HomeMy WebLinkAboutOWTS Design and Construction Report 11.2018WELL COUNTY ROAD NO. 250 ASPHALT LTJ DRAINAGE, UTILITY AND DITCH EASEMENT PER PLAT REC. NO. 544219 LOT 1 3.71AC.f 50 100 LOT 2 —188.7' • — — •-126.7'—• 12 ABSORPTION TRENCHES INFILTRATRORS UAL 19.2' TO IRRIGATION DIT ----N \ INAGE, UTILITYAIvDITCH EASEMENT PER PLAT ILRC. NO. 544219 S 89°21'39" W 379.06' m LOT 4 Waste Water Flow Reference: 5 CCR 1002-43 Section 43.6 Design Flow. 75 gpd/person No. Bedrooms: 3 No. people/bedroom 2 Total Daily Flow 450 gallons (Table 6-1) Percolation Data Percolation tests performed Oct. 13, 2018 No ground water within 8' of the 9round surface Average percolation rate = I 26.8 min/inch IMPORTANT NOTE: On site water was used in the percolation tests. Use of imported water (e.g, City of Glenwood Springs) for tests is invalid , produces erroneous results that do not represent actual percolation rates. Table 10-1 Soil Structure and LTAR LTAR = 0.5 Gal/Day/Square Foot I I I Table 10-2 - Size adjustment for Application Method No reduction; gravity flow for a trench (chanter) I I Table 10-3 - Size ad ustment for distribution media Trench: reduce to 70% of calculated area REQUIRED TRENCH AREA 450 gpd / 0.5 gaVday/SF = 900 Table 10.3 reduction = 0.7 Net Required Trench Area: 630 S.F. Design Recommend Infiltrator brand or equal, low profile 34" wide 48" effective length S.F./Infiltrator 11.33 No. required: 55.6 Use 3 trenches 18.5 - Round to units each trench 19 Total # chambers: 57 I Total length of each trench: 76 Feet Note: Clear distance between trenches 6 feet (measured adjacent sidewall to adjacent sidewall) DESIGN AND CONSTRUCTION NOTES: • Septic tank: 1,250 gallon. Install an effluent filter on the distribution end. • Infiltrator brand low profile chambers or equal. Adjust the following calculations if a different brand or size is used. • Net absorption trench area = 630 s.f • Designed for 3 bedroom home + auxiliary buildings (e.g„ shop) • Design flow = 450 gpd • Average percolation rate = 26.8 min/inch • Soils are deep sandy silty loam, continuous. No water table within 8' of the ground surface. LTAR = 0.5 gal/day/SF. • Each trench: 76 feet long x 34" wide (dig 36" wide). 19 chambers/trench are required. • Trenches shall be as level as possible. Plans show the trenches parallel with the contours. This is optional. • Install 6" diameter PVC inspection ports at each end of each trench. Cover with an irrigation box at grade. • Min. of 18" soil over top of chambers. • Lightly compact fill over top of chambers. Mound topsoil 6"-12" to allow settlement. • Field fit elevations to septic tank / house elevations. • Distribution lines: min. 4" diameter PVC • Use 1x3 distribution / splitter box (gravity) • Place splash blocks under inlets to minimize erosion COMPLIANCE NOTES • Offset to well = 207 feet • Offset to nearest open ditch = 119 feet 24753 et \\ • 41 ON o N ci L- 10 R co U Y U OWTS-ISDS SYSTEM DESIGN AND CONSTRUCTION NOTES ROB & SYLVIA MCLAUGHLIN LOT 1, SIMON SUBD. EXEMPTION GARFIELD COUNTY, COLORADO WATER RESOURCE CONSULTANTS, LLC 244 Hutton Ave., Rifle, CO 81650 I (970) 625-5433