Boiler #1 & Boiler #2
FTXL Job Name: Big Mountain Ranch Main House Address: 2147 Ute Stock Dr. START-UP City: Rifle OVERVIEW Retrofit New Project 0 How many units are installed at this location? Boiler(s): 2 Water Heater(s): 2 Inspect gas pipe, regulator and meter sizing. Is it sized correctly Ci y for the Btu/Hr requirement? D N $T: CO Zip: 81650 GAS SUPPLY Gas Pipe Dia, (in.): 1 Is there an inlet gas lockup regulator on the supply? If Yes, is it ten feet upstream from the appliance? • Y © N • Y • N Record in. of water column - Static Pressure: 12.5 Dynamic Pressure: 7.5 Comments/Corrections needed for gas supply, water or electricity: Water heaters-are--side--arrn-type----_- -_.... _- VENTING (Select the venting option being used): O Vertical Direct Vent - two pipe vertical termination O Common Vent - two or more units piped to the same flue O Horizontal Direct Vent - two pipe sidewall termination L,! Concentric Vent Vertical - single pipe vertical termination O Concentric Vent Horizontal - single pipe sidewall termination fl Vertical Vent w/ Sidewall Air - single pipe vertical termination w/ single pipe combustion air supply O Vertical Vent w/ Room Air - single pipe vertical termination • Horizontal Vent w/ Room Air - single pipe sidewall termination Heat Exchanger condensate piped to: Neutralizer Kit Q Drain Air Inlet Air Inlet Total Eqv. Dia. (in.): Material: Length (ft.): 4 Solid core Sch 40 PVC 30 Flue Dia. (in.): 4 Flue Material: Solid core Sch 40 PVC Total Eqv. Length (ft.): 30 Comments/Corrections needed for air inlet or vent piping: Send completed form to: Email: 2tech@Lochinvar.com Fax: (615) 882-2463 Mail: Service Dept/Lochinvar 300 Maddox Simpson Pkwy. Lebanon, TN 37090 CHECKLIST Model Number: FTX600N Serial Number: 1837 111885326 7-2-2019 Start-up Date: WATER & ELECTRICAL Water Pipe Dia (fit.): 2 At full fire, read and record - Inlet Temp: 120 Outlet Temp: 130 Delta T: 10 Supply VAC: 120 Ttl Amp draw: COMBUSTION Low Fire: 02 4.5 CO ppm 18 co, 10.1 High Fire: 02 CO ppm 5.2- 142 CO2 9.2 WARNING ! This Startup Skeet is forweanlyfry a qualified heating insfalhrlservice technician, ,Refer to the htttallsfion and Operatienhlanual far your reference. Have this unit serviced/inspected by a qualified service technician, at least annually. Failure to comply with the above could result in severe personal injury, death, or substantial property damage. CLEARANCES Measure and record (inches) the service clearances from the nearest obstruction (min. 24" required for service): Front: 12 L Side: 5.5" Top: 54" Rear: 19" R Side: 16" Comments/Corrections needed for service clearances: General Job Notes: START-UP PERFORMED BY: Company: Shamrock Sales Name: Phone: Brandon Pease 303-399-9181 START-UP APPROVED BY: Company: Shamrock Sales Name: Gregg Gibbs Phone: 303-399-9181 High EffleiensyWater Maim And Boilers — The information on this form verifies operation of the Lochinvar product only. — This does not imply other system components or overall system operation is certified. Component and system verification should be performed by the designated commissioning agent or installing contractor. Save and Submit Form Internal Use: SIO a: Routed: Tech: APP, fl Denied:0 Job Name: Address: FT XL Big Mountain Ranch Main House START-UP 2147 Ute Stock Dr. City: Rifle OVERVIEW Retrofit New Project ' 0 0 How many units are installed at this location? Boiler(s): 2 Water Heater(s): 2 Inspect gas pipe, regulator and meter sizing. Is it sized correctly ® y for the Btu/Hr requirement? N ST: Go 7-p: 81650 GAS SUPPLY Gas Pipe Dia. (in.): 1 Is there an inlet gas lockup regulator on the supply? If Yes, is it ten feel upstream from the appliance? 0 ® N Record in. of water column - Static Pressure: 12.5 Dynamic Pressure: 7.5 Comments/Corrections needed for gas supply, water or electricity: –Water-heaters-•a•r-e-�IdP--at-rn–l:jl}72 _._._____---_.____ VENTING (Select the venting option being used): O Vertical Direct Vent - two pipe vertical termination aCommon Vent - two or more units piped to the same flue O Horizontal Direct Vent - two pipe sidewall termination 0 Concentric Vent Vertical - single pipe vertical termination O Concentric Vent Horizontal - single pipe sidewall termination O Vertical Vent w/ sidewall Air -- single pipe vertical termination w/ single pipe combustion air supply O Vertical Vent w/ Room Air - single pipe vertical termination O Horizontal Vent w/ Room Air - single pipe sidewall termination Heat Exchanger condensate piped to: Neutralizer Kit lO Drain 0 Air Inlet Air Inlet Total Eqv. Dia. (in.): Material: Length (ft.): 4 Solid core Sch 40 PVC 30 Flue Material: Solid core Sch 40 PVC Flue Dia. (in.): 4 Total Eqv. Length (ft.): 30 Comments/Corrections needed for air inlet or vent piping: Send completed form to: Email: 2tech@Lochinvar.com Fax: (615)882-2963 Mall': Service•DeptiLuuhinvai 300 Maddox Simpson Pkwy. Lebanon, TN 37090 CHECKLIST Model Number: FTX600N Serial Number: 1841 112123822 7-2-2019 Start-up Date: WATER & ELECTRICAL Water Pipe Dia. (in.): 2 At full fire, read and record - Inlet Temp: 122 Outlet Temp: 133 Delta T: 11 Supply VAC: 120 Ttl Amp draw: COMBUSTION Low' Fire: o, 4.6 CO ppm 17.5 CO, 10.2 High Fire: 0, CO ppm CO2 5.3 143 9.4 WARNING This Startup Sheet is for wtsonly by a qualified heating Installer/service technician. Refer to theLrltali ition andOperathmt Manaalforyour reference. Have this unit serviced/inspected by a qualified service technician, at least annually. Failure to comply with the above could result in severe personal injury, death, or substantial property damage. CLEARANCES Measure and record (inches) the service clearances from the nearest obstruction (min. 24" required for service): Front: 12" L Side: 16" Rear: 19n R Side: 7.5" Comments/Corrections needed for service clearances: Top: 30" General Job Notes: START-UP PERFORMED BY: Shamrock Sales Company: Name: Phone: Brandon Pease 303-399-9181 START-UP APPROVED BY; Company: Shamrock Sales Gregg Gibbs 303-399-9181 High Efficiency \►herr Heaters and Railer% — The information on this form verifies operation of the Lochinva product only. — This does not imply other system components or overall system operation is certified. Component and system verification should be performed by the designated tomsniss ionin5 Beni or installing rnntractor. Save and Submit Form Internal Use: SfO g. Routed: Tech: App: ❑ Denied:❑