Loading...
HomeMy WebLinkAboutEngineer Report 11.14.18Gregg Mackcy, OWTS 050 c,R, I l0 SE Job No. 18197.01 Novembet' 14,2018 OWS Oueration and MaÍntenance Orvnershi¡l of the system and responsibility for uraintenance and repair rvill retttain rvith the property Orvnel'. The Os,ncr is ãncourngãd to rotain the services of qualified persottnel to irrspect the OWTS and to perfonn all maintenance aucl ripairs uecessary to eusure that the systenr courpotrents ate rnaintaittecl in good operating condition and st¡itable vegetaiive cover is "itolrlirlt".l on the fields. The comporrents of the OWTS systent shoulcl inspected rvithin 30 claysãf being placed into operation arrd shoulcl been inspected and maintairted bi-annually. The tank, absor.¡ltion frel¿ and othèr system cornponents shoulcl be visually inspected bi-annually for debris, darnage, leaks, or other potential problenrs. IÀ general, for a properly utilized systern, septic tanks should be purnped every 3 - Syears. The eifluent filler should be ðleaned every six ¡¡ronths and at the tirne of punrping. Absorption fÏelds shor¡lcl be I¡aintained rvith suitable vegetative covei and kept free of root invasive ¡llants. Positive sttrface cltainage arvay fronr the absorption field shoulcl be maintained. If you have any qgestiott or neecl arry additional informatiott, please call' Sincercly, SOPRIS ENGINEERING, LLC - ''{''1 ':-' --. J-4 . '',t'1/¿' ¡-r¿¡ I, PEPaul E. Rutledge Design Engineer Principal RÊG