HomeMy WebLinkAboutDesign LoadsENDWALL COLUMN: BASIC COLUMN REACTIONS (k ) Wind Wind Frm Col Press Suct -MIN_SNOW-- Line Line Horz Horz Horz Vert 2 D -4.3 4.7 0.0 7.5 2 C -4.9 5.4 0.0 6.4 2 B -4.3 4.7 0.0 7.5 Frm Col Dead Collet Line Line Vert Vert 5 A 0.9 0.3 5 B 1.7 0.8 5 C 1.6 0.7 5 D 1.7 0.8 5 E 0.9 0.3 Wind Frm Col Suct Line Line Horz 5 A 0.0 5 B 4.6 5 C 5.5 5 0 4.6 5 E 0.0 E1UNB_SL_L- Harz Vert 0.0 19.1 0.0 12.9 0.0 3.3 Live Snow WInd_Let t1 Vert Vert Horz Vert 3.5 8.5 0.0 -5.9 7.6 15.0 3.4 -15.0 6.5 13.2 0.0 -2.8 7.6 15.0 0.0 -6.5 3.5 8.5 0.0 -5.1 ElUNB_SL_R- Horz Vert 0.0 3.3 0.0 12.9 0.0 19.1 Wind_Long1 Wind_Long2 Seis_Left Horz Vert Horz Vert Horz Vert 0.0 -4.0 0.0 -2.4 0.0 0.0 0.0 -9.8 1.4 -7.9 1.5 -1.7 1.4 -8.4 0.0 -5.2 0.0 1.7 0.0 -6.3 0.0 -11.5 0.0 -0.1 0.0 -2.4 0.0 -4.0 0.0 0.0 Frm Col E2UNB_SL_R- Line Line Horz Vert 5 A 0.0 1.9 5 B 0.1 3.3 5 C 0.0 13.3 5 D 0.0 19.5 5 E 0.0 5.0 ENDWALL COLUMN: Frm Col Line Line Wind_Rightl Harz Vert 0.0 -5.1 0.0 -2.1 3.4 -11.0 0.0 -11.2 0.0 -5.9 Segs Rght Horz Vert 0.0 0.0 0.0 1.9 1.5 -2.0 0.0 0.1 0.0 0.0 MAXIMUM REACTIONS, ANCHOR BOLTS, & BASE PLATES Calumn_Reactions(k ) Loud Hmax V Locd Id H Vmax Id 2 D * 12 2.8 -5.8 13 14 0.0 21.4 12 2 C * 15 3.3 -3.4 16 17 0.0 15.0 15 2 B * 18 2.8 -5.8 16 17 0.0 21.4 18 5 A 6 0.0 -2.9 6 1 0.0 9.7 5 B 19 2.8 -8.1 13 20 0.0 22.1 19 5 C 15 3.3 -5.7 13 21 0.0 15.6 15 5 D 18 2.8 -5.9 16 21 0.0 22.0 18 Wind Wnd_Left2 Wind_Right2 Press Horz Vert Horz Vert Horz 0.0 -4.4 0.0 -3.6 0.0 2.8 -10.8 0.0 0.7 -4.2 0.0 -1.3 2.8 -8.1 -5.0 0.0 -2.9 0.0 -7.6 -4.2 0.0 -3.6 0.0 -4.4 0.0 -MI N_SNOW-- E2UNB_SL_L- Horz Vert Horz Vert 0.0 2.8 0.0 5.0 0.0 7.7 0.0 19.7 0.0 6.5 0.1 13.1 0.0 7.7 0.0 3.4 0.0 2.8 0.0 1.9 Hm,n V Bolt(in) Base_Prote(in) Grout H Vmin Qty Dia Width Length Thick (in) - 2.6 2.8 - 2.9 3.3 -2.6 2.8 - 5.8 - 5.8 - 3.2 - 3.4 - 5.8 - 5.8 0.0 -2.9 4 0.625 6.000 12.00 0.375 1.5 - 2.5 -4.8 4 0.625 6.000 8.000 0.375 1.5 2.8 -8.1 - 3.0 -4.1 4 0.625 6.000 8.000 0.375 1.5 3.3 -5.7 - 2.5 -5.9 4 0.625 6.000 8.000 0.375 1.5 2.8 -5.9 5 E 7 0.0 -2.9 7 0.0 -2.9 4 0.625 6.000 12.00 0.375 1.5 1 0.0 9.7 *See Rgid Frame Interior Column Reactions GENERAL NOTES 1. THE METAL BUILDING MANUFACTURER IS RESPONSIBLE FOR THE DESIGN OF THE ANCHOR BOLT DIAMETER ONLY TO PERMIT THE TRANSFER OF FORCES BETWEEN THE BASE PLATE AND THE ANCHOR BOLT IN SHEAR, BEARING AND TENSION, BUT IS NOT RESPONSIBLE FOR THE ANCHOR BOLT EMBEDMENT FOR TRANSFER OF FORCES TO THE FOUNDATION. THE METAL BUILDING MANUFACTURER DOES NOT DESIGN AND IS NOT RESPONSIBLE FOR THE DESIGN, MATERIAL AND CONSTRUCTION OF THE FOUNDATION EMBEDMENTS. THE END USE CUSTOMER SHOULD ASSURE HIMSELF THAT ADEQUATE PROVISIONS ARE MADE_ IN THE FOUNDATION DESIGN FOR LOADS IMPOSED BY COLUMN REACTIONS OF THE BUILDING, OTHER IMPOSED LOADS, AND BEARING CAPACITY OF THE 501L AND OTHER CONDITIONS OF THE BUILDING SITE. IT IS RECOMMENDED THAT THE ANCHORAGE AND FOUNDATION OF THE BUILDING BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER EXPERIENCED IN THE DESIGN OF SUCH STRUCTURES, (SECTION 03 MBMA 2006 METAL BUILDING SYSTEMS MANUAL) 2. BOTTOM OF ALL BASE PLATES ARE AT THE SAME ELEVATION. (UNLESS NOTED) A THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO THE FOLLOWING: DESIGN LOADS DESIGN CODE ENCLOSURE DEAD LOAD COLLATERAL LOAD IBC 15 Closed 3.0 psf 2.0 psf WIND LOAD Basic Wind Speed(3 sec. Gust) 115 MPH Wind Importance Factor 1.00 Risk Category H Exposure Internal Pressure Coefficients Designed pressure for wall Panel Job No. Z18 - 390A 07/12/18 C -0.18 /+0.18 27.00 psf LIVE LOAD 20.00 psf ROOF SNOW LOAD Ground snow Load (Pg) Roof Snow Load Snow Exposure Factor (Ce) Snow Importance Factor Thermal Factor ( Ct) SEISMIC LOAD Seismic Importance Factor Mapped Spectral Response Acceleration Site Class: Spectral Response Coefficients Seismic Design Category: Basic Force resisting system: (OCBF) Ordinary Steel Concentrically Braced Frames (OMRF) Ordinary Moment Frame Tributary Reduction: No 57.E4 psf 40.00 psf 1.00 1.00 1.00 1.00 Ss= 0.3100 D Sds= 0.3207 B S1= 0.0740 Sdl= 0.1184 Analysis Procedure Used: Equivalent Lateral Force Procedure Design Base shear for OMRF: V = Longitudinal 12.02 kips, & Transverse 11.74 kips Seismic Response Coefficients RFCs = 0.0917 BFCs = 0.0642 Response Modification Factor(OMRF) R= 3.50 Omega = 3.00 rho = 1.33 Response Modification factor (OCBF) R= 5.00 Omega = 2.00 rho = 1.50 OTHER LOADS Roof Loads: (3) Roof Exhaust Ventilators @ 193 lbs. each Mezzanine: N / A 07/17/18 n A A ISSUED FOR REVISED 7/16/18 /8\ ISSUED FOR APPROVAL 6/13/18 1111101101� 925 SWOT ,CO, AVENUE EWEST N 80110 1-888-480-5552 BRAEMAR Building Systems 3149 HALDIMAND ROAD 9 YORK, ONTARIO NOA 1R0 1-866-382-5115 CUSTOMERS CMC GROUP PROJECTSN❑W REMOVAL EQUIP STORAGE BLD LOCATIONS RIFLE, CO DRAVN BYE N/A DATE. 6/13/18 JON. Z18 -390A CHECKED BY. DATE. SHECTt A3