HomeMy WebLinkAboutCorrection Notice 06.05.2019Garfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Phone (970) 945-8212
PERMIT #5376
CORRECTION
NOTICE
Project Address 7004 cr 312
Call for re -inspection.
fl$50.00 re -inspection fee must be paid prior to re -inspections.
I have inspected this work and have found the following corrections are required:
Dryer vent to be solid pipe not flex
Truss drawings to be on site
Add drywall backing and strike protection of gas pipe
Secure king stud to header 3/8" gap to be filled
Sister stud in m bathroom north wall were blown out
Add plate anchor m bath
Add backer flashing at siding joints or face flashing
Add z flashing above windows above trimq
Add mechanical ventilation in mechanical room unless using electrical units
Inspected by: Matt M Provost Date 6/4/19
YOU ARE HEREBY NOTIFIED THAT THE ABOVE CORRECTION
MUST BE INSPECTED BEFORE COVERING.
When corrections have been made, please call for a new
inspection. 970-945-1377 x 1621