HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-12-19-6082
Jonah Frank
Detached Garage — Manufactured Steel Building
6023 County Road 214, New Castle
1) ALL WORK SHALL COMPLY WITH 2015 I.B.C., I.R.C., & 2009 I.E.C.C., AND MANUFACTURER'S
INSTALLATION REQUIREMENTS. THIS STRUCTURE IS ALSO SUBJECT TO GARFIELD COUNTY'S
"RURAL" ZONE DISTRICT REQUIREMENTS.
2) IMPROVEMENTS SHALL COMPLY WITH ALL APPLICABLE ITEMS CONTAINED IN ATTACHED
"GARFIELD COUNTY BUILDING REQUIREMENTS". NUMBERED REFERENCES NOTED ON THE
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) BUILDING IS APPROVED AS A DETACHED RESIDENTIAL ACCESSORY STRUCTURE.
4) A LOT IMPROVEMENT CERTIFICATE SEALED BY A COLORADO PROFESSIONAL LICENSED
SURVEYOR 15 REQUIRED AT FOUNDATION INSPECTION TO VERIFY THAT STRUCTURE IS IN
COMPLIANCE WITH BUILDING SETBACK REQUIREMENTS.
5) AN OPEN -HOLE SOILS REPORT PREPARED BY A COLORADO LICENSED PROFESSIONAL
ENGINEER IS REQUIRED AT FOOTING INSPECTION TO VERIFY 3,000 P.S.F. MINIMUM SOILS
BEARING CAPACITY AS PER STRUCTURAL ENGINEER'S REQUIREMENTS. PROVIDE COPY OF
REPORT FOR BUILDING INSPECTOR REVIEW AT FOUNDATION INSPECTION.
6) ALL HIGH-STRENGTH BOLTING AND FIELD WELDING REQUIRES SPECIAL INSPECTOR PER THE
SPECIAL INSPECTIONS PROVISIONS OF I.B.C., CHAPTER 17. PROVIDE APPROVAL REPORT AT
FRAME INSPECTION.
7) A MINIMUM OF (1) WALK-THROUGH SIDE -HINGED DOOR (MIN. SIZE: 36" WIDE X 80" HT.)
IS REQUIRED FOR EGRESS.
8) REFER TO ATTACHED ITEMS #59, 62, 63, 64, 65 & 71 FOR HEATING/MECHANICAL SYSTEMS
REQUIREMENTS. MECHANICAL VENTILATION AT BATHROOM AS PER ITEM #57.
9) BUILDING SHALL COMPLY WITH 2009 I.E.C.C. FOR EXTERIOR INSULATION AND THERMAL
ENVELOPE REQUIREMENTS, INCLUDING INSTALLATION OF RIGID INSULATION AT CONCRETE
SLAB EDGE ALONG FOUNDATION PERIMETER AS PER I.E.C.C., SECTION 402.2.8.
10) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD.
ELECTRICAL ROUGH -IN APPROVAL 15 REQUIRED AT FRAME INSPECTION. ELECTRICAL FINAL
APPROVAL IS REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.