Loading...
HomeMy WebLinkAboutOWTS Installation Observations 08.07.19 August 7, 2019 Project No. C1439 Jeramias Granados Granadoslandscape@gmail.com Onsite Wastewater Treatment System (OWTS) Installation Observations 4812 CR 154 Garfield County, Colorado Permit Number SEPT-04-19-5714 Jeremias, ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on April 24, 2019 for the subject property. Premier Landworks installed the system. The existing septic tank was pumped, collapsed, and the void filled with onsite materials. The existing soil treatment area (STA) was abandoned in place. The system installation included a new sewer line, beginning just beyond the deck. The new, 4-inch diameter SDR-35 sewer line was adapted to the existing cast iron line exiting the residence with a Fernco. A new, 1500-gallon, 2-compartment Infiltrator® poly septic tank with an effluent filter on the outlet tee was installed. This filter must be cleaned annually, or as needed. Effluent gravity flows via a 4-inch diameter SDR-35 sewer line with a minimum 1% fall to a seepage pit. The seepage pit was 14-feet long, 14-feet wide, and 10-feet deep below the inlet pipe. The bottom of the excavation was filled with 6-inches of ¾-inch diameter cleaned screened rock. Four-foot diameter perforated manhole rings were installed in the center of the seepage pit. Manhole rings were surrounded by ¾-inch diameter cleaned screened rock. An inspection port was installed in the southeast corner of the seepage pit. Access to the manhole rings were brought to grade. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection . The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed By: Carla Ostberg, MPH, REHS Richard H. Petz, Clean out near residence 1500-gallon Infiltrator septic tank Construction of seepage pit grade of sewer line 8/12/19 View from seepage pit toward driveway view of septic tank and seepage pit Connection to existing cast iron pipe Inlet tee outlet tee with effluent filter Instructed handle extension on effluent filter PERMIT CARD POST THIS IN A CONSPICIOUS PLACE WHEN CONSTRUCTION IS STARTED Project Address ____________________________________ Parcel No. ________________________ Owner Name _______________________________________ Owner Phone _____________________ Contractor(s) _______________________________________ Contractor Phone _________________ Work Description ______________________________________________________________________ AGREEMENT In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed structure for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described structure, the permit may then be revoked by notice from the County Building division and immediately become null and void. Inspection Comments Pass Date Perc Test Final PLEASE SEE BACK OF PERMIT FOR OTHER COMMENTS Permit Type ____________________________________ Work Classification _____________________________ Issue Date ___________ Expiration Date ___________ PERMIT # Community Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 Phone (970) 945-8212 ADDITIONAL INSPECTIONS MAY BE REQUIRED For Inspections Call (970) 945-1377 x1621 For Driveway Inspections Call (970) 625-8601 4/15/2020 replace existing tank and leach field that are failing. Septic - ALT/ Repair 970-920-7832 OWNER Jeremias Granados SEPT-04-19-5714 239501200039 Repair 4/15/2019 4812 CR 154 832‐R‐13‐002