HomeMy WebLinkAboutApplicationGarfield County
GRAÐING PERMIT
APPLICATIONn r c E r ffif ïir*r?."ä:i,1_" lt D epa nm en t
DËü i o rplf lenwood Springs, cO 81601.. = ilrri
1970,) 945-gZlzGARFIELDCOU@
COMMUN lTY OEVELOPMEi¡T
TYPE OF GRADING
EI MAJOR
INVOLVED PARTIES
tr MINOR
Property owner: Terra Energy Partners Phone: t979-l 285-9377
Mailing Address:1058 County Road 215, Parachute, CO 81635
EmaitAddresr. Bryan Hotard BHotard@terraep.com
contractor: TLC Construction Phone 285-2069
Mailing Address: 213 Ðiamond Loop, Parachute, CO 81635
Ëmail Address:TLÇpipeline@TLCpipeline, com
4¡çh¡1sç¡, N/A Phoner (_)
Mailing Address:
EmailAddress:
Eric Zamora (Williams Bargath, LLC)Phone:3 726-4720
Engineer:
Mailing Address:2717 Qounty Road 215, Sulte 200, Parachute, CO 81635
Ema i I Ad d res, Eric,Zamor a@williams. com
PROJECT NAME AND LOCATION
Project Name . Solvay Fuel Gas Pipeline Project
Describe Work:lnstall a2" luel gas pipeline on pr¡vate surface. The pipeline willtie
into the existíng WÍlliams 20" De Begue lateral pipeline to the Colorado lnterstate
Gas pipeline from the south and deliver gas to the Solvay tacility to the north,
Job Address:Section 34, Township 6 South, Range 96
Assessor's Parcel Number:2409022001 48 and 217 1 -343-A0-022
Sub.Lot _Block
Earthwork (square feet)- 2j0 acres Ëarthwork (Cubic Yards):
Eric is the Permil Applicant, any ture corresp ence should go through him
besides the
let Eric know
lf you need additional
acrea and what the
ates of clirt work
ures show,
ALL UTIL¡TIES MUST BE LOCATED PRIOR TO ANY GRADING
NOTICE
lherebycertifythatlhavereadthisApplicationandthattheinformationcontainedaboveistrueandcorrect. I
understand that the Building Division accepts the Application, along with the plans and specifications and other
data submitted by me or on my behalf (submittals), based upon my certification as to accuracy. Assuming
completeness of the submittals and approval of this Application, a Building Permit will be issued granting
permission to me, as Owner, to construct the structure(s) and facilities detailed on the submittals reviewed by the
Building Division. ln consideration of the issuance of the Building Permit, I agree that I and my agents will comply
with provisions of any federal, state or local law regulating the work and the Garfield County Buildlng Code, OWTS
regulations and applicable land use regulations (County Regulation(s)). I acknowledge that the Building Permit
may be suspended or revoked, upon notice from the County, if the location, construction or use of the structure(s)
and facility(ies), described above, are not in compliance with County Regulation(s) or any other applicable law,
I hereby grant permission to the Building Division to enter the property, described above, to inspect the work. I
further acknowledge that the issuance of the Building Permit does not prevent the Building Ofiicial from: (1)
requiring the correction of errors in the submittals, if any, discovered after issuance; or (2) stopping construction
or use of the structure{s) or facility{ies) if such is in violation of County Regulation(s} or any other applicable law.
Review ol this Application, including submittals, and inspections of the work by the Building Division do not
constitute an acceptance of responsibility or liability by the County of errors, omissions or discrepancies. As the
Owner, I acknowledge that responsibility for compliance with federal, state and local laws and County Regulations
rest with me and my authorized agents, including without limitation my architect designer, engineer and/ or
builder.
I hereby acknowledge that I have read and understand the Notice and Certification above as well as
have provided the requi red ¡nformation which is correct and to the best of my l<nowledge
Property Owner Print and Sign
Authoritv. This application for a Building Permit must be signed by the Owner of the property, described above, or
anauthorizedagent. lfthesignaturebelowisnotthatoftheOwner,aseparateletterofauthority,signedbythe
Owner, must be providecl with this Application.
LesalAccess. ABuildingPermitcannotbeissuedwithoutproofoflegalandadequateaccesstothepropertyfor
purposes of inspections by the Building Division.
Other Permits. Mult¡ple separate perm¡ts may be required: (1) State Electrical Permit, (2) County OWTS Permit,
{3) another permít required for use on the property identified above, e.g. State or County Highwayl Road Access or
a State Wastewater Discharge Permit.
Void Permit. A Building Permit becomes null and void if the work authorized is not commenced within 180 days of
the date of issuance and if work is suspended or abandoned for a period of 180 days after commencement,
CERTIFICATION
OFFICIAT USE O]NLY tg {*.1ØÐ.?l3t Ø
speciarconditio""f,¡-{. {iæ"r+ø CÅrøtrctl\
Misc Fe¡si\\ ITì
Fees:ooTotalôqff)'ffü'îm fr"'#j[;;¡n, oo
Grading'Permit
Ct?fil\- t( nàHt ¡:*J nr hq
¡ssue Datei Zoning:
PL
Balancgduel 00ó/'j:
12-21.1Ø
T
Date
BUILDING / PLANNING DIVISION
CONDITIONS TO ALL PIPELINE GRADING AND INSTALLATION PERMITS
FOR GARFIELD COUNTY
1.. All work to comply with ASME 83L.8-2007 and manufacturers recommendations for steel
pipelines.
2. All work to comply with ASTM D2774 for pressure poly pipe installations and ASTM D232L1or
gravity flow poly pipe installations. Follow all manufacture's recommendations.
3. Minimum cover over all installations is 48 inches.
4. Properly compacted backfill is required between parallel pipes in a common trench. Provide
adequate space between the pipes to achieve adequate compaction.
5. The trench bottom should have stable (firm)soils and free of protruding rocks. A minimum of 4
inches of Class I bedding is required under poly pipe.
6. Compaction requirements are 85% standard Proctor for Class I and Class ll backfill (including
padding), 90% standard Proctor for Class lll backfill, and 95% standard Proctor for Class IVA soils
and for all backfill under and within 6 feet of roads. Maximum lifts of l2-inches for Class l, 8-
inches for Class ll, and 6-inches for all other classes. Compaction test are required every 200
feet until compaction practices meet these requirement. Compaction once established must be
spot checked every 400 ft. or when fill materials or processes changes.
7. Padding (shading) of all pipes is required a minimum of 24-inches around the pipe with 12-
inches of padding over the pipe. Padding particle size of no greater than 1 I/2 -inch for a 1-0-
inch to l5-inch diameter pipe. lf the p¡pe is 16-inches or larger, the 2 inch maximum particle ¡s
allowed.
lnspection Reports shall be completed to verify the above specifications. ln addition the reports shall
show:
o Name of the inspector, date, time on site, and weather;
o A description of the work in progress;
¡ Summary of conversat¡ons with contractors/others;
o Summary of sampling and test¡ng activities;
¡ Verification of pipe material, grade and alignment;
o Observation of pipe installation, placement of padding and backfill materials, and trench
excavation methods;
r Verification of proper pipe storage, handling, and installation procedures are followed;
r Copies of all pressure integrity, non destructive X-Ray and compaction test; and
¡ Pictures to document the construction.
Stormwater management plans require routine inspections during all phases of work every 14 days and
after a precipitation-related event.