Loading...
HomeMy WebLinkAboutObservation of Excavation 10.23.2019Kumar & Associates, Inc. Geotechnical and Materials Engineers and Environmental 5cientisIs 5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com An Employee Owned Company www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado October 23, 2019 Kuersten Construction Attn: John Kuersten P.O. Box 1530 Rifle, Colorado 81650 joliuerstenconstruction.com Project No. 19-7-603 Subject: Observation of Excavation, New Modular Building and Scales, Garfield County Landfill, Anvil Points Road, County Road 256, West of Rifle, Garfield County, Colorado Dear John: As requested, a representative of Kumar & Associates, Inc. observed the excavation at the subject site on October 15, 2019 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. The services were performed in accordance with our agreement for professional engineering services to Kuersten Construction, dated October 9, 2019. The proposed modular building will be a one story wood frame structure. The scales and building will be supported on footings designed for an assumed allowable soil bearing pressure of 3,000 psf. At the time of our visit to the site, the foundation excavations had been cut in one level 31/2 feet below the adjacent ground surface. The soils exposed in the bottom of the excavations consisted of relatively dense, silty sandy gravel with cobbles (matrix supported, alluvial fan soils). The subgrade had been compacted. The results of a gradation analysis performed on a sample of silty sandy gravel with cobbles (minus 5 -inch fraction) obtained from the site are presented on Figure 1. No free water was encountered in the excavations and the soils were slightly moist to moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 3,000 psf can be used for support of the proposed modular building and scales with a risk of settlement mainly if the bearing soils are wetted. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose disturbed soils in footing areas should be compacted or removed and the bearing level extended down to the Kuersten Construction October 23, 2019 Page 2 undisturbed natural soils. The bearing soils should be protected against frost and concrete should not be placed on frozen soils. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls acting as retaining structures should also be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 45 pcf for on-site gravel soil as backfill. A perimeter foundation drain should be provided to prevent temporary buildup of hydrostatic pressure behind the crawlspace walls and prevent wetting of the lower level. Structural fill placed within floor slab areas can consist of the on-site soils excluding rock larger than 6 inches compacted to at least 95% of standard Proctor density at a moisture content near optimum. Backfill placed around the structure should be compacted and the surface graded to prevent ponding within at least 10 feet of the building. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, Kumar & Associates, Inc. Daniel E. Hardin, P. . Rev. by: SLP , DEH/kac Q f-. Attachment Figure 1 `' 'ratia'tion_T st Results Kumar & Associates, Inc. Project No. 19-7-603 HYDROMETER ANALYSIS SIEVE ANALYSIS TIME REAOINOS 29 HRS 7 NRS 100 s•r. MIN 15 MIN GOYIM 1914IM. 48111 1M11 !RM Tow /SO /1C R30 0 6 it?. U.S. STANDARD SER/ES 90 60 70 60 50 40 30 20 10 0 .Ca I 002 I I Wizl r oil CLEAR Sa5AR£ OPENING!. 3/6' 3/4" i t/2' 3' 4 t. _ I 1.471s1 .160 .500 1 I I .1.600 I IIIr. I I .1 11111 1 R 2 0.36 4.76 6 DIAMETER OF PARTICLES IN MILLIMETERS 19 10 20 30 40 50 60 70 80 90 I I !_II.11 100 35.1 76.2 137 202 162 1 CLAY TO SILT GRAVEL 60 X LIQUID LIMIT SAND GRAVEL FINE SAND 22 X I MEDIUM COARSE FINE COARSE COBBLES PLASTICITY INDEX SILT AND CLAY 18 X SAMPLE OF: Silty Sandy Gravel with Cobbles FROM: Footing Grade These teal results apply only to the samples which were Tested. The feellnp. roporl shall noI be reproduced, esoept In full, wlthoul the pen approval 01 Kutner & Assoaiolss, Ina. Slays analysts lnl1ny is performed In eecard0nee wlh ASTM 06913. ASTM D7928, ASTM C136 and/or ASTM D1140. 19-7-603 Kumar & Associates GRADATION TEST RESULTS Fig. 1