HomeMy WebLinkAboutPermitGarfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT -6140
Permit Type X Clew X Repair X Remodel/addition
Issue Date 03/11/2020 Expiration Date 03/11/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable.
Project Address: 2321 County Road 100, Carbondale, CO 81623 Parcel No.: 2393-364-00-272
Owner Name: Charles Cole Rev Trust Owner Phone: (97Q 379-2245
Designed Sy: Carla Ostberg with CBO, INC. Designer Phone: (970) 309-5259
Contractor: Holmes Excavation
Contractor Phone: (970) 963-2007
Number of Bedrooms 3 Minimum Tank Capacity 1,250 gal Minimum Absorption 562.5 ft2
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by CBO,
INC dated January 2, 2020. Changes must be approved by Garfield County Public Health and the
designer prior to construction.
The new OWTS will serve a two-bedroom residence plus a commercial baking kitchen that may be
converted to a bedroom in the future and consist of a 1,250 -gallon, two-compartment concrete
septic tank set level and accessible at grade with a pump in the second chamber of the tank,
followed by a 1.5" diameter manifold set level to distribute effluent to 564 square feet of Soil
Treatment Area (STA). The STA consists of 3 level 1.5 -inch diameter laterals placed on a mounded,
unlined sand filter with inspection ports at each corner of the bed. Orifice holes in the laterals are to
be 5/32 -inch diameter facing down, with orifice shields, drilled 3 feet on -center along the laterals.
Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or Its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have heen reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of t stem ill be issued.
I sued By: Garfield County Environmental Health
Department
03/11/2020
Date