Loading...
HomeMy WebLinkAboutEngineer's Letter of Installation 02.19.2018CIVIL ENGINEERING MEMORANDUM LAND SURVEYING To: Garfield County Building Division of the Community Development Department Matt Provost, Inspector From: Roger Neal, P.E. Date: February 19, 2018 Project: 2151036.00 — Cotton Hollow, Carbondale Subject: OWTS Construction Approval Letter Permit BLRE004-17-4671 The proposed OWTS field design for 200 Cotton Hollow Lane Carbondale, CO has been installed per the approved and permitted plans (Permit Number BLRE004-17-4671). The installation contractor was the owner. The bed was constructed per plan with 60 - ARC 36 chambers, a 1000 gallon polyethylene tank, distribution box and associated piping and cleanouts. The chambers were placed with between 1'-3' of cover from existing or proposed grade. Insulation was used above the pipe from the septic tank to the distribution box to accommodate shallow cover concerns. Cleanouts and Inspection ports were placed according to plan. The field is located in their general area of design as shown on the following page. The distribution pipes were placed per plan and can be seen in the attached pictures. The inspection ports that were installed were brought well above grade as shown by photos. Attached are photos of the installation. Please let me know if you have questions pertaining to this acceptance letter submittal. Thank you, High Country Engineering, Inc. ro 00 CIC�il • N., FR i !"'• , ob /a 29975 cri Roger Neal, P.E. ..a 2..�1 f 114* ``�t'���'r � 1517 Blake Avenue, Suite 101 Glenwood Springs, CO 81601 970-945-8676 • phone 970-945-2555 • fax www.hceng.com RVE ST Y GU I CLEAN OUT INV. 5-678,92' 'AY DISTRIBUTION BOX I NVS.=663$ 62' P-KUMAR PROFILE PIT 1 4'0 SOH -4 PVC ® 13.5% -.0 LEAN 0 INV.. 6684.92'`22 LF 4'0 SCH-40 PVC ® 15.5% 1,000 CALiON 2 CHAMRERNORWESCO BRUISER SEPTI TANK \ �\ \ \ \ \ \ \ \ \ OTTOM OF CH AMREkS=8676.00'`. TOP OF CHAMBERS=6806' MIN. TOP OF CROUND 6 ?9.10' MAX.. TOP OF GRGON0=66 3.06' \ \ v. \W/ BIO -FILTER I UTLET \ RIM: 5685.33'(W) \ ADS A \\ 66N5.33'(E) \ 6('X34"X1 \ TOP TANK- 6683.33' \ CHAMBER, N. \\ INV IN: 6682,55' \ UN ITS(TYP.) �\ I CUT:66.82..'T OTTTN TANK•6 R.50' 111:® \ \\ LEAN OUT \` , \ INV-: 6'689.57' , \ `\ \ \ ,1 \ \ \'ti. \ \ \ \ \ \ \ A \ \ 1 . APPROXIMATE SEWER CONNECTION INC OUT:6694.00' CLEAN CUT INV:6693.62. 4' 4 SOLID PIPE �F4�SPECTIC VEL (TW.) V°41 ENVELOP E PE B Field Completed in general location shown from Design REMOVABLE Pv0 GAF DRILL 4 - 1/2"0 AIR HOLES IN EXPOSED PIPE CUT HOLE IN TOP OF INFILTRATOR UNIT AT CENTER FOR INSTALLATION OF INSPECT1Cn WELL PIPE INFILTRATOR UNIT 4' • PERFORATED PIPE V INSPECTION WELL DETAIL N.T.S. 1 REMOVABLE PVC CAP INSTALL WARKER IF CAP IS TO OE ELRIE6. FINISH GRADE 4" COUPLING 4" 45' SHEEP HEW) 4" SEWER LINE 4" RISER x 4 x 4" PVC WYE CLEAN OUT ASSEMBLY SEWER CLEAN OUT DETAIL 1517 Blake Avenue, Suite 101 Glenwood Springs, CO 81601 970-945-8676 • phone 970-945-2555 • fax www.hceng.com N.T.S. As -Built of Field 1517 Blake Avenue, Suite 101 Glenwood Springs, CO 81601 970-945-8676 • phone 970-945-2555 • fax www.hceng.com Distribution Box and Pipes to Chambers Tank, Biofilter and Cleanout 1517 Blake Avenue, Suite 101 Glenwood Springs, CO 81601 970-945-8676 • phone 970-945-2555 • fax www.hceng.com Distribution box, and Inspection Ports. Chambers 1517 Blake Avenue, Suite 101 Glenwood Springs, CO 81601 970-945-8676 • phone 970-945-2555 • fax www.hceng.com Field Completion 1517 Blake Avenue, Suite 101 Glenwood Springs, CO 81601 970-945-8676 • phone 970-945-2555 • fax www.hceng.com