HomeMy WebLinkAboutEngineer's Report on Retaining Wall 04.11.2019rFR S 1.1111CHOLS 4055 International Plaza, Suite 200 • Fort Worth, Texas 76109 • 817-735-7300 • fax 817-735-7491 April 11, 2019 Garfield County Building Inspections 108 8th St. Ste. 401 Glenwood Springs, CO 81601 Re: Retaining Wall for Dollar General Store in Parachute, CO To whom it may concern, innovative approaches recticai results Outstanding service www.freese.com I am the Engineer of Record for the Dollar General Store located Stone Quarry Road in Parachute, Colorado. I have reviewed the Testing Lab Report and the progress photos of the concrete footings of the retaining wall associated with this facility. (See attached.) Please note that the concrete testing results are for 7 -day breaks only and 28 -day testing will be available until April 25, 2019. It is my understanding that there are no other unresolved construction issues associated with the wall. On this basis and with the exception of the concrete strength, it is my understanding that the wall has been constructed in conformance with our original design intent. Once the 28 -day concrete compressive strength results are known and assuming the compressive strength is at least 4,000 psi, the construction should be considered satisfactory. Given that the 7 -day compressive strengths were over 3,700 psi, we anticipate that the 28 -day strength will be in excess of that required. If you have any questions, please let me know. Sincerely, Brad Watson, P.E. Structural Engineer Freese & Nichols, Inc. 4055 International Plaza, Suite 200 Fort Worth, TX 76109 bbw@freese.com 817-735-7416 04/11/2019 41014E44)1k4-4-7r- 51 4( 1::4+r.�it1"'�-i 1, C:* l p da, yr . Ee�lneue ® CE CONTRACTION JOINTS.ua. ,UM SPACING 0 CON7RpCnN .JOINT DETAIL >c�v.+...o.. ,217.5 OASE OF WALL DETAIL AT EXPANSION JOINT FF OFWAuATFTG 1NpcUJG FA ka_/lroc me, O, FOOTING AT STEP W/O CONTRACTION JOINT ▪ '1. * Ant.aa 1.7 trrn 1 _ ■kI.-1� vux•p•MIrrala kw* sSMOOTH EXPANSION JOINT DETAIL WO. ,c.m K.0 I • REINFORCING SHOWN APPLIES 10 ALL Hopnzonn-. was 0 CORNER REINFEIDETAIL SCALE' NOT TO SECTION THROUGH FOOTING ®BASE OF WALL DETAIL AT OONTRACTIONJJO FJT .o.v.- E011...• ft. CAL COMPACTED FILL CAST UNDISTU eBEDM x• Y WARMY111•4.1.4411.4.W. o Nocaruns sone. •.[oTE4.sR mom ma, *Peal a.'r"ara:}.uyy.. ame,.v...ma.n.n aw.m..a.w. v.obi..0,1401Tw'` 'r....,",.ee.w..Ei,.n PARLOR I. aw.... ®RETAINING. WALL SECTION ecac .r..,r IIETA.RIB WN17DE W!L E • BAR B AAA B.4.4 Env Ffi a..r 1 1' a.v ..r w.e .,..F v .r nev a�•r LIF 4 n..r ..v '4- 1•'7 .v Far Tar ...r ■.v '1'.'EITIALL NEM, "A' SHOWN IN SCHEDULE IS NIPSIAM1.4 HE.111" FOR TN, WALL TYPE ALTERNATE BAR A MTH BAR. FOR BAR SPACING OF 0 OC ALTERNATE BAR B WITH BAR 112 EVA SPACING OF FCC r- k g0 W <m Z o0 Z0 W W Z ,, 0Q2 NMI NQ E as L J