HomeMy WebLinkAboutEngineer's Foundation Design Clarifications 11.20.18M[()RAII() STRUOUßAI. . ENGINEERING SERVIGS. Bruce Barth Lot l/Filing 8 Garfield County, CO 1U20n8 RE: Zonakis Residence Bruce, Please see below for Foundation Clarifications for the Zonakis Residence,located in Garfield County, CO. l. Detait t - The typical footer is 10" tall x 24" wide reinforced with (2)-#5 cont. The dowels should be #5 @ 18" o.c. and may be wet-stabbed into the footer. 2. Detail 2 - The footer is 10" tall x24" wide reinforced with (2)-#5 cont. The dowels should be #5's @ 16" o.c. and may be wet-set into the footer. a. The Foundation wall along gridline 2 (between the garage and the house) will have the same footing as described above. However, the wall needs #5'shoiz. @ 12" o.c. located 2" ftomthe inside of wall (house side). 3. Detait 3 - Please reinforce the wall and footing as shown on the detail. The dowels may be wet-set into the footing. Please give me a call of you have any questions or need anything else. Sincerely, Mike Arbaney P.E. P.O. Box 2544 . Crested Butte CO 81224 USA ' ph:970'349.5922'l:970.349.5926