HomeMy WebLinkAboutCorrection Notice 02.04.2020Garfield County Community Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 Phone (970) 945-8212 PERMIT #5686 CORRECTION NOTICE Project Address 74 Sundance Trl. Call for re -inspection. fl$50.00 re -inspection fee must be paid prior to re -inspections. I have inspected this work and have found the following corrections are required: Framing inspection incomplete due to corrections listed below Add anchor bolts within 12" of splice of plate Sister studs in laundry room Provide letter from engineer for holes in TJI in laundry room Add nail pattern to three pack Ivl Add hangers per plans Third party special inspection for structural steel Four pac Ivl require bolt pattern per manufacturer spects Verify TJI rafter to wall connection- manufacturer specs or engineer Test upper flues Finish radon pipe run Add straps at header Inspected by: Matt M Provost Date 2-4-20 YOU ARE HEREBY NOTIFIED THAT THE ABOVE CORRECTION MUST BE INSPECTED BEFORE COVERING. When corrections have been made, please call for a new inspection. 970-945-1377 x 1621