Loading...
HomeMy WebLinkAboutSpecial Inspector's Reports #1-4West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Report #1 Page 1 of 1 Dates:•6-12-18 & 6-13-18 Project: Ensign Residence Address: 683 Overlook Dr. Garfield County, CO Building Permit No: BLRE-08-17-4868 General Contractor: Thunder Construction Contractor that Performed Work: Sopris Steel Inspection of shop fabrication or field work at job site: Shop Report: Visually inspected shop welding at steel beams & columns piece marked 1C1, 3C2, 5C2, 5C3, 5C4, 6C1, 6C2, 6C3, 6C4, 7C1, 7C2, 7C3, 9B1, 9B2, 9B3, 10B1, 10B2, 10B3, and 11B1. The welding inspected above appeared to be in substantial conformance with the plans, and the quality requirements of the AWS D1.1 Structural Welding Code. Further inspections should be performed, as work progresses on the project. Douglas E. Young C Certification #5102224 to : l We ti 'ng 5pe 'alp, spector & Bo pec' : !Inspector ireproo tial Inspector Inspector/Technician: Douglas E Young ® Douglas E Young CWI 96070131 QC1 EXP. 7/1/2020 West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Report #2 Page 1 of 1 Date: 7-23-18 Project: Ensign Residence Address: 683 Overlook Dr. Garfield County, CO Building Permit No: BLRE-08-17-4868 General Contractor: Thunder Construction Contractor that Performed Work: Sopris Steel Inspection of shop fabrication or field work at job site: Shop Report: Visually inspected shop welding at steel beams & columns piece marked 12B1 (Qty2), 13B1, 14B1, 15B1, 1C2, 2C1, 2C2, 2C3, 3C1, and 12C1. The welding inspected above appeared to be in substantial conformance with the plans, and the quality requirements of the AWS D1.1 Structural Welding Code. Further inspections should be performed, as work progresses on the project. Inspector/Technician: Douglas E Young Douglas E. Young Ms Cer [Cabo5102, ctura Weldl g S , el 10 t tee! Bol • ng S Sp y -applied Fireproofing or 1 Inspector pecial Inspector Douglas E Young CWI 96070131 til QC1 EXP. 7/1/2020 West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Report #3 Page 1 of 1 Date: 7-30-18 Project: Ensign Residence Address: 683 Overlook Dr. Garfield County, CO Building Permit No: BLRE-08-17-4868 General Contractor: Thunder Construction Contractor that Performed Work: Sopris Steel Inspection of shop fabrication or field work at job site: Field Report: Visually inspected field welding completed to date at steel column bases/shafts to embed plates, and inspected high strength A325 bolting at steel beam & column connections upper level & roof framing. The onsite welding & high strength bolting inspected above appeared to be in substantial conformance with the plans, and the quality requirements of the AWS D1.1 Structural Welding Code & the AISC/RCSC Specification for high strength bolting. Further inspections should be performed on any retraining structural field welding and/or high strength bolting. Inspector/Technician: Douglas E Young Douglas E. Young C Certification #5102224 ctura1 Wei• g Specia Stee SE Hokin d rock ing S dor speetor 1Inspector Douglas E Young CWI 96070131 QC1 EXP. 7/1/2020 West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 Final Inspection Report Report #4 Page 1 of 1 Dates:.9-19-18 & 11-2-18 Project: Ensign Residence Address: 683 Overlook Dr. Garfield County, CO Building Permit No: BLRE-08-17-4868 General Contractor: Thunder Construction Contractor that Performed Work: Sopris Steel Inspection of shop fabrication or field work at job site: Field Report: Visually inspected field welding at column bases/screw jacks, field welded washer plates at column bases grid line E, field welding at the structural gluelam beam bearing plates/seats grid line E roof framing, field welding at column caps North dormer roof framing, and welding at column to tube steel beam connection angles North Shed roof framing. The onsite welding inspected above appeared to be in substantial conformance with the construction documents, and the quality requirements of the AWS D1.1 Structural Welding Code. To the best of my knowledge this completes the special inspections of the structural steel welding & high strength A325 bolting, as outlined in reports #1 thru #4 on the project. Inspector/Technician: Douglas E Young Douglas E. Young Certification #$,102224 cturj lying Spe & Bo ihepraofrn 1 We 1 Step =applied Douglas E Young CW 196070131 QC1 EXP. 7/1/2020 r nspector ial Inspector