HomeMy WebLinkAboutOWTS Installation Observations 08.07.19
August 7, 2019 Project No. C1439
Jeramias Granados
Granadoslandscape@gmail.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
4812 CR 154
Garfield County, Colorado
Permit Number SEPT-04-19-5714
Jeremias,
ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS)
on April 24, 2019 for the subject property. Premier Landworks installed the system.
The existing septic tank was pumped, collapsed, and the void filled with onsite materials. The existing
soil treatment area (STA) was abandoned in place.
The system installation included a new sewer line, beginning just beyond the deck. The new, 4-inch
diameter SDR-35 sewer line was adapted to the existing cast iron line exiting the residence with a
Fernco. A new, 1500-gallon, 2-compartment Infiltrator® poly septic tank with an effluent filter on the
outlet tee was installed. This filter must be cleaned annually, or as needed.
Effluent gravity flows via a 4-inch diameter SDR-35 sewer line with a minimum 1% fall to a seepage pit.
The seepage pit was 14-feet long, 14-feet wide, and 10-feet deep below the inlet pipe. The bottom of the
excavation was filled with 6-inches of ¾-inch diameter cleaned screened rock. Four-foot diameter
perforated manhole rings were installed in the center of the seepage pit. Manhole rings were surrounded
by ¾-inch diameter cleaned screened rock.
An inspection port was installed in the southeast corner of the seepage pit. Access to the manhole rings
were brought to grade.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are
made to the OWTS in the future. Any additional OWTS construction must be according to the county
regulations.
LIMITS:
Observations are limited to components that are visible at the time of the inspection . The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
ALL SERVICE septic, LLC Reviewed By:
Carla Ostberg, MPH, REHS Richard H. Petz,
Clean out near residence 1500-gallon Infiltrator septic tank
Construction of seepage pit grade of sewer line
8/12/19
View from seepage pit toward driveway view of septic tank and seepage pit
Connection to existing cast iron pipe
Inlet tee outlet tee with effluent filter
Instructed handle extension on effluent filter
PERMIT CARD
POST THIS IN A CONSPICIOUS PLACE WHEN CONSTRUCTION IS STARTED
Project Address ____________________________________ Parcel No. ________________________
Owner Name _______________________________________ Owner Phone _____________________
Contractor(s) _______________________________________ Contractor Phone _________________
Work Description ______________________________________________________________________
AGREEMENT
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning,
location, construction and erection of the proposed structure for which this permit is granted. The applicant further agrees that if the above
said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit
may then be revoked by notice from the County Building division and immediately become null and void.
Inspection Comments Pass Date
Perc Test
Final
PLEASE SEE BACK OF PERMIT FOR OTHER COMMENTS
Permit Type ____________________________________
Work Classification _____________________________
Issue Date ___________ Expiration Date ___________
PERMIT #
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Phone (970) 945-8212
ADDITIONAL INSPECTIONS MAY BE REQUIRED
For Inspections Call (970) 945-1377 x1621
For Driveway Inspections Call (970) 625-8601
4/15/2020
replace existing tank and leach field that are failing.
Septic - ALT/ Repair
970-920-7832
OWNER
Jeremias Granados
SEPT-04-19-5714
239501200039
Repair
4/15/2019
4812 CR 154
832‐R‐13‐002