Loading...
HomeMy WebLinkAboutApplication- Permit04219 GARFIELD COUNTY BUILDING, SANITATION and PLANNING DEPARTMENT 109 Bth Street Suite 303 Glenwood Springs, Colorado 81601 (303) 945-0212 Job Address 7 722 C.a..115 Carbond J„e Nature of Work Buildit ; Penni t Use of Building Addition Owner Lyz►d Marsh Contractor Laser Nifhtsky Amount of Permit: $ 437.25 date: 1y 21 1991 Permit $265.00 Plan $172.25 R. Bennett Clerk White - Trees. Canary - Office Pink -Applicant Gold - Duplicate 1 C74 9' I _67.A5 eSS Cs /greed/ # TO JE FILLED OUT BY APPLICANT ADDRESS L SUBDIVISION 17 rr f ., % 6.4"-r. % FILING # LOt ; -' BLOCK #d 7'AX SCHEDULE # 207 co LEGAL (SEC/TWN/RNG) NAME MAILING ADcRESS TM -Lc GARFIELD COUNTY APPLICATION FOR BUILDING PERMIT p7case print or type a CITY 6-1c ^. 1.30 4 Gkl PHONE L4C jL/ NAME fie. 4 11,rig ADDRESS .A.0 '3 _ J C TTY NAME LZS4..C.�i ADDRESS CITY 6 PHONE a 012 LICENSE # CLASS OF WORK NEW_ __ _ ALTERATION ADDITION DEMOLISH REPAIR MOVE MOBILE HOME (make/ yodel) S.F. OF BUILDING ct S.1. OF LOT # OF FLOORS HEIGHT Cr # OF FAMILY UNITS 1 # OF BEDROOMS INTENDED USE OF BUILDING l 1 ot6.- GARAGE: SINGLE DBL CARPORT: SINGTd. DBL FIREPLACE 1 DOCUMENTS ATTACHED? _WATER SUPPLY 1;5-1A DRIVEWAY PERMIT e • SITE PLAN 1 BUILDING PLANS r% SANITARY SEWER CLEARANCE 0`{"` ON SITE SEWAGE DISPOSAL PERMIT frita OTHER DOCUMENTS (specify) O 4Y1 -m''. 4,5iot 61 FOR OFFICE VALUATION 47, ¢c , ,3 PERMIT FEE $ P LAN CHECK FEE $/-71,...2...r TOTAL FEE $14,31:47...- SCHOOL IMPACT FEE $ Al 4 - DATE PERMIT ISSUED ZONING DISTRICT TYPE OF OCCUPANCY TYPE OF CONSTRUCTION S.F. OF BUILDING '08 S.F. OF LOT ,c . MAX. HEIGHT - 1- ' ROAD CLASS. -- SETBACKS FROM PROPERTY LINE: FRONT REAR RIGHT LE T OFF STREET PARKING SPACES REOr;IRED 711111111 PERMIT NUMBER 'ioti `i DATE 5 PLOT PLAN NOTE: Show easements, property line dimensions, all other structures, specify north, and street name. For odd shaped 1otE, or if space is too smal, provide separate plot plan. # OF BUILDINGS NOW ON PARCEL USF OF BUILDINGS NOW ON PARCEL P f h h FRONT PROPERTY LINE STREET NAME/ROAD NUMBER 371-L tis CHECK IF CORNER LOT DESCRIPTION OF WORK PLANNE f `I I d1 T tdr dot M go."`G11J* hovjllFa I hereby acknowledge that I have read this application and the above is correct and T agree to comply with all county ordinances and state laws regulating building construction SIGNATURE USE ONLY FLOOD HAZARD CERTIFIED BLDG ELEVATION SPECIAL CONDITIONS PROBLEMS WITH PERMIT ADDITIONAL INFORMATION NEEDED CERTIFIED BY COLORADO REGISTERED LAND SURVEYOR OR ENGINEER APPROVED: ILDING DEPART NT A- T J APPROVED: PLANNING DEPAR ' E DATE . 1 . i . . 1 ki; ZeLl/PA:.. 41 ,01.14P S,-/ . •/0/ . _ II /9'2- ' .. • • 4., N . # ., ,/,). x I -- - "li 74- 27 4 ' 22 , 8 . - ,.q.,L, „J../ • 'L ' ,-k 2-4 4.-------------- 7......, 6 ;4 1-942-4 ./ (9. 4:• -r - 8O , ii '----- • C.._.7.71 th m • tz r 1 :1 I 4. :16Z (Jr) \ I -- ,•- 1[ .72•Li X., t. 7 North Exterior View Front (South) scale; 1' = 0,5 Errrryrril = chuffing perpendicular wall 24' 7 Entry/Utility Doom * l #+ r! e I Utility Roam 'f ± ± + rrrj r Mft fx�'e% fry • N. \ 1 % % / 1 l f / NI •'½' 1N; J 7' /J 1' 1 F 6' •hlkrk:141% • + + h 1 % 1 % h141%J\1�1R kf\f\\\f3 1 f 4141%;%;%1M h h \ \ \ } t 1% r t 16' 1 r 111111 West Exterior View 2 x 6 ceiling ialsts16' o.o. sheet rock calling existing roof overhang ry e. e. e. e. e. 7 S' existing north wall Interior Wall Front (South) 8' { / T. eclat exterior wdlt has an operation window opening window Family room, East 6d Interior Walls e' x 12' x20' glulamb bsnm extends to west exterior WaII, ends here 2 x 6 collar ties In greenhouse/ storage rooms only Front (Soutt)) $ • rr • • . . + . cf x "` wol ; + r 4 r 1' r• r closet • • / r.r r • • r r 1 • r • r r • • • ; •59 r rt 43,5' xIntersect - f ; •, 'P.: r r 1 • r e r 1 • j I 1 _ 28x80 r f • • r i 13' 2' 4' Storage, South Closet Wall existing wil 18' existing wall •.. ..+ .. f . 48x' 80 louvered w $; r: r r r, . r. r. I. I r, A r, 6 ' ;1 ;9 "i •. .I 'r '. .A A •. f ; •, 'P.: r r 1 • r e r 1 • j I 1 'T. scale: 1' = 0,5 cm Lozzeavezzi abutting perpendicular wall 8' closet Interior woks 2 4' Front (south) not pictured here: dock railing; see below 3/4' ply w Roof 2x88Joist scale: 1' = 0.5 cm Z. abutting perpendicular wall 18' 28' bb Walls: South & West 10' 6' 8 f f 19 x 59' open 6' 10" Side (west) 21' 2' slope of hill 6.83' 3'10' x 12' x 20' glulomb beam extends to Interior divider wall r closet 124 46 41" opening 20' ----- 22' 10" deck rolling: also goes around front of deck 1x6 fascia Rao Insuldlbn 112 PIY 2 x 8 ratters 16' P.C. (11.4 hortxartal span 3/8'ro/s ply 6a Walls: Typical asphalt shingles A11 2 x 6 Conor ties 16' c.a. heat rock 55 R13 Insulation :11 • 5/8" urethane ii •/B' ra/s b & 8 Ply w 4 /4" plywood R11 irlsuI M1on x811Jolst x 6 sill, treated stem wall Gating 1x6tongue & groowe ceiling Front (south) b' 10" grade 18' 28' 5b: Foundations; South Wall 10' 8' A. 1. 21'2' 4' x 4 3 x S' QQting: 9' deep, 16'wlde scale: 1' = 0.6 cm marker: 38' below grade Stem wa 9' wide or rdde • North Typical footing & stem wall 23' 5" grade foundation Is 'stepped': see drawing 5c 5a: Foundations; overview & measurements Typical roofing & stem wall "NIIIIIIIIIIIIIIIIII 111..._ S. N. beam far \ 8' 3.6" foist support 9' 6.6' ---1 9.5L .; 24 7' Typical footing & stem wall faundatbn is 'stepped': sae drawing 6 scale; 1' = 0.2cm = existing window ® = footing: 18" x 8" x 11 m` deck - concrete pad: 2' x 2' x 10' treated 2 x 6 sill w anchors 6' o.c. Crass section of Typical Fpoting & Stam Wall 44" 36' Section showing beam to support floor joists 4 x 6 posts hillside 1,_.(t i) 6' 9' vents: 9 total, 2 per side except For E &W wall of entry w 1 /side at least 6" above grade at least 39" bedew grade • tem wall: 2 #4 mbar top & boltom, w #4 rebar vertical a 4' o.c, F=ooting: 2 !4 rebar awn obOV9 3 2x12 bulli up beam regting on 4 x 6 posts on tap of stem wall or pad 2 x 9 floor Joists, 11' 6' . 16" a.c. l t 22' 10" North 18' ,Iot r- 1Q 4 House + Additions; Measurements 24' 16' entry utINy g 97 9'6 12' 2' 2 1 ME - - 13' Gfeen- i house 9' 8' ' 3' 28' scale: 1' - O.2cm • 1 i -4 36' = existing window chimney deck 1 $, = new wall a new window 8' J- scale: V = 0.2cm: 1 cm = 5' v= window —.Iii MN= - = chimney j = deck 42' 12' 2' 2: Original house; Measurements North H 5' 6' .1,8' 6' b' —i , 8' L 24' PERMIT if OWNER„, 4' )/ 41./eS6(LOCATION ,3742 //,S CONTRACTOR THE FOLLOWING ITEMS MAY HAVE BEEN OMITTED FROM YOUR PLANS OR MAY NOT COMPLY WITH THE PROVISIONS OF THE UNIFORM BUILDING CODES. PLEASE CHECK ALL CIRCLED ITEMS BEFORE BEGINNING CONSTRUCTION. ALL REFERENCES ARE 1988 EDITIONS OF THE CODES. THESE ITEMS ARE REQUIREMENTS FOR R-3 OCCUPANCIES ONLY (ONE AND TWO FAMILY DWELLINGS) AND ARE NOT ALL INCLUSIVE OF THE CODE REQUIREMENTS, BUT ARE MEANT AS A GUIDE TO SOME OF THE MOST OFTEN ENCOUNTERED QUESTIONS RELATED TO CODE REQUIREMENTS. THE APPROVED PLANS RETURNED TO YOU SHALL BE KEPT AT THE BUILDING SITE DURING CONSTRUCTION. FOR ANY REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE CONTACT THE COLORADO ELECTRICAL INSPECTOR. THERE SHALL BE A FINAL INSPECTION AND APPROVAL OF ALL BUILDINGS AND STRUCTURES WHEN COMPLETED AND READY FOR OCCUPANCY AND USE - UBC SEC. 305 (d). Concrete for foundations and load bearing slabs is required to be 3000 psi in 28 days - UBC Chapter 26. Mortar and grout shall be in accordance with UBC Chapter 24 & Table 24-A and 24-B. Masonry units, mortar, and grout shall be protected during cold weather in accordance with UBC Sec. 2404 (c). Concrete shall be protected during cold or hot weather in accordance with UBC Sec. 2605 (f) and (g). ,DOKMinimum concrete and/or masonry foundation reinforcement requirements are shown on the attachment. (Note: these minimums apply only if a foundation soils invest1g t n isnot performed and the soils are assumed to have an, expansion index of 20 or less and footing loads less than 2000 lbs/linear foot - UBC Sec. 2904 (a) and (b) and Sec. 2906. 4Foundation frost protection is 30" from finished grade to top of footing - UHC 2907 (a). Foundations shall extend a min. of 6" above finished grade - UBC 2907 (d). Provide for the control and drainage of surface water away from the building - UBC 2907 (f). 7. Foundation walls enclosing a basement below grade shall be damp -proofed on the exterior with approved materials - UBC Sec. 1707 (d). .7) Foundation Foundation plates or sills shall be redwood or pressure treated wood (UEC - 2516 (c)), and shall be bolted to the foundation with not less than 1/2" dia bolts embedded at least 7" into concrete or masonry, spaced not more than 6 feet apart, min. of 2 bolts per piece and within 12" of each end of piece - UBC 2907 (f). Exterior concrete or masonry piers shall extend 8"� in.,above_grade unless the posts or columns which they support are treated or-decay'"resistant woo. Columns and posts located in basements shall be supported by concrete piers or metal pedestals extending 6" min. above earth and 1" min. above floor unless treated or decay resistant wood - UBC Sec. 2516 (c) 4. 10. Manufactured trusses, and manufactured joists and beams (i.e. TJI/Micro-- Lams, BCI/Versa-Lams, Glu -Lams, etc.), shall be sized and installed in accordance with the manufacturers requirements. Wood joists or floor beams located closer than 18" or wood girders closer than 12" to the ground in crawl spaces shall be treated or decay resistant wood - UBC Sec. 2516 (c) 2. 12 Girders supported by masonry or concrete shall have 1/2" air space at top, sides, and ends unless treated or decay resistant wood - UBC Sec. 2516 (c) 5. Ends of beams and girders shall have min. 3" of bearing on masonry or concrete - UBC Sec. 2517 (c). 13. Floor joists under and parallel to bearing partitions shall be doubled UBC 2517 (d) 5. 9 Floor joists require full depth solid blocking and must lap a min. of 3" over bearing supports - UBC 2517 (d) 3. 15 Beams, roof rafters, and ceiling and floor joists shall be supported laterally in accordance with UBC 2506 (h). TOColumns, posts, beams, and girders shall have positive connections provided to ensure against both uplift and lateral displacement-.IJBCSec. 2516 (m). 1„ Ends of floor joists shall have 1 1/2" min. bearing on wood or metal and no less than 3" on concrete or masonry - UBC Sec. 2517 (c) and (d) 2. 18. Notches on the ends of floor joists - max. 1/4 joist depth. Bored holes not within 2" of top or bottom of joist and hole diameter no larger than 1/3 depth of joist. Notches at top or bottom shall not exceed 1/6 depth and not located in middle 1/3 span - UBC Sec. 2517 (d) 3. 19. Floor joists and/or roof rafters are insufficient for the span - UBC Table 25--11-J-1 and UBC Standards. 20) Roof live load (snow load) shall be 40 psf below 7,000 feet elevation -UBC Sec. 2305 (d) -dead loads shall be as required in UBC Sec. 2305. v. £ dao, =y=119 l—p.Jm 4,Q un Gn. k'JUk I1 al.4Jly Wit.IJUZ----Er--QO'6t'- opening ..LD.._ -rue exterior shall have at least one operable window that meets the following requirements: MAXIMUM sill height: 44" MINIMUM net clear opening height: 24" (x34 1/4" - 5.7 sq.ft.) MINIMUM net clear opening width: 20" (x41" = 5.7 sq. ft.) This also applies to basement sleeping rooms - UBC Sec. 1204. 41 Glazing in hazardous locations as defined in UBC Sec. 5406 (glazing in doors and adjacent to doorways, and glazing in windows located within 18" vertically of a walking surface) shall be safety glazed or protected. 42. Glass in sloped glazing (more than 15 from the vertical) and skylights shall meet the requirements of UBC Chapter 34. Skylights and roof and wall panels of light -transmitting plastics shall meet the requirements of UBC Chapter 52. 43. Provide combustion air for fuel burning equipment per UMC Chapter 6. 44. Pressure relief valves and/or combination pressure/temperature relief valves shall be provided with a drain line to a floor drain with min. 1" air gap 3 r • or extended to the exterior of the building - UPC Sec. 1007. 45. Domestic dishwashing machines shall not be directly connected to a drain or waste. disposer without the use of an approved airgap - UPC Sec. 608 (d). 46. Fuel burning appliances shall not be located in any room used or designed to be used as a sleeping room, bathroom, or closet or any enclosed space opening into such room or space* UPC Sec. 1309 and UMC Sec. 704 (unless listed for such use). 47. Appliances (including space heating and water heating equipment) shall be accessible for repair and removal in accordance with the UMC. 48. LPG fueled appliances shall not be installed in a pit, under -floor (crawl) space, or basement - UMC Sec. 504 (f). 49. Appliances located in a garage (or in an enclosure opening into a garage) shall be located out of the normal path of vehicles or protected from damage. Any portion of the appliance creating a flame, spark or glow shall be installed a min. of 18" above the garage floor - UMC Sec. 508. 50. Each water closet stool shall be located in a clear space not less than 30" in width and 24" in front of stool - UBC Sec. 511 (a). 51. Toilet rooms without operable windows shall be equipped with an exhaust system ducted to the exterior - UBC Sec. 1205 (c). 52. Showers and Tub/Shower enclosures shall have a smooth, hard, nonabsorbent surface to a height of 70" min. above the drain inlet - UBC Sec. 510 (b). Water-resistent gypsum board shall not be used over vapor barriers, in saunas or steam rooms, or on ceilings - UBC Sec. 4712. 53. Attic access opening of not less than 22" by 30" is required - UBC Sec. 3205 (a). 30" by 30" if mechanical equip. in attic space .. UMC Sec. 708. ID Enclosed attic and rafter spaces shall have cross ventilation of min. 1/150 of the area of the space ventilated. The area may be 1/300 if provided equally at lower and upper portions of the space with min. 3' vertical separation of locations - UBC Sec. 3205 (c). 55. Garage side of common wall between living space and garage shall be finished with materials approved for one-hour fire -resistive construction. This also applies to ceilings and bearing walls if living space above the garage. Self closing min. 1 3/8" solid door is required between house and garage--- T,JBC 503 (d) 3. --- 56. Electrically wired, interconnected smoke detectors are required in all sleeping room access areas, near the top of stairways in upper levels, and near the bottom of stairways to basements - UBC Sec. 1210 (a). 57. Wood stoves and factory built chimneys, and manufactured fireplace units and venting systems shall be installed in accordance with the manufacturers listing requirements and inspected during installation UMC Chapter 9 and UBC Chapter 37. 58. Masonry and concrete fireplaces and barbecues shall meet the requirements of UBC Chapters 23, 24, 26, 27 and 29. A chimney shall not support any structural load other than its own weight unless designed as a supporting member - UBC Sec. 3703 (a). 59. 60. COPIES OF THE ITEM(S) CHECKED BELOW ARE ATTACHED (Copies of any of the items above or below are available upon request). Excavations, fills, foundations, and retaining walls - UBC Chapters 23 and 29. Retaining walls - UBC Sec. 2308 (b) and 2907 (g) 4. Roof coverings and drainage - UBC Chapter 32 (Roof drains sized in accordance with UPC Appendix D). Roof sheathing - UBC Sec. 2516 (i). Wood combined with (supporting) masonry or concrete - UBC Sec. 2515. Floor sheathing - UBC Sec. 2516 (h). Wiring in plenums - UMC Chapter 10 and NEC. Fire and draft stops - UBC Sec. 2516 (f). Nailing requirements for connecting wood members__ - UBC Sec. 2516 M . Enclosure of elevator, vent; ani dumbwai dr shafts, and c oThes and rubbish' chutes - UBC Sec. 1706. Exterior wall coverings and exterior weather protection - UBC Sec. 1707 (d) and 2516 (g). Interior application of gypsum wallboard and interior and exterior application of lath and plaster - CJDC Chapter 47. Manufactured wall and ceiling covering systems (simulated stucco, etc.) shall be installed in accordance with manufacturers requirements. Landings and floor level at doors - UBC Sec. 3304 (i). Cross connection control and back flow prevention - UPC Sec. 1002 and 1003. Treated Wood Foundation Systems - UBC Standard 29-3. • • • • • • • • • • • • • • • • • • fe • • • • • • 8 • • 4 • • • •• 4•• O64 No change in the character of occupancy of it building shall be made without a Certificate of Occupancy - (UBC Sec. 3112) May 24 19 3 Permission is hereby granted to }+r► yah .. _ _,.—,-,--- CERTIFICATE OF OCCUPANCY BUILDING DEPARTMENT GARFIELD COUNTY, COLORADO issued Wfthout Fee Building Permit No. 4219 . situated at 3722 County Road 115 • Carbondale for the following purpose Zone District A/R/RD Lot BIk.T Addition Addition to Single Family Dwelling Unit: (State Nature of Use) �, Contractor Laser Nightaky *suance. of a Certificate of Occupancy shalt not be construed as an approval • the provisions of this code or of other ordinances of the jurisdiction. tes presuming to give authority to violate or cancel the provisions at this code or of other ordinances of the jurisdiction shall not ba valid. (LIC Sc . 307(a)). White: Owner Green: Lending Agency Yellow: Build -nt GAR D COUNTY ; UILD t 1 P - !SENT g Depart Pink: Assessor GoId: Contractor