HomeMy WebLinkAboutOWTS Installation Observations 05.11.19 May 11, 2019 Project No. C1348 Robbie Levin robbie@leafpeople.com Onsite Wastewater Treatment System (OWTS) Installation Observations Lot 15 Ranch at Coulter Creek 778 Cattle Creek Ridge Road Garfield County, Colorado Permit Number SEPT-18-5176 Robbie, ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on August 30, 2018 and May 10, 2019 for the subject property. Ryan Ivy installed the system. The system installation included a 1500-gallon, two-compartment Valley Precast concrete septic tank with an Orenco® ProPak pumping system and PF3005 pump in the second compartment of the septic tank. The effluent filter in the second compartment must be cleaned annually, or as needed. The floats were set to dose approximately 80 gallons each pump cycle, allowing for approximately 5 gallons of drain back into the septic tank after each pump cycle. This will result in a dose to the field of approximately 75 gallons each pump cycle. Risers were installed on the septic tank to bring access to grade. Handle extensions on both the effluent filter and float tree must be installed if the riser height exceeds 1-foot. The control panel was located within line of sight of the septic tank. Valley Precast out of Buena Vista performed start up on the pumping system. A 1.5-inch diameter Schedule 40 pump was installed from the pump to an Orenco® automatic distributing valve (ADV), model 6605. The ADV was placed a high point in the system in an insulated riser with access from grade. Screened rock was placed below the ADV to support the ADV and to assure the clear pipes exiting the ADV remain visible for future inspection and maintenance. Effluent is pressure dosed through 1.5-inch diameter pipes to five trenches, each with 17 ‘Quick 4’ Standard Plus Infiltrator® chambers, for a total of 85 chambers and 1020 square feet of infiltrative area. There was at least 6-feet of undisturbed soil between each trench. Effluent is pressure dosed to 1.5-inch diameter laterals, which were hung with zip ties from the underside of the chambers. Laterals have 5/32- inch diameter orifices facing up, with the exception of the first and last holes facing down for drainage. The orifices were drilled 3-feet on center. Each lateral ends in a 90 degree ell facing up with a ball valve for flushing. Valves were placed in a valve box, accessible from grade, for access. Inspection ports were placed at the beginning and end of each trench. Ports may be cut to grade and covered with a valve box for access. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection . The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed By: Carla Ostberg, MPH, REHS Richard H. Petz, P Photos August 30, 2108 End of trench view of septic tank from soil treatment area (STA) 5/12/19 Septic tank prior to backfill View of trench Trench flushing valve and inspection port Flushing valve May 10, 2019 View of STA Automatic distributing valve ADV (needs more gravel) view of septic tank lids Control panel counter (black) – track counts at 75 gallons per pump cycle Clean out (needs cap) Pump Selection for a Pressurized System - Single Family Residence Project Levin Parameters Discharge Assembly Size Transport Length Before Valve Transport Pipe Class Transport Line Size Distributing Valve Model Transport Length After Valve Transport Pipe Class Transport Pipe Size Max Elevation Lift Manifold Length Manifold Pipe Class Manifold Pipe Size Number of Laterals per Cell Lateral Length Lateral Pipe Class Lateral Pipe Size Orifice Size Orifice Spacing Residual Head Flow Meter 'Add-on' Friction Losses 1.25 42 40 1.50 6605 60 40 1.50 5 0 40 1.50 5 70 40 1.50 5/32 3 5 None 0 inches feet inches feet inches feet feet inches feet inches inches feet feet inches feet Calculations Minimum Flow Rate per Orifice Number of Orifices per Zone Total Flow Rate per Zone Number of Laterals per Zone % Flow Differential 1st/Last Orifice Transport Velocity Before Valve Transport Velocity After Valve 0.68 24 16.4 1 3.9 2.6 2.6 gpm gpm % fps fps Frictional Head Losses Loss through Discharge Loss in Transport Before Valve Loss through Valve Loss in Transport after Valve Loss in Manifold Loss in Laterals Loss through Flowmeter 'Add-on' Friction Losses 1.9 0.7 5.8 1.0 0.0 0.5 0.0 0.0 feet feet feet feet feet feet feet feet Pipe Volumes Vol of Transport Line Before Valve Vol of Transport Line After Valve Vol of Manifold Vol of Laterals per Zone Total Vol Before Valve Total Vol After Valve 4.4 6.3 0.0 7.4 4.4 13.7 gals gals gals gals gals gals Minimum Pump Requirements Design Flow Rate Total Dynamic Head 16.4 19.8 gpm feet 0 5 10 15 20 25 30 35 40 0 50 100 150 200 250 300 Net Discharge (gpm) PumpData PF3005 High Head Effluent Pump 30 GPM, 1/2HP 115/230V 1Ø 60Hz, 200V 3Ø 60Hz PF3007 High Head Effluent Pump 30 GPM, 3/4HP 230V 1Ø 60Hz, 200/460V 3Ø 60Hz PF3010 High Head Effluent Pump 30 GPM, 1HP 230V 1Ø 60Hz, 200/460V 3Ø 60Hz PF3015 High Head Effluent Pump 30 GPM, 1-1/2HP 230V 1Ø 60Hz, 200/230/460V 3Ø 60Hz Legend System Curve: Pump Curve: Pump Optimal Range: Operating Point: Design Point: 832‐R‐13‐002