\\\J ~\1 c;~~~ \'()~~"!__, ! 1109 ... "\.it, JOS<a]~o'.~ ~~~('\\ °ft. -:iN -en 1 m?li d) o-lr~ S1-.~ k~~ ~Q\.i~ ~\N t-1 Ci~~ \'°~\ J\~_s I ~ ~ '.S PERMIT KEEP AVAILABLE AT PROJECT SITE Project Address ____________________________________________ Parcel No. ________________________ Subdivision _________________________________ Lot _______ Section-Township-Range ____________ Owner Name ______________________________________________ Owner Phone _____________________ Owner Mailing Address _______________________________________________________________________ Contractor(s) ______________________________________________ Contractor Phone _________________ Work Description: Valuation _________________________________ Square Feet _______________________________ IMPORTANT: APPLICATION IS HEREBY MADE TO THE BUILDING OFFICIAL FOR A PERMIT SUBJECT TO THE CONDITIONS AND RESTRICTIONS SET FORTH ON THIS APPLICATION. PLEASE NOTE: Final inspection of the work authorized by this permit is required. A Certificate of Occupancy must be obtained prior to use and occupancy of new buildings and structures. A Building Permit becomes null and void if the authorized work is not commenced within 180 days of the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement. Permit Type ____________________________________ Work Classification _____________________________ Issue Date ___________ Expiration Date ___________ PERMIT # Community Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 Phone (970) 945-8212 11/11/2018 27-04-92 Septic - ALT/ Repair 970-625-1231 OWNER 9404 Hwy 325 Rifle, CO 81650 Alteration of existing septic to allow for change of use of structure SEPT-04-18-5200 192327400064 Alteration 5/15/2018 Carrie Buhlman 9404 HWY 325 832‐R‐13‐002