HomeMy WebLinkAboutBolt Inspection Report 09.06.2018INDUSTRIAL INSPECTION SERVICES
Special Inspector's Final Report
JOB NAME: Buchman Residence
ADDRESS: 574 Crystal River Road, Carbondale
BUILDING TYPE Residential
INITIAL INSPECTION DATE: August 22', 2018
PERMIT #: BLRE-04-1B-5215 /Garfield County
GENERAL CONTRACTOR: Terralink Structures
WALL TYPE: steel structure / wood framed
LAST INSPECTION DATE: September 6th, 2018
DESCRIPTION OF INSPECTION WORK PERFORMED: Special inspection for field welding / high-strength
bolted connections as required by the 2018 IBC, structural engineer and local building jurisdiction.
LOCATION IN STRUCTURE: Special inspection provided to witness and monitor field welding of full -penetration
groove welds at Moment Frame and A325 bolts at steel -to -steel connections (beams, stiffeners / columns /
structural steel / roof level) as detailed and approved by structural engineer as required.
REMARKS FOR STRUCTURAL STEEL: Witness field welding and high-strength bolting for structural steel erection
and installation of Moment Frame as detailed by Black Magic Welding as designed by Mike Thele Engineering
(structural engineer). Field welding witnessed was performed by certified welders employed by Black Magic
Welding (NON-AISC- approved fabricator) using approved materials and processes. Any weld discontinuities were
corrected in inspector's presence and re -welded in accordance with AWS 01.1./ AISC specifications. No problems
noted. A325 bolts snug tight per engineer's directive. Mill certifications for steel elements reviewed and kept on
file by fabricator.
REMARKS GENERAL: Special inspection on this project was performed per the special inspection
requirements adopted from the 2018 IBC by the Garfield County Building Department as part of the
approved plan.
ALL WORK REFERENCED ABOVE WITNESSED BY INDUSTRIAL INSPECTION SERVICES PERSONNEL,
PERFORMED FROM AUGUST 22n° THROUGH SEPTEMBER 6th, 2018 WAS SATISFACTORILY COMPLETED
AND CONFORMS TO THE APPROVED PLANS, THE 2018 INTERNA
ADOPTED PROVISIONS OF THE AWS D AND THE AISC MA
EDITION). THIS STATEMENT APPLI % D ' ECTLY TOTHOSE`i TO `
SPECIAL INSPECTION WAS PRF -S
SWIM ► 1= D AS PA;� OF T i SWIM b : f cord: ��/ ,iAM/'
sir/
Da/I /1
AL BUILDING CODES (IBC), THE
TEEL CONSTRUCTION (9Th
OF THE STR T J • E WHICH
D PLANS.