HomeMy WebLinkAboutApplication- PermitJob Address
No. 6332
GARI7ELD COUNTY
BUILDING, SANITATIONand PLANNING DEPABTMENT
109 8th Street Suite 303
Glenwood Springs, Colorado 81601
(303) 945-8212
0102 Sweetgrass, Aspen Glen, Lot G-1, Carbondale
Nature of Work Building Permit
Use of Building Single. Family Dwelling w/Unfinished Basement & Double Garage
ner A & M Builders, Inc.
Ow
Contractor
Owner
Amount of Permit $ 3,316.50 Date June 11, 1997
Permit: 2,010.00
Plan : 1,306.50
Paid $1,028.46 5-15-97
S. Archuleta
Clerk
/7C-e3,/c-, F7 /
Applicant to complete numbered spaces only. PERMIT NO. C.JJ33a2, PARCEUSCHED NO.
BUILDING PERMIT APPLICATION
GARFIELD COUNTY, COLORADO
JOB ADDRESs . 0/ 0 t2 5 le iT% 6/ ler,-J
.
ale!
9r
IV,oC..
23.i
frii
Vis ,
1 .
LEGAL
DESCR.
LOT NO. _
I
BLOCK
SUBDIVISION - I
A5(�a4 r r (JAI&
NG.
2
OWNER ASM tub ess A(C.
r,`v�,1,-�N
ADDRESS c( -fi ,i6EgJa.G• CJMboWiACH.
9435540
WK. PH.
3
CONTRACTORr'
/14 m 8o, jTr,R S .,lac..
010 sg.r a u �� •
ADDRESSG°rrU3oN � A..c Ca .
PH.
% 35 '�
LICENSE NO.
4
ARCHITECT OR DESIGNER W of SA a
LIQ`
ADDRESS �a {jS ea a t(,'�.
PH. 41). 4 r r4 1
LICENSE NO.
5
ENGINEER �+L�rtR-
ADDRESS 4(� MAIN sr� 5�Na If
��r1�ci�r,>hck �•.
PH. gf.5�123
LICENSE NO.
6
�"��'-'_�6s�
2 Ki•�r gg„ if7 UI`G
F BUILD
S.F OF LOT
13000 S.F.
HEIGHT
A.
NO. OF
t
USE OF BUILDING p1A/#' Lrvr'r. p �E"�t/'
5c6t(r �(. graI R Cc G*0Pr
3gf ?•0. w
?cc- tz
8
HS71r:Nr vNIr�N�s�.y
8
Cuss of WORN: �EW ❑ ADDTION ❑ALTERATION ❑ REPAIR ❑ MOVE ❑ REMOVE R9 , t Spar
p•J5 d'1 =
15 4 C C." :
9
DESCRIBE WORK: 6 C4 L e r1 +tU ' WAG tl of FLIT . SI, f i N Y `4 ,d f
t4rc. I
' P S;arsy, vwirzttii�
.21..., .e2 =
I 10
GARAGE 4/ SINGLE UBL 1CARPORT SINGLE DOUBLE
'` ifeilivoriot, i '
3a2-
_'Y
%
DRIVEWAY PERMIT ON SITE SEWAGE DISPOSAL PERMIT SITE PLAN
"3I
'3 / (� ,50
0-
is•
VALUATION OF WORK: 5.275 OCQ ADJUSTED VAL.S 312, '/1, 09
PLAN CHECK FEE °�rJC
311
PERMIT FEE 21010.—
SPECIAL CONDITIONS. 37 i ,,0- X t4.
ley I'X 17
�r ' '
�" 3�
Y-2
C
(r- ez)
SCHOOL IMPACT FEE
NO. OF BUILDINGS
PARCEL
ON/
!
USE OF BUILDINGS NOW ON
PARCEL
9)4I
�}
OCC. GR(�-3
0- 1
CONST. TYPE 1"
f 3t'f y7G1,
TOTAL FE/
NOTICE
SEPARATE PERMITS ARE REDUIRED FOR ELECTRICAL PLUMBING,
VENTILATING OR AIR CONDITIONING.
THIS PERMIT BECOMES NULL AND VCiD IF WORK OR CONSTRUCTION AUTHORIZED
NOT COMMENCED WITHIN 160 DAYS, OR IF CONSTRUCTION OR WORK IS SUSPENDED
OR ABANDONED FOR A PERIOD OF 160 DAYS AT ANY TIME AFTER
COMMENCED
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND
THE SAME TO BE TRUE AND CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES
GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED
HEREIN CR NOT THE GRANTING DF A PERMIT DOES NOT PRESUME
AUTHO. TO V1CLATE CR CANCEL THE PROVISIONS OF AN •THER STATE
LO -T REGULATING CCNSTRUCTI0N O- PE, RMANCE
CONS •N
�' ���4rir .. 8) �/•
WATER SUPPLY
DATE PERMIT
ISSUED 14~/II" - 97
HEATING.
.SPCLALAFPROVALS
REQUIRE,
RECEIVED RECENS3
NOT SECURED
IS
WORK IS
KNOW
TO GIVE
OR
OF
ZONING
i'' -
HEALTH DEPT.
FIRE DEPT.
SOIL REPORT
SETBACKS
��
/
FLOOD HAZARD
�r�flPd
5 ria cto • gen awl .'eadan• . , e;;�,.• nci-.- a•.ve.
�`,f. r ' �
MANUF HOME
AW
BUllcmg Deperrment ADprovalda /'�v/77 ^tanning Departrn- Appro . •
OTHER
AGREEMENT
PERMISSION IS HEREBY GRANTED TO THE APPLICANT AS OWNER, CONTRACTOR AND/OR THE AGENT OF THE CONTRACTOR OR OWNER TO
CONSTRUCT THE STRUCTURE AS DETAILED ON PLANS AND SPECIFICATIONS SUBMITTED TO AND REVIEWED BY THE BUILDING DEPARTMENT
32
.1
z a
!N CONSIDERATION OF THE ISSUANCE OF THIS PERMIT THE SIGNER HEREBY AGREES TO COMPLY WITH ALL BUILDING CODES AND LAND USE
REGULATIONS ADOPTED BY GARFIELD COUNTY PURSUANT TO AUTHORITY GIVEN IN 30.28.201 CRS AS AMENDED. THE SIGNER FURTHER
.AGREES THAT IF THE ABOVE SAID ORDINANCES ARE NOT FULLY COMPLIED WITH IN THE LOCATION, ERECTION, CONSTRUCTION AND USE OF
THE ABOVE DESCRIBED STRUCTURE. THE PERMIT MAY THEN BE REVOKED BY NOTICE FROM THE COUNTY AND THAT THEN AND THERE IT
SHALL BECOME NULL AND VOID.
THE ISSUANCE OF A PERMIT BASED UPON PLANS, SPECIFICATIONS AND OTHER DATA SHALL NOT PREVENT THE BUILDING OFFICIAL FROM
THEREAFTER REQUIRING THE CORRECTION OF ERRORS IN SAID PLANS, SPECIFICATIONS AND OTHER DATA OR FROM PREVENTING BUILDING
CPERATION BEING CARRIED ON THEREUNDER WHEN IN VIOLATION OF THIS CODE OR ANY OTHER ORDINANCE OR REGULATION OF THIS
JURISDICTION.
THE REVIEW OF THE SUBMITTED PLANS AND SPECIFICATIONS AND INSPECTIONS CONDUCTED THEREAFTER DOES NOT CONSTITUTE AN
ACCEPTANCE OF ANY RESPONSIBILITIES OR LIABILITIES BY GARRELD COUNTY FOR ERRORS, OMISSIONS OR DISCREPANCIES. THE
RESPONSIBILITY FOR THESE ITEMS AND IMPLEMENTATION DURING CONSTRUCTION RESTS SPECIFICALLY WITH THE ARCHITECT, DESIGNER,
BUILDER AND OWNER- COMMENTS ARE INTENDED TO BE CONSERVATIVE AND IN SUPPORT OF THE OWNERS INTEREST.
Garform.003 I HEREBY ACKNOWLEDGE THAT I HAVE READ AND UNDERSTAND. THE AGREEMENT ABOVE 1INITIAL BL
The following items are required by Garfield County for a final inspection:
1. A final Electrical Inspection from the Colorado State. Electrical Inspector;
2. Permanent address assigned by Garfield County Building Department posted where'readily
visible from access road;
3. A finished roof, a lockable house, complete exterior siding, exterior doors and windows
installed, a complete kitchen with .cabinets, a'sink with hot & cold running water, non-absorbent
. kitchen floor coverings,, counter tops and finished walls, ready for stove and refrigerator, all
necessary plumbing.; .
4. A complete;bathroorim, with wash bowl, tub or shower: toilet stool_ hot and coid running-
water,
unningwater, non-absorbent floors and walls finished and a privacy door;
5. All teps outside or.in*ide over three (3) steps must have handrails, guard rails on balconies or
decks over 30" high constructed to all 1994 UBC requirements.;
O. Outside grading done to where water will detour away from the building;
- 7. Exceptions to the outside steps. decks and grading. may be made upon the demonstration of
etenuating circumstances. i.e. weather. but a Certificate of Occupancy will not be issued until all
the required items are completed and a final inspection made.
A CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL ALL THE ABOVE
ITEMS HAVE BEEN COMPLETED.
*"*Cannot occupy or use dwellin2 until a Certificate of Occupancy (C.O.) is issued.
Occupancy or use of dwelling. without a C 0 will be considered an illegal occupancy and may be
grounds for vacating premises until above conditions are met
I understand and agree to abide by the above conditions for occupancy, u e and the issuance of a
Cer ficate • Occupancy for the dwelling. under building. permit .— i - (33;_
11 4,„...k.T. s 5- 9/
wd Date
GARFIELD COUNTY BUILDING AND PLANNING
970-945-8212
MINIMUM APPLICATION REQUIREMENTS
for
SINGLE FAMILY DWELLING CONSTRUCTION
including
NEW CONSTRUCTION
MANUFACTURED. HOMES
ADDITIONS
ALTERATIONS
and
MOVED BUILDINGS
In order to understand the scope of the work intended under a permit application and expedite
the issuance of a perrnit it is important that complete information be provided. Adequate and
complete information will prevent delays in the plan review process. Reviewing a plan and the
discovery that required information has not been provided by the applicant may result in the
delay of the permit issuance and m proceeding with building construction. The owner or
contractor may be required to provide this information before the plan review may proceed. This
causes delays because other plans that are in line for review may be given attention before the
new information may be reviewed after it has been provided to the Building Department.
Please review this document to determine if you have enough information to design your
project and provide adequate information to facilitate a plan review. if you do not, it may
be helpful to obtain a book titled "Dwelling Construction under the Uniform Building
Code". This book is available to you through this department at our cost. Also, please
consider using a design professional for assistance in your design and a construction
professional for construction of your project.
To provide for a more understandable plan in order to determine compliance with the building,
plumbing and mechanical codes, applicants are requested to review the following check list prior
to and during design. Applicants are require to indicate appropriately and to submit the
completed check list at time of application for a permit.
For the placement of a manufactured home, questions numbers 1-4 and 19-28 are the only
questions that need to be addressed:
1
1. Is a site plan included that indicates the distances of the proposed building or addition to property
lines, otheuildings, set back easements and utility easements?
Yes �V
Does the site plan include the location of the I. S.D. S. (Individual Sewage Disposal System) and
the distances to property lines, wells (on subject property and adjacent properties), streams or
water cour s?
Yes
Does the site plan indicate the location and direction of the County or private road accessing the
property? j
Yes ✓
4. Do the plans include a foundation plan indicating the size, location and spacing of all reinforcing
steel in ac rdance with the uniform building code or per stamped engineered design?
Yes
5. Do the plans indicate the location and size of ventilation openings for under floor crawl spaces and
the clears required between wood and earth?
Yes
6. Do the plans indicate the size and location of ventilation openings for the attic, roof joist spaces
and soffits?/
Yes �/
7. Do the plans include design loads as required under the Uniform Building Code for roof snow
loads, (a rrmum of 40 pounds per square foot in Garfield County), floor loads and wind loads?
Yes
Does the plan include a building section drawing indicating foundation, wall, floor and roof
construct. n?
Yes
Does the building section drawing include size and spacing of floor joists, wall studs, ceiling joists,
roof rafter or joists or trusses?
Yes
10. Does the buildin section drawing or other detail include the method of positive connection of all
columns and eams?
Yes
2
11. Does the plan indicate the height of the building or proposed addition from the highest point of
the building or addition measured at mid span between the ridge and the cave down to existing
grade coy's?
Yes
12, Does the plan include any stove or zero clearance fireplace planned for installation including make
and mode nd Colorado Phase II certifications or phase II EPA certification?
Yes No _. /"OT f PI4S7% /L e4-‘940 a ry
11 Does the plan include a masonry fire lace including a fireplace section indicating design to comply
with the Uniform Building Cod hapter 37?
Yes No
14. Does the plan include a window schedule or other verification that egress/rescue windows from
sleeping ro ms and/or basements comply with the requirements of the Uniform Building Code?
Yes No
15. Does the plan include a window schedule or other verification that windows provide natural light
and ventil on for all habitable rooms?
Yes No
16 Do the plans indicate the location of glazing subject to human impact such as glass doors, glazing
immediately adjacent to such doors; glazing adjacent to any surface normally used as a walking
surface; sliding glass doors; fixed glass panels; shower doors and tub enclosures and specify safety
glazing for ese areas?
Yes No
17. Is the location of all natural and liquid petroleum gas furnaces, boilers and water heaters indicated
on the plar,`�
Yes �V' No
18. Do you understand that if you belong to a homeowners association, it is your responsibility to
obtain written rmission fro the association, if required by that association, prior to submitting
an applicati for a building permit?
Yes No
19. Will this,'e the only residential structure on the parcel?
Yes ✓✓ No If no -Explain:
20. Have two {^ complete sets of construction drawings been submitted with the application?
Yes
3
21. Is this an application for the plac ent of a manufactured home?
Yes No
If yes, have you specified the size of the unit (min. 20ft. x 20ft); Jive roof load (min. 40#); wind
design (min. wind speed of 80 mph & 15 lb. wind load); foundation design; method of anchoring?
Yes
22. Have you de igned or had this plan designed while considering building and other construction
code requi ments?
Yes No
23. Does the pi n accurately indicate what you intend to construct and what will receive a final
inspection y the Garfield County Building Department?
Yes No
24. Do you understand that approval for design and/or construction changes are required prior to the
application of these changes?
Yes L/ No
25. Do you understand that the Building Department will collect a "Plan Review" fee from you at the
time of appli tion and that you will be required to pay the "Permit Fee" as well as any "School
Impact" o eptic System" fees required, at the time you pick up your building permit?
Yes No
26. Are you aware that twenty four (24) hour notice is required for all inspections? Inspections
will be made from Battlement Mesa to West Glenwood in the mornings and from Glenwood
Springs to Carbondale in the afternoon. Morning inspections must be called in by 12:00
p.m. the day before; afternoon inspections must be called in by 5:00 p.m. the day before.
Failure to gi a twenty four (24) hour notice for inspections will delay your inspection one
(1) day?
Yes No
27. Are you aware that you are required to call for all irispections required under the Uniform Building
Code includi g approval on a final inspection prior to receiving a Certificate of Occupancy and
occupanc of the building?
Yes No
28. Are you aware that the person signing the Permit Application, whether the "Owner", "Agent of
the Owner" "General Contractor", "Contractor" or otherwise, is the party responsible for the
project c plying with the Uniform Building Code?
Yes No
4
1. hereby acknowledge that I have read, understand and answered these questions to the best of my
ability.
EA/ /41314VA-Tey
A 4 4 Sul c..Osiod Zsec, date
Phone: 963 Seek (days); 928 1 4 (evenings)
Project Name: 5(dart et,V /ZSIi1 r.4at Zor 6-- —/ 4 sfiet"
Project Address: XK)c$ I,t.~l15 6A -NE
Notes:
If you have answered "No" on any of the questions, you may be required to provide this information at the request of the Building
Official prior to beginning the plan review process. Delays in issuing the permit are to be expected. Work may not proceed
without the issuance of a permit. If it is determined by the Building Official that additional information is necessary to review
the application and plans to determine minimum compliance with the adopted codes; the application may be placed behind more
recent applications for building permits in the review process and not reviewed until required information has been provided and
the application rotates again to first position for review, delay in issuance of the permit or delay in proceeding with constructiou.
PerApp02.95 Effective August 15, 1995
5
INSPECTION WILL NOT BE MADE UNLESS
THIS CARD IS POSTED ON THE JOB
24 HOURS NOTICE REQUIRED FOR INSPECTIONS
i
BUILDING PERMIT
G RFIELD COUNTY, COLORADO
Date Issued . .......Zoned Area Permit No. ..4•33.
AGREEMENT
In consideration of the issuance of this permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location; construction and erection of the proposed
structure for which this permit is granted, and further agrees that if the above said regulations
are not fully complied with in the zoning, location, erection and construction of the above
describe structure, the permit may then be revoked by notice from the County Building
Inspe a DIME IATjELY : E e +j E NULL ANDS fV ID.
Us14,60.0
Ik) • ern�-�R/ i
This Card Must Be Posted So It is Plainly Visible From The Street Until Final Inspection.
INSPECTION RECORD
Footing 4. -4-577 ,1,mks7'CT' A R . 1-i —q2 /----;.-(-
FoundationL -„c-g l Al.,: u. ,„mac.,,,
Ciraafr,Ea 7 -16 7 rC -L .
s� Fail G-., 44-4. -
Underground Plumbing (o -.5c,677,—i,
Insulation j a _./_,7-i 1 �./
Rough Plumbing fo — .57 f
Drywall i _ z y , i i I!
Chimney & Vent -- -9 y
Electric Final (by State Inspector) 3-25---9/ 5/
Gas Piping / _, 3 _Gip .4, ,;
Final„,,,4_,.,74._e,-/-
Electric Rough (By State Inspector)/1_1C-fic
Septic Final 4, .
Framing iD -g3 -,1 4_,2„.......
(To include Roof in place and Windows
and Doors installed).
Notes: •
rnr PIP-6'6'P”/M �r �- �? � '�
ALL LISTED ITEMS MUST BE INSPECTED AND APPROVED BEFORE COVERING -
WHETHER INTERIOR OR EXTERIOR, UNDERGROUND OR ABOVE GROUND.
THIS PERMIT IS NOT TRANSFERABLE
Phone 945-8212 109 8th Street County Courthouse Glenwood Springs, Colorado.
APPROVEDDO NOT DESTROY THIS CARD
Date By f
I PLACED OUTSIDE - OVER WITH CLEAR PLASTIC