HomeMy WebLinkAboutEngineer's Field Report 06.21.2010ODDO ENGINEERING, INC. FIELD REPORT Job: McPherson Residence, Garfield County, Colorado Project No.: 2800-42 Date: June 21, 2010 Location: On Site Present: Robert A. Oddo, P.E., Oddo Engineering Adam McPherson Field Observation Notes: oddo 2 engineering 1. The spacing and installation of the engineered roof trusses are acceptable. The 2x cantilever ladder framing at the gable ends are acceptable. Install pressure blocking at the end of the 2x ladder framing, every other rafter, at the Master Bedroom roof similar to every where else. 2. The welded steel shear plate connection at the W10 x 54 to W14 x 61 is acceptable at grid 6 and H upper level. 3. Install LSL blocking between the floor joist per detail 8/S4.2 along grid F, upper level. 4. Install a minimum of three (3) 3/4 "diameter all thread, drill and epoxy, 5" embedment as shown in the enclosed detail, at the (3) 11 7/8ML support at grid 8 and 0, Main Level. Bob2010/McPhersonFR# 1 713 Cooper Avenue • Suite 200 • Glenwood Springs, CO 81601 (970) 945-1006 • Fax (970) 945-2966 • E -Mail bob@oddogws.com ODDO ENGINEERING, INC. 713 Cooper Avenue, Suite 200 Glenwood Springs, CO 81601 (970) 945-1006 Fax 945-2966 Job Title Job No V- SOLO by 0Z40 date 61 P. iQk'd by date Subject Page of 11