Loading...
HomeMy WebLinkAboutLetter from Engineer 04.01.2019Ernest Kollar Engineers, Inc. 320 Main St., Suite 203 Carbondale, CO 81623 Phone (970) 963-3223 erniekollar@gmail.com April 1, 2019 To: Steve Koski; Chris Martin Re: 405 Skipper Lane, Stirling Ranch, Carbondale, CO Steve/ Chris: This letter responds to recent building department inspection comments. 1. Sheet S.2.04 Upper Roof Framing, Gridline 7; One trimmer and one king stud is sufficient for the window header that was changed from a 9 ft opening to approximately 3 feet. 2. Sheet S.2.04 Upper Roof Framing, Gridline 7; The bathroom window was eliminated; therefore, the header shown may also be eliminated. 3. Sheet S.2.03 Upper Floor/ Lower Roof, between Grids 4 & 5.2 and D & E: Please see the attached repair detail (Sheet 1 of 5) for where the top joist flange was cut. 4. Sheet S.2.03 Upper Floor/ Lower Roof, near Grid E between 3 & 4 at skylights: Please see the attach repair detail (Sheet 2 Of 5) for the 5/8" diameter holes that were drilled too close to the joist bearing. In addition, the skylight framing was not shown on the structural drawings and the as -built framing was not coordinated with the engineer. Heading off joists for three rafter spaces results in a concentrated load that exceeds the capacity of the joists that flank each side of the skylights. Please see the attached plan revisions that correct the issue (Sheets 3-5 of 5). Thank you. Please call with any questions, &nest /Cot/4o Ernest Kollar, PE 4s-0" 4'—O" • • • • • • • • w ■ • • • • FLANGE NAILS 16d ® 4" O.C. CL CUT FLANGE 11 7/8" LVL x 8'-0" LONG CUT TOP FLANGE 1 1/2" WEB BACKER DAMAGED JOIST CUT JOIST FLANGE REPAIR Grids4&5.2andD&E Sheet 1 of 5 ERNEST KOLLAR ENGINEERS, INC. 320 MAIN STREET, SUITE 203 CARBONDALE, CO 81623 (970) 963-3223 phone erniekollar@gmail.com Brandon Residence 405 Skipper Lane Lot 7, Stirling Ranch Carbondale, CO Project No. Date: By: 1803 4/1/2019 EPK STEP 1 STEP 2 PLYWOOD/ OSB ON BOTH SIDE OF JOIST TO PACK WEB FLUSH WITH FLANGE (STEP 2) FASTEN WITH 8D NAILS 4" O.C. INTO EACH FLANGE 3/4 PLYWOOD/OSB (STEP 3) EXISTING I JOIST 12" RELOCATE AND ABANDON WIRES IN NO HOLE ZONE FASTEN W/ (4) 6d NAILS FASTEN WITH (2) ROWS OF 8D NAILS 4" O.C. INTO WEB DO NOT RECUT EXISTING HOLE THROUGH REPAIR REPAIR FOR HOLES TOO CLOSE TO BEARING Grid E between 3 8c 4 at skylights Sheet 2 of 5 ERNEST KOLLAR ENGINEERS, INC. 320 MAIN STREET, SUITE 203 CARBONDALE, CO 81623 (970) 963-3223 phone erniekollar@gmail.com Brandon Residence 405 Skipper Lane Lot 7, Stirling Ranch Carbondale, CO Project No. 1803 Date: 4/1/2019 By: EPK 2 3/8" 1--T-1 I NG: C OELEMil l;l J M N T.O.W. = 95'--6" T.O.F. = 90'-6" 2'-6" ). 8" 1 f 14'-6 7/8" VERIFY 8" 7 I .11 1 11 1 1 _—_J 7-9 1 /2" 8'-0 1 /4" 5 5.6.01 T.0 91 "TNG: G T.O.W. = 99'-8 1/4" T.O.F. = 95'-0" 0. 4'-0" k Skylight Framing — Foundation Grid E between 3 8c 4 at skylights Sheet 3of5 ERNEST KOLLAR ENGINEERS, INC. 320 MAIN STREET, SUITE 203 CARBONDALE, CO 81623 (970) 963-3223 phone erniekollar@gmail.com Brandon Residence 405 Skipper Lane Lot 7, Stirling Ranch Carbondale, CO Project No. 1803 Date: 4/1/2019 By: EPK Skylight Framing — Main Level Grid E between 3 & 4 at skylights Sheet 4 of 5 ERNEST KOLLAR ENGINEERS, INC. 320 MAIN STREET, SUITE 203 CARBONDALE, CO 81623 (970) 963-3223 phone erniekollar@gmail.com Brandon Residence 405 Skipper Lane Lot 7, Stirling Ranch Carbondale, CO Project Na 1803 Date: 4/1/2019 By: EPK 1/4" LVL h U O N n HNGR B L_ C EW BEAM • MAY BE LOCATED A ONG EDGE OF EXISTING YUGHT; ADJUST S "UCTURE BELOW HU11 TYP. 2x6 TAILS 4'-O" BACK SPAN W/ 2'-0" OVERHANG, TYP. 11 7/8" LVL LEDGER W/ (3) LEDGER LOK SCREWS 0 16" O.C. INTO STUDS BEAR OVER GRID E & F WALLS Skylight Framing — Lower Roof Grid E between 3 8c 4 at skylights Sheet 5 of 5 ERNEST KOLLAR ENGINEERS, INC. 320 MAIN STREET, SUITE 203 CARBONDALE, CO 81623 (970) 963-3223 phone erniekollar@gmaii.com Brandon Residence 405 Skipper Lane Lot 7, Stirling Ranch Carbondale, CO Project No. 1803 Date: 4/1/2019 By: EPK