Loading...
HomeMy WebLinkAboutObservation of Excavation 06.20.2019K+A Kumar & Associates, l c. Geatethr's,al and Materials Engineers end Environmental Scientists 5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com An Employee Owned Company www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado June 20, 2019 Kuersten Construction Attn: John Kuersten P.O. Box 1530 Rifle, Colorado 81650 ohn cukwnt•"ci , • ^ i on.coin Subject: Dear John: dR. lli "Mit 30. Project No. 19-7-382 Observation of Excavation, Proposed Shop, 4520 County Road 214 (Peach Valley Road), Garfield County, Colorado As requested, a representative of Kumar & Associates, Inc. observed the excavation at the subject site on June 17, 2019 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. The services were performed in accordance with our agreement for professional engineering services to Kuersten Construction, dated June 17, 2019. The proposed shop will be a one-story wood frame structure, 40' by 50', with a slab -on -grade floor. Foundations were designed based on an assumed allowable soil bearing pressure of 1,500 psf. At the time of our visit to the site, the foundation excavation had been cut in two levels from 21/2 to 10 feet below the adjacent ground surface. The step in grade between levels was 11A feet down to the south. The soils exposed in the bottom of the excavation consisted primarily of medium stiff, sandy silty clay. Weathered shale bedrock was exposed in the northwest, deepest corner of the excavation. Results of swell -consolidation testing performed on samples of the sandy silty clay taken from the site, shown on Figures 1 and 2, indicate the soils are moderately compressible under conditions of loading and wetting. No free water was encountered in the excavation and the soils were moist. Based on our initial observations and the apparent compressibility of the clay soils versus the incompressible shale bedrock, we recommended that at least 2 feet of the clay soils be removed from below footing grade and be replaced with structural fill consisting of imported %-inch road base. The road base should be compacted to at least 98% of the maximum standard Proctor density at a moisture content near optimum and extend at least 1 foot beyond the footing edge. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural bedrock or at least 2 feet of structural fill in the clay soil area designed for an allowable soil bearing pressure of 1,500 psf can be used for support of the proposed shop. The clay soils tend to compress under loading and there could be some post -construction settlement of the foundation on the order ofY2 to 1 inch. Footings should be a minimum width of 18 inches for continuous walls and 2 feet for columns. Kuersten Construction June 20, 2019 Page 2 Loose and disturbed soils in footing areas should be removed and the bearing level extended down to the undisturbed bedrock or structural fill. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should also be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 50 pcf for on-site soil as backfill. A perimeter foundation drain should be provided to prevent temporary buildup of hydrostatic pressure behind retaining portions of the foundation walls and prevent wetting of the lower level. Structural fill placed within floor slab areas can consist of imported granular soils compacted to at least 95% of standard Proctor density at a moisture content near optimum. Backfill placed around the structure should be compacted and the surface graded to prevent ponding within at least 10 feet of the building. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, Kumar & Associates, Inc. cf Daniel E. Hardin, P. t 0 24443 z. Rev. by: SLP gi'• 1:jYlj�� •'4 4 DEH/kac attachments Figures 1 and 2 — Swell -Consolidation Test Results cc: Glenwood Structural & Civil, Inc. — Adolfo Gorra (gsciasopris_ ix_I) Kumar & Associates, Inc. Project No. 19-7-382 F_1p3Z197392-0 CONSOLIDATION - SWELL 1 0 -1 — 2 — 3 — 4 — 5 — 6 ,new t x ...,w* oh* a.a a h. . im*. t..ted Tho tret4 report . nW/ not a rep , .amt an fWt. without 11* wntt.n oppro.ot el Nvn or cog M..eeiet... he. $.ell Can.ataMn Intim partmww7 in euordoew. with Ana D-454. SAMPLE OF: Sandy Silty Clay FROM: Footing Grade North Side WC = 16.9 %, DD = 108 pcf NO MOVEMENT UPON WETT1 NG 19-7-382 f 1.0 APPLIED PRESSURE — K$F fD 400 Kumar & Associates SWELL—CONSOLIDATION TEST RESULT Fig. 1 CONSOLIDATION - SWELL -10 SAMPLE OF: Sandy Silty Clay FROM: Footing Grade Southeast Corner WC = 17.1 %, DD = 104 pcf ADDITIONAL COMPRESSION UNDER CONSTANT PRESSURE DUE TO WETTING ib... teal nvuh, tippy a"% to tn• N mart ah▪ em not Wird.+ nproduct.& unapt In fWl..IlhaulIhe.r$ti.n opproroi opoof %ammo, and Abrader.. InC SY.9 pen.eedellon I101.6 pMofln.tl In e aeefdonu o?tl ASN D-4646. 1.0 APPLIED PRESSURE - KSF 10 100 19-7-382 Kumar & Associates SWELL -CONSOLIDATION TEST RESULT Fig. 2