Loading...
HomeMy WebLinkAbout1.0 ApplicationFox Engineering Solutions, Inc. P.O. Box 413, Fruita CO 81521 Ph: (970) 250-5505 Email: coloradofox@bresnan.net Inspection Report for: GM 34-14 Well Pad - Small Temporary Employee Housing Prepare for: Terra Energy Partners Location: SW1/4 SE1/4 of Section 14, T7S, R96W, 6th P.M. Garfield County Conducted By: David Fox, P.E. Date Conducted: April 8, 2019 Garfield County Paragraph Article 7-707 Land Use& Development Code (7/15/13) Reference Characteristic or Standard Description Inspection Comments A.Within 48 hours following occupation of the Small Facility, documentation shall be provided to the Community Development Department, Sheriff’s Office, and relevant fire protection district(s) that demonstrates and certifies compliance with the following standards. Notice shall also be provided to these entities within 48-hours following removal of a Small Facility. Not subject to visual inspection and certification by third party Professional Engineer. B.General Information reguirements Not subject to visual inspection and certification by third party Professional Engineer. C.Small Facilities shall comply with all applicable Federal, State (i.e. Building Codes and electrical permits), and local laws and regulations (i.e. fire code), but are not subject to County Building Permit. Colorado Division of Housing certifications noted on Company Office trailer, Unit ID. AJGO-1457-3773 with Certification No. 18636 manufactured by Advanced Modular Mfg. in 2007; Company trailer, Unit ID D1460129803 with Certification No. 25361 manufactured by PTI Group USA in 2012; Driller's trailer, Unit ID. 30-3319 with Certification No. 20534, manufactured by Ameritech Buildings in 2008; Directional trailer, Unit ID AAJU-1465- 4185 with Certification No. 23718 manufactured by Advanced Modular in 2010; and Mud Engineer trailer, Unit ID AABU-1465- 4531 with Certification No. 24893 , manufactured by Advanced Modular Mfg. in 2012. All other aspects not subject to visual inspection and certification by third party Professional Engineer. D Water systems shall comply with standards set forth in section 7-705.B. The water system at this location is not a public water system, as defined by the Colorado Department of Public Health & Environment - WQCC Regulation No. 11. It is not subject to State permitting requirements. Two potable water tanks with a capacity of approximately 3360 gallon each and equipped with water meters were located at the permitted site. Page 1 of 3 GM 34-14 Well Pad Inspection Terra Energy Partners Fox Engineering Solutions, Inc. April 8, 2019 E.Wastewater systems shall comply with standards set forth in section 7-705.C. Wastewater disposal at the permitted site will be a vault-and-haul system. Four 1500-gallon sewage holding tanks onsite. Sewage flows estimated to be 300 gallons/day (4 individuals x 75 gpcd). Sewage holding tanks need to be emptied approximately every 20 days (6000 gallons / 300 gallons per day). Wastewater vaults equipped with overflow alarm device. F.Each Small Facility shall be maintained in a clean, safe, and sanitary condition, free of weeds and refuse. Any hazardous or noxious materials that must be stored at the Small Facility for operational or security reasons must be managed in accordance with all applicable Federal, State, and local laws and regulations. Site appeared to be maintained in clean, safe and sanitary condition, free of weeds and refuse. G.Wildlife-proof refuse containers must be provided for trash. Outdoor food storage is prohibited unless facilities are provided that prevent the attraction of animals to the Major Facility site. One wildlife-proof trash recepacle with a capacity of approximately 20 cubic yards each onsite. Individual refuse containers in each office/housing structure. H.1 Provisions for giving alarm in case of fire and fire suppression must be installed per fire codes and as required by the fire protection district. Smoke detectors and fire extinguishers (ABC-rated) located in all factory built non-residential structures. Factory-Built Nonresidential Structures have a minimum separation distance of 20 ft. Approximately 10,000 gallons of water is stored onsite for fire suppression activities. Required fire suppression demand is 2500 gallons. Water meters and dry hydrant connections observed on water tanks. H.2 Single-station carbon monoxide alarms must be placed in each Manufactured Home or Recreational Vehicle unit. Single-station carbon monoxide detectors located in all factory built non-residential structures I.Domestic animals are prohibited. No domestic animals observed on-site. J.The Operator shall obtain a certification inspection conducted by a qualified professional engineer. The certification shall verify that at the time of inspection the identified Small Facility meets or exceeds the requirements of this section. This inspection was conducted by a qualified Professional Engineer licensed in Colorado and certifies compliance with applicable standards set forth in Article 7.707 of the Land Use and Development Code (7/15/13), as amended, that are subject to visual inspection. Page 2 of 3 GM 34-14 Well Pad Inspection Terra Energy Partners Fox Engineering Solutions, Inc. April 8, 2019 Professional Engineer's Attestation PE Certification Number: No. 25420 (Colorado)PE Stamp Date of Inspection: April 8, 2018 Print Name and Title: David J. Fox, Principal Engineer Signature: I hereby attest that I am a Licensed Professional Engineer in the State of Colorado. I attest that I or my agent have conducted a visual inspection of the Small Facility identified in this Checklist, as installed, and, based on information from that inspection I certify that the Small Facility complies with the standards, subject to and limited to visual inspections items as identified above; set forth in Article 7-707 of the Land Use& Development Code (Effective 7/15/13), for Garfield County, Colorado. Page 3 of 3 Notes: The well pad site is located in the SW 1/4 SE 1/4 Section 14,T7S , R96W , 6th P.M. (NAD83 N39.4328o W108.0749o) The site will temporarily office and house up to a maximum of eight individuals during natural gas drilling activities and is expected to be completed in one year or less. The individuals will occupy four individual trailer houses located on the well pad. Trailer houses have Colorado Division of Housing compliance tags. Aboveground sewage holding tanks with aggregate storage of 6000 gallons capacity on-site. Sewage flows estimated to be 600 gallons/ day (8 individuals x 75 gpcd). Sewage holding tank needs to be emptied approximately every 10 days (6000 gallons / 600 gallons per day). Wastewater vaults equipped with overflow alarm devices. Terra utilizes the services of a licensed contractor to remove and haul the wastewater to a State certified treatment/disposal facility. Potable aboveground water tanks with aggregate storage of 6720 gallons capacity on-site. Potable water demand is estimated to be 600 gallons/day (8 individuals x 75 gpcd). Required minimum fire suppression demand is 2500 gallons. 10,000 gallons of water are stored onsite for fire suppression activities. Dry hydrants and water meters were on potable water tanks. Road access to the site is maintained year-round through the services of private road maintenance and construction contractors. Base mapping by Bookcliff Survey Services. Site features including housing trailers, water and wastewater tanks, portable toilets and dumpster were field located. Please note that this is a construction site and that the locations of drill equipment and other items are subject to change. Factory-Built Nonresidential Structures (/Housing) have a minimum separation distance of 20 ft. Terra Energy Partners,LLC GM 34-14 Well Pad GM 34-14 Site Plan Garfield County, Colorado Small Temporary Employee Housing and Septic Permit Application Applicant: Terra Energy Partners,LLC Date: April 8, 2019 Checked:DJF Version: 001 Fox Engineering Solutions, Inc. P.O. Box 413,Fruita, CO 81521 Ph: (970) 250-5505 Email:coloradofox@bresnan.net Directions to Site: Emergency Contact List: Main Office: (970) 285-9377 answered 24 Hours Lynn Cass: Drilling Sup (970) 755-0083 Cell Mark Mewshaw : Drilling & Completions Manager (304) 612-7844 Cell Kevin McDermott: Safety (970) 309-1195 Cell Mike Gardner: Spill Response (970) 623-4873 Cell Identification & Location Key* 1. Wastewater Aboveground Tank (1500 gal.) 2. Potable Water Aboveground Tank 3320 gal) 3.Portable Toilets 4.Wildlife-proof dumpster 5. Company Man Housing 6. Office 7. Driller's Office/Housing 8. Directional 9. Mud Engineer 10. Shed * Subject to relocation for construction activities. 18 5 3 6 1 10 23 ft. 9 12 7 20 ft. 10 10 4 12 50 ft. TEP Rocky Mountain LLC 1058 County Road 215 P.O. Box 370 Parachute, Colorado 81635 (970) 285-9377 April 8, 2019 Garfield County Sheriff’s Office Emergency Operations Attn: Chris Bornholdt 107 8th Street Glenwood Springs, CO 81601 Ph: 970-945-0453 RE: Emergency Response Notification GM 34-14 pad (Lat.: 39.432893 Long.: -108.074900) This notification is to inform the Garfield County Sheriff’s Office that TEP Rocky Mountain LLC has commenced drilling operations on the above mentioned location. TEP will provide rig site housing accommodations for the duration of the operations which will be approximately 40 days. In accordance with Garfield County Community Development we must notify you of the small temporary employee housing onsite. Please see the provided emergency response information, site layout and directions to location. Should you have any questions or concerns regarding this notification please feel free to contact me. Sincerely, Kaylee McIntosh | Engineering Technician | TEP Rocky Mountain LLC | 1058 County Road 215 | Parachute, CO 81635  (Office) 970.263.2731 |  (Mobile) 970.623.9452 |  kmcintosh@terraep.com TEP Rocky Mountain LLC 1058 County Road 215 P.O. Box 370 Parachute, Colorado 81635 (970) 285-9377 April 8, 2019 Grand Valley Fire Protection District Emergency Operations Attn: Deputy Fire Chief Rob Ferguson 0124 Stone Quarry Rd Parachute, CO 81635 Ph: 970-285-9119 RE: Emergency Response Notification GM 34-14 pad (Lat.: 39.432893 Long.: -108.074900) This notification is to informthe Grand Valley Fire Protection District that TEP Rocky Mountain LLC has commenced drilling operations on the above mentioned location. TEP will provide rig site housing accommodations for the duration of the operations which will be approximately 40 days. In accordance with Garfield County Community Development we must notify you of the small temporary employee housing onsite. Please see the provided emergency response information, site layout and directions to location. Should you have any questions or concerns regarding this notification please feel free to contact me. Sincerely, Kaylee McIntosh | Engineering Technician | TEP Rocky Mountain LLC | 1058 County Road 215 | Parachute, CO 81635  (Office) 970.263.2731 |  (Mobile) 970.623.9452 |  kmcintosh@terraep.com