HomeMy WebLinkAboutCorrection Notice 02.04.2020Garfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Phone (970) 945-8212
PERMIT #5686
CORRECTION
NOTICE
Project Address 74 Sundance Trl.
Call for re -inspection.
fl$50.00 re -inspection fee must be paid prior to re -inspections.
I have inspected this work and have found the following corrections are required:
Framing inspection incomplete due to corrections listed below
Add anchor bolts within 12" of splice of plate
Sister studs in laundry room
Provide letter from engineer for holes in TJI in laundry room
Add nail pattern to three pack Ivl
Add hangers per plans
Third party special inspection for structural steel
Four pac Ivl require bolt pattern per manufacturer spects
Verify TJI rafter to wall connection- manufacturer specs or engineer
Test upper flues
Finish radon pipe run
Add straps at header
Inspected by: Matt M Provost Date 2-4-20
YOU ARE HEREBY NOTIFIED THAT THE ABOVE CORRECTION
MUST BE INSPECTED BEFORE COVERING.
When corrections have been made, please call for a new
inspection. 970-945-1377 x 1621